Preferred Language
Articles
/
SRanZIkBVTCNdQwCBonq
VOICE ACTIVATION VISUALIZATION FOR ECHOCARDIOGRAPH AND 3D ANGIOGRAPHIC IMAGES IN SURGERY
...Show More Authors

In some cases, surgeons need to navigate through the computer system for reconfirmation patients’ details and unfortunately surgeons unable to manage both computer system and operation at the same time. In this paper we propose a solution for this problem especially designed for heart surgeon, by introducing voice activation system with 3D visualization of Angiographic images, 2D visualization of Echocardiography processed video and selected patient’s details. In this study, the processing, approximation of the 3D angiography and the visualization of the 2D echocardiography video with voice recognition control are the most challenging work. The work involve with predicting 3D coronary three from 2D angiography image and also image enhancement which utilize the median filtering, morphological opening and contrast improvement and heart boundaries detection. With 3D reconstruction of 2D angiography images, the system was able to display 3D coronary tree, with voice activation. The system was able to rotate, zoom in and out the 3D image, the 2D echocardiography video and display patient’s information that needed by the surgeon while doing heart surgery. Development of this system is useful for surgeons, where they can navigate the system using voice commands instead of keyboard and mouse. Medical practitioners also can facilitate more the angiogram and echocardiograph images. With this system, it can help and ease the work of surgeons in analyzing and processing the medical images especially in-vivo procedure.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 10 2015
Journal Name
British Journal Of Mathematics & Computer Science
The Use of Gradient Based Features for Woven Fabric Images Classification
...Show More Authors

View Publication
Crossref
Publication Date
Tue Feb 28 2023
Journal Name
Iraqi Journal Of Science
Hybrid Techniques with Support Vector Machine for Improving Artifact Ultrasound Images
...Show More Authors

     The most common artifacts in ultrasound (US) imaging are reverberation and comet-tail. These are multiple reflection echoing the interface that causing them, and result in ghost echoes in the ultrasound image. A method to reduce these unwanted artifacts using a Otsu thresholding to find region of interest (reflection echoes) and output applied to median filter to remove noise. The developed method significantly reduced the magnitude of the reverberation and comet-tail artifacts. Support Vector Machine (SVM) algorithm is most suitable for hyperplane differentiate. For that, we use image enhancement, extraction of feature, region of interest, Otsu thresholding, and finally classification image datasets to normal or abnormal image.

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Oct 30 2023
Journal Name
Iraqi Journal Of Science
New Class of Conjugate Gradient Methods for Removing Impulse Noise Images
...Show More Authors

The conjugate coefficient optimal is the very establishment of a variety of  conjugate gradient methods. This paper proposes a new class coefficient of conjugate gradient (CG) methods for impulse noise removal, which is based on the quadratic model. Our proposed method ensures descent independent of the accuracy of the line search and it is globally convergent under some conditions, Numerical experiments are also presented for the impulse noise removal in images.

View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Aug 06 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Calculating Techniques for The Contrast of Images Which Have Different Illuminations
...Show More Authors

      The distortion, which occurs to the image often affects the existing amount of information, weakens its sharpness, decreases its contrast, thus leads to overlapping details of the various regions, and decreases image resolution. Test images are used to determine the image quality and ability of different visual systems, as we depended in our study on test image, half black and half white. Contrast was studied in the petition so as to propose several new methods for different contrasts in the edge of images where the results of technical differences would identify contrast image under different lighting conditions.

