BACKGROUND: The rapidly growing knowledge regarding factors controlling tumour growth, with the new modalities of therapy acting on the biological activity of the tumours draw the attention of most cancer researches nowadays and represent a major focus for clinical oncology practice. For the detection of HER2/neu protein overexpression and gene amplification, immunohistochemistry (IHC) and in-situ hybridisation (ISH) is the recommended techniques, respectively, with high concordance between the two techniques. The current United Kingdom recommendations for HER2/neu testing are either for a two-tier system using IHC with reflex ISH testing in equivocal positive cases, or a one-tier ISH strategy. AIM: To compare the results of HER2/neu gene status in patients with breast carcinoma obtained by chromogenic in situ hybridisation with those obtained by immunohistochemistry, and to compare these results with hormonal receptors expression by immunohistochemistry and with age of patients.METHODS: Immunohistochemistry technique was used for evaluation of status of estrogen receptors (ER) and progesterone receptors (PR) and HER2/neu protein expression in 448 Iraqi patients with invasive breast carcinoma with different grades and histological types and then chromogenic in situ hybridization (CISH) technique was applied for all scores of HER2/neu to detect the gene status and compare the results in all negative, equivocal and positive cases by immunohistochemistry (IHC). The cases were referred from different centres, and IHC and CISH techniques were done in central public health laboratory in Baghdad over 28 months, from July 2013 to November 2015. A comparison of the results was made to find the relationship between HER2/neu and hormone receptors status and other clinical parameters like patients age. RESULTS: The mean age of the study cases was 49.08 years, ranging from 24 to 83 years. Of the 448 cases of breast carcinoma, 44 (9.8%) cases were of score 0 by IHC, none of them (0%) showed HER2/neu gene amplification by CISH. 71(15.8%) cases were of score 1 by IHC, 15 (21.12%) of them showed HER2/neu gene amplification by CISH, all were of low amplification. There were 306 (68.3%) cases of score 2 by IHC, of which 102 (33.33%) cases showed HER2/neu gene amplification by CISH, with 79 (25.81%) of them with low amplification and 23 (7.51%) cases with high amplification, while only one case (0.32%) remained in equivocal category. In score 3, all the 27 (6.0%) cases showed gene amplification with 12 (44.44%) cases with low amplification and 15 (55.55) cases with high amplification with overall percentage of gene amplification in score 3 of 100%. There was a significant inverse relationship between hormone receptors (ER and PR) status and HER2/neu gene amplification. No significant relationship was found between the patient’s age and HER2/neu gene amplification.CONCLUSION: Although immunohistochemistry is a widely used, less expensive and reliable test, we strongly advice performance of chromogenic in situ hybridization in assessment of HER2/neu gene status in all cases diagnosed with breast carcinoma as significant number of cases that were reported as negative by immunohistochemistry showed positive amplification by chromogenic in situ hybridization and can get benefit from anti-HER2 targeted treatments.
In this paper Zener diode was manufactured using ZnO-CuO-ZnO/Si heterojunction structure that used laser induced plasma technique to prepare the nanofilms. Six samples were prepared with a different number of laser pulses, started with 200 to 600 pulses on ZnO tablet with fixed the number of laser pulses on CuO tablet at 300 pulses. The pulse energy of laser deposited was 900mJ using ZnO tablet and 600mJ using CuO tablet. All prepared films shown good behavior as Zener diode when using porous silicon as substrate.
The rapid development of telemedicine services and the requirements for exchanging medical information between physicians, consultants, and health institutions have made the protection of patients’ information an important priority for any future e-health system. The protection of medical information, including the cover (i.e. medical image), has a specificity that slightly differs from the requirements for protecting other information. It is necessary to preserve the cover greatly due to its importance on the reception side as medical staff use this information to provide a diagnosis to save a patient's life. If the cover is tampered with, this leads to failure in achieving the goal of telemedicine. Therefore, this work provides an in
... Show MoreKE Sharquie, AA Noaimi, HA Al-Mudaris, Journal of Cosmetics, Dermatological Sciences and Applications, 2012 - Cited by 6
Heat transfer around a flat plate fin integrated with piezoelectric actuator used as oscillated fin in laminar flow has been studied experimentally utilizing thermal image camera. This study is performed
for fixed and oscillated single and triple fins. Different substrate-fin models have been tested, using fins of (35mm and 50mm) height, two sets of triple fins of (3mm and 6mm) spacing and three frequencies
applied to piezoelectric actuator (5, 30 and 50HZ). All tests are carried out for (0.5 m/s and 3m/s) in subsonic open type wind tunnel to evaluate temperature distribution, local and average Nusselt number (Nu) along the fin. It is observed, that the heat transfer enhancement with oscillation is significant compared to without o
This study is unique in this field. It represents a mix of three branches of technology: photometry, spectroscopy, and image processing. The work treats the image by treating each pixel in the image based on its color, where the color means a specific wavelength on the RGB line; therefore, any image will have many wavelengths from all its pixels. The results of the study are specific and identify the elements on the nucleus’s surface of a comet, not only the details but also their mapping on the nucleus. The work considered 12 elements in two comets (Temple 1 and 67P/Churyumoy-Gerasimenko). The elements have strong emission lines in the visible range, which were recognized by our MATLAB program in the treatment of the image. The percen
... Show MoreBackground: Giant middle cerebral artery (MCA) aneurysms are surgically challenging lesions. Because of the complexity and variability of these aneurysms, a customized surgical technique is often needed for each case. In this article, we present a modified clip reconstruction technique of a ruptured complex giant partially thrombosed middle cerebral artery aneurysm.
Case description: The aneurysm was exposed using the pterional approach. Following proximal control, the aneurysm sac was decompressed. Then, we applied permanent clips to reconstruct the aneurysm neck. The configuration of the aneurysm mandated a tailored clipping pattern to account for resi
... Show MoreThis study presents a practical method for solving fractional order delay variational problems. The fractional derivative is given in the Caputo sense. The suggested approach is based on the Laplace transform and the shifted Legendre polynomials by approximating the candidate function by the shifted Legendre series with unknown coefficients yet to be determined. The proposed method converts the fractional order delay variational problem into a set of (n + 1) algebraic equations, where the solution to the resultant equation provides us the unknown coefficients of the terminated series that have been utilized to approximate the solution to the considered variational problem. Illustrative examples are given to show that the recommended appro
... Show MoreThe researchers have discovered weaknesses in the rotational phase of the 100-meter freestyle event, including a lack of proper movement direction and control of biomechanical variables necessary for swimmers to achieve high rotational accuracy, which leads to outperforming competitors. The objective of this study was to investigate the effect of using a laser device on improving the performance of the rotational phase among swimmers on the Iraqi national team. The experimental approach was conducted on a sample of 6 swimmers, representing 100% of the target population. The researchers concluded that the utilization of a proposed laser device in the rotational phase resulted in positive differences in biomechanical variables, contri
... Show MoreIn the analysis of multiple linear regression, the problem of multicollinearity and auto-correlation drew the attention of many researchers, and given the appearance of these two problems together and their bad effect on the estimation, some of the researchers found new methods to address these two problems together at the same time. In this research a comparison for the performance of the Principal Components Two Parameter estimator (PCTP) and The (r-k) class estimator and the r-(k,d) class estimator by conducting a simulation study and through the results and under the mean square error (MSE) criterion to find the best way to address the two problems together. The results showed that the r-(k,d) class estimator is the best esti
... Show More