Design, analysis and construction of a simple pulse duplicator system
...Show More Authors

One of the most important human diseases that need to be considered in terms of development of the medical engineering devices is cardiovascular disease which is a significant cause of death globally recently. Valvular heart disease is normally treated by restoring or altering heart valves with an artificial one. But the new prosthetic valve designs necessitate testing for durability estimate and failure method. It is significant to simulate the circulation system by the building of a pulse duplicator system. This study is stated by clarifying the parameter and implementation steps of the pulse duplicator system in which the different researchers have utilized the system and tried to explain the design steps of using this system without going into the system design by steps or what are the main part of this system and how can be implemented, tested, and developed individually. In this design, a DC motor produces, through a hydraulic piston, a flow pulse to the left ventricle chamber model, which is linked with two interchangeable prosthetic heart valves. The computer is used to control and process data from volumetric flow rate and image. The findings show that the linear displacement, the velocity of the piston and the linear acceleration regularly become significant particularly and follows a sinusoidal wave shape during one cycle, when (crank length/connecting rod length) value is equal 0.2 or less. Several sets of measured flow rate readings were obtained by using flow meter sensor YF-S201, results after calibration showed the error rate falls within permissible limits

Scopus Crossref
View Publication
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Engineering
Implementation of Power System Stabilizer Based on Conventional and Fuzzy Logic Controllers
...Show More Authors

To damp the low-frequency oscillations which occurred due to the disturbances in the electrical power system, the generators are equipped with Power System Stabilizer (PSS) that provide supplementary feedback stabilizing signals. The low-frequency oscillations in power system are classified as local mode oscillations, intra-area mode oscillation, and interarea mode oscillations. A suitable PSS model was selected considering the low frequencies oscillation in the inter-area mode based on conventional PSS and Fuzzy Logic Controller. Two types of (FIS) Mamdani and suggeno were considered in this paper. The software of the methods was executed using MATLAB R2015a package.

 

 

View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Thu Jun 25 2020
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and Characterization of Piroxicam as Self-Nano Emulsifying Drug Delivery System
...Show More Authors

Piroxicam (PIR) is a nonsteroidal anti-inflammatory drug of oxicam category, used in gout, arthritis, as well as other inflammatory conditions (topically and orally). PIR is practically insoluble in water, therefore the aim is prepare and evaluate piroxicam as liquid self-nanoemulsifying drug delivery system to enhance its dispersibility and stability. The Dispersibilty and Stability study have been conducted in Oil, Surfactant and Co-surfactant for choosing the best materials to dissolve piroxicam. The pseudo ternary phase diagrams have been set at 1:1, 2:1, 3:1 as well as 4:1 ratio of surfactants and co-surfactants, also there are 4 formulations were prepared by using various concentrations of transcutol HP, cremophore EL and triacetin

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (4)
Scopus Crossref
Publication Date
Thu Jan 01 2026
Journal Name
Journal Of Advanced Pharmacy Education And Research
Formulation and optimization of clotrimazole nail lacquer as transungual drug delivery system
...Show More Authors

Clotrimazole nail lacquer was created using this research, which also included the incorporation of two different kinds of polymers. (Eudragit RL 100 and ethyl cellulose) in various concentrations, as well as castor oil as a plasticizer, salicylic acid as a keratolytic agent, and N-acetylcysteine as a penetration enhancer. The objective was to optimize the selection of polymers and their concentrations to enhance release efficacy based on in vitro permeability experiments, while also ensuring favorable film characteristics, such as flexibility, gloss, adhesive qualities, drying time, non-volatile content, viscosity, and water resistance. Formulation F3 was selected as the superior formula considering several parameters, including excellent

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat Sep 01 2018
Journal Name
International Journal Of Applied Pharmaceutics
PREPARATION AND CHARACTERIZATION OF ECONAZOLE NITRATE INCLUSION COMPLEX FOR OCULAR DELIVERY SYSTEM
...Show More Authors

Objective: Econazole nitrate (ECZ) is one of the triazole antifungal drugs with poor aqueous solubility and dissolution rate; there is a need for enhancement of solubility. Therefore; inclusion complexation with β cyclodextrin (βCD) was performed. Methods: In this study kneading method and co-evaporation method of preparation of inclusion complex between βCD and ECZ using two molar ratios of βCD. The solubility of these complexes in isotonic saline solution and distilled water was studied. Complexes prepared by kneading method were used for the preparation of different ophthalmic gel formulas using carbomer (CB) and sodium carboxymethylcellulose (sod CMC) as a gelling agent. The release profile and the rheological behaviour of the gel w

... Show More
Scopus (8)
Scopus
Publication Date
Wed Oct 07 2020
Journal Name
College Of Islamic Sciences
: Issuance, entry into force, and cancellation of regulations in the Saudi system
...Show More Authors

Praise be to God alone, and prayers and peace be upon the one after whom there is no prophet, and after:

This is a regular judicial search for the issuance, validity, and cancellation of regulations in the Saudi system. It came in an introduction and four demands and a conclusion of the most important results, then a list of the most important sources and references, in which I presented: A brief study on the issuance of regulations in the Kingdom of Saudi Arabia and the stages that they pass through, their validity and application, and the rules that govern this system in terms of people, places and times, then canceling and amending regulations And its rulings, I referred to it to the original sources approved in this section,

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Lecture Notes In Networks And Systems
Advanced Security Technique in Presence of Open Communication System and Cyber Era
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Ieee Access
Modified Elman Spike Neural Network for Identification and Control of Dynamic System
...Show More Authors

View Publication
Scopus (31)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Sat Sep 01 2018
Journal Name
2018 11th International Conference On Developments In Esystems Engineering (dese)
Sustainability Analysis and Shear Capacity of BubbleDeck Slabs with Openings
...Show More Authors

View Publication
Crossref (5)
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
GENERATION AND TOOTH CONTACT ANALYSIS (TCA) OF HYPOID GEAR DRIVE
...Show More Authors

The present work covers the Face-Hobbing method for generation and simulation of meshing of Face hobbed hypoid gear drive. In this work the generation process of hobbed hypoid gear has been achieved by determination of the generation function of blade cutter. The teeth surfaces have been drawn depending on the simulation of the cutting process and the head cutter motion. Tooth contact analysis (TCA) of such gear drive is presented to evaluate analytically the transmission error function for concave and convex tooth side due to misalignment errors. TCA results show that the gear is very sensitive to misalignment errors and
the increasing of the gear teeth number decrease the transmission error for both concave and convex tooth sides a

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Engineering
Buckling Analysis of Composite Plates under Thermal and Mechanical Loading
...Show More Authors

Buckling analysis of composite laminates for critical thermal (uniform and linear) and mechanical loads is reported here. The objective of this work is to carry out theoretical investigation of buckling analysis of composite plates under thermomechanical loads, and experimental investigation under mechanical loads. The analytical investigation involved certain mathematical preliminaries, a study of equations of orthotropic elasticity for classical laminated plate theory (CLPT), higher order shear deformation plate theory (HSDT) , and numerical analysis (Finite element method), then the equation of motion are derived and solved using Navier method and Levy method for symmetric and anti-symmetric cross-ply and angle-ply laminated plates t

... Show More
View Publication Preview PDF