Background: Prosthodontists estimated the parallelism of the occlusal plane to different anatomical landmarks, