Preferred Language
Articles
/
SBi7S5QBVTCNdQwCWATi
Molecular detection and the frequency of a pore-forming toxin in Enterococcus faecalis isolated from urinary tract infections
...Show More Authors

Background: Enterococcus faecalis is a causative agent for urinary tract infections (UTIs) in Iraq and worldwide, even though it is a commensal bacterium in human and animal intestines. It can cause different illnesses due to its ability to produce various virulence factors. A pore-forming toxin (cytolysin) is the most virulence factor in this bacterium. Objective: This study aims to molecularly investigate the frequency of cytolysin toxin among E. faecalis isolated from UTIs. Methods: A hundred and eighty urine specimens were collected from females diagnosed with UTIs. Traditional laboratory and molecular methods were used for bacterial identification and toxin detection using a modified DNA extraction method. Results: The findings revealed that 27.7% (50\180) of causative agents in UTIs were E. faecalis based on the molecular technique that targeted a housekeeping gene (ddI) with specific primers using polymerase chain reaction (PCR). Most of the isolates harboured the cytolysin toxin gene (cylLL) with a frequency rate of 92% (46\50). Conclusions: A considerable prevalence of cytolysin-positive isolates in UTIs, which is a worrying indicates of the extensive spreading of a toxic strain in UTIs. The modified method for DNA extraction in gene detection was successfully used to amplify a housekeeping gene (ddI) and a virulence gene (cylLL) for cytolysin toxin detection, and this approach can be utilised for rapid bacterial identification and gene detection in medical and research purposes with a large sample size in an inexpensive manner within a short time.

Crossref
View Publication
Publication Date
Wed Jun 30 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
ELECTROCHEMICAL PREPARATION OF A MOLECULAR IMPRINTED POLYMER ELECTRODE FOR ESTEMATION OF ASPIRIN USING TWO DIFFERENT FUNCTIONAL MONOMERS.: ELECTROCHEMICAL PREPARATION OF A MOLECULAR IMPRINTED POLYMER ELECTRODE FOR ESTEMATION OF ASPIRIN USING TWO DIFFERENT FUNCTIONAL MONOMERS.
...Show More Authors

For aspirin estimated, a molecularly imprinted polymer MIP-ASP electrodes were generated by electro-polymerization process, the electrodes were prepared by combining the template (aspirin) with (vinyl acetate (VA), 1-vinylimidizole (VIZ) as a functional monomer and N, N-methylene bisacrylamide (MBAA) as crosslinkers using benzoyl peroxide (BPO) as an initiator. The efficiency of the membrane electrodes was analyzed by differential pulse voltammetry (DPV). Four electrodes were synthesized using two different plasticizers, di-butyl sebacate (DBS), di-octyl phthalate (DOP) in PVC matrix. Scanning electron microscopy (SEM) was used to describe the generated MIP, studying the electrodes properties, the slope, detection limit, and life

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Artificial Intelligent Models for Detection and Prediction of Lost Circulation Events: A Review
...Show More Authors

Lost circulation or losses in drilling fluid is one of the most important problems in the oil and gas industry, and it appeared at the beginning of this industry, which caused many problems during the drilling process, which may lead to closing the well and stopping the drilling process. The drilling muds are relatively expensive, especially the muds that contain oil-based mud or that contain special additives, so it is not economically beneficial to waste and lose these muds. The treatment of drilling fluid losses is also somewhat expensive as a result of the wasted time that it caused, as well as the high cost of materials used in the treatment such as heavy materials, cement, and others. The best way to deal with drilling fluid losses

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Apr 27 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Using Of Interpretative Reading To Explain Resistance Mechanisms Of Klebsiella pneumoniae Isolated From U. T. I. Patients
...Show More Authors

    The aim of this study was the isolation and characterization of Klebsiella pneumonia from 160 urine samples of patients hospitalized in children hospital in AL-Ramadi Proveng during October 2006 to May 2008. Also determination of the susceptibility of K. pneumoniae against a number of antibiotics to explain resistance mechanism for these antibiotics by using interpretative reading to avoid using it in treatment.           Forty two isolates were detected as K. pneumoniae with resistance to a number of antibiotics . These isolates were  tested to determine their sensitivities to a wide number of antibiotics which included  β-lactum group and aminoglicosides

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Frequency analyses of human voice using fast Fourier transform
...Show More Authors

Quantitative analysis of human voice has been subject of interest and the subject gained momentum when human voice was identified as a modality for human authentication and identification. The main organ responsible for production of sound is larynx and the structure of larynx along with its physical properties and modes of vibration determine the nature and quality of sound produced. There has been lot of work from the point of view of fundamental frequency of sound and its characteristics. With the introduction of additional applications of human voice interest grew in other characteristics of sound and possibility of extracting useful features from human voice. We conducted a study using Fast Fourier Transform (FFT) technique to analy

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Jan 01 2014
Journal Name
International Journal Of Physics And Research
PROPERTIES OF JOVIAN RADIO BURSTS AT FREQUENCY 20.1 MHZ
...Show More Authors

In this paper, a study was made to determine the properties of Jovian radio bursts emitted at frequency 20.1MHZ. The data were provided from the Radio Jove archive for twelve years (2000-2012) for multi stations. The duration time for Long bursts (L) was (10-30) seconds and for Short bursts (S) was (10-20) seconds. The effect of radio bursts from the Sun and the galactic background were calculated at the same frequency and were found that radio bursts from the Sun will reduce the occurrence probability of Jovian radio bursts much more than radio bursts from the galactic background. The distribution of Jovian radio bursts was different; the occurrence probability with respect to the northern latitudes was more than the southern latitudes.

Publication Date
Fri Feb 17 2012
Journal Name
Smart Materials And Structures
Frequency tuning of piezoelectric energy harvesters by magnetic force
...Show More Authors

View Publication
Scopus (104)
Crossref (90)
Scopus Clarivate Crossref
Publication Date
Thu Aug 17 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The using of Punica granatum phytochemicals to control the intermediate host of urinary schistosomaisis ( Schistosoma haematobium).
...Show More Authors

The using of phytochemicals  of Punica granatum to control the

snail    of    Bulinus      truncatus     the    intermediate     hosts     of    urinary

schistosomiasis in Iraq in a laboratory study.

It  was  found that  the peel  and leave  of Punica  granatum  was

effective  to  control  the  snail  with  very  small  amount  of  different concentrations (30-50 mg/l) in the first day of the treatment.

View Publication Preview PDF
Publication Date
Sun Sep 01 2019
Journal Name
Journal Of Craniofacial Surgery
Pros and Cons of the Transconjunctival Retroseptal Approach to the Isolated Orbital Floor Fracture
...Show More Authors

To get access into the orbital floor 3 paths are commonly used which are transconjunctival, subciliary and subtarsal approaches. Each one of these approaches has its advantages and disadvantages. The study assessed the outcomes of the transconjunctival retroseptal approach, which reflects our experience in this type of surgery. Along 8 years, 26 patients received in the emergency room diagnosed with pure isolated orbital floor fractures, all of them admitted to the maxillofacial surgery department and approached by transconjunctival incision without lateral canthotomy. Three types of complications occurred: laceration of the lower eyelid, injury to the lacrimal system and entropion. All of these complications were managed accordingly with n

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
Automated breast ultrasound: A comparison study with handheld ultrasound in detection and characterization of lesions in mammographically dense breast
...Show More Authors

Background: Although mammography is a powerful screening tool in detection of early breast cancer, it is imperfect, particularly for women with dense breast, which have a higher risk to develop cancer and decrease the sensitivity of mammogram, Automated breast ultrasound is a recently introduced ultrasonography technique, developed with the purpose to standardize breast ultrasonography and overcome some limitations of handheld ultrasound, this study aims to evaluate the diagnostic efficacy of Automated breast ultrasound and compare it with handheld ultrasound in the detection and characterization of breast lesions in women with dense breasts.

Objectives:<

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
Automated breast ultrasound: A comparison study with handheld ultrasound in detection and characterization of lesions in mammographically dense breast
...Show More Authors

Background: Although mammography is a powerful screening tool in detection of early breast cancer, it is imperfect, particularly for women with dense breast, which have a higher risk to develop cancer and decrease the sensitivity of mammogram, Automated breast ultrasound is a recently introduced ultrasonography technique, developed with the purpose to standardize breast ultrasonography and overcome some limitations of handheld ultrasound, this study aims to evaluate the diagnostic efficacy of Automated breast ultrasound and compare it with handheld ultrasound in the detection and characterization of breast lesions in women with dense breasts. Objectives: To evaluate the diagnostic efficacy of Automated breast ultrasound and compare

... Show More
Crossref