View Publication Preview PDF
Publication Date
Thu Mar 01 2012
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The role of tax exemption in attracting foreign investment and the possibility of activation in the Iraqi economy
...Show More Authors

The tax exemption, whether wholly or partially, and for an unlimited duration of the investment or for a limited period of few years, is one of the encouraging things to the flow of foreign capital. And if necessary, impose tax on the profits of the invested capital, the promotion requires that not be discriminatory taxes or payments in the amount of money with the need to avoid double taxation. The tax exemption is granted by the government and the feature according to the law of a natural person or legal entity seeking from the government purports to achieve a set of political goals, economic and  social development. The reduction of taxes or grants partial exemption is one of the factors that encourage attract of direct foreign i

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of 2 different techniques in second stage implant surgery
...Show More Authors

Background: Dental implant is one of the most important options for teeth replacement. In two stage implant surgery, a few options could be used for uncovering implants, scalpel and laser are both considered as effective methods for this purpose. The Aim of the study: To compare soft tissue laser and scalpel for exposing implant in 2nd stage surgery in terms of the need for anesthesia, duration of procedure and pain level assessment at day 1 and day 7 post operatively using visual analogue scale . Materials and methods: Ten patients who received bilateral implants participated after healing period completed, gingival depth over each implant was recorded and then implant(s) were exposed by either scalpel or laser with determination for th

... Show More
View Publication
Scopus (2)
Crossref (4)
Scopus Crossref
Publication Date
Wed Apr 01 2015
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Review Of surgery of VSD in Ibn Al-Nafees Teaching Hospital
...Show More Authors

Background: Ventricular septal defect (VSD) is the most commonly recognized congenital heart defect. Isolated VSDs represent about 20-30% of all congenital cardiac malformations and have a prevalence of 1- 2 % per 1,000 live births.
Objective: This study is planned to review the outcome of surgical closure of VSD at Ibn Al-Nafees Teaching Hospital (Department Cardiac Surgery) Baghdad/Iraq.
Patients and methods: This study includes 50 cases of VSD both isolated and VSD associated with other congenital malformations admitted and underwent surgical repair of age range between 3 to 28 years and weight range between 9 to 80 kg. Different type of VSD, were found and repaired whether isolated or with other associated congenital anomalies

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 01 2008
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Abdominal Operations without Nasogastric tube :A major advance in modern surgery
...Show More Authors

Background: Routine use of nasogastric tubes, after abdominal operations, is intended to hasten the return of bowel function, prevent pulmonary complications, diminish the risk of
anastomotic leakage, increase patient comfort and shorten hospital stay. Aim of this study is to evaluate the efficacy of routine nasogastric decompression after abdominal surgery, in
achieving each of the above goals.
Patients and methods:Two hundred and twelve patients having abdominal operations of any type, emergency and elective have been followed prospectively over a period of three years (1st December 2004 until end of December 2007) in Baghdad teaching hospital. Patients were randomized into two groups. Group 1 had naso

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Feb 28 2023
Journal Name
Iraqi Journal Of Science
Data Hiding in 3D Model Based on Surface Properties
...Show More Authors

    Data hiding strategies have recently gained popularity in different fields; Digital watermark technology was developed for hiding copyright information in the image visually or invisibly. Today, 3D model technology has the potential to alter the field because it allows for the production of sophisticated structures and forms that were previously impossible to achieve. In this paper, a new watermarking method for the 3D model is presented. The proposed method is based on the geometrical and topology properties of the 3D model surface to increase the security. The geometrical properties are based on computing the mean curvature for a surface and topology based on the number of edges around each vertex, the vertices

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Mon Oct 28 2019
Journal Name
Iraqi Journal Of Science
Comparative analysis of Median filter family for Removing High-Density Noise in Magnetic Resonance Images
...Show More Authors

Magnetic Resonance Imaging (MRI) is a medical indicative test utilized for taking images of the tissue points of interest of the human body. During image acquisition, MRI images can be damaged by many noise signals such as impulse noise. One reason for this noise may be a sharp or sudden disturbance in the image signal. The removal of impulse noise is one of the real difficulties. As of late, numerous image de-noising methods were produced for removing the impulse noise from images. Comparative analysis of known and modern methods of median filter family is presented in this paper. These filters can be categorized as follows: Standard Median Filter; Adaptive Median Filter; Progressive Switching Median Filter; Noise Adaptive Fuz

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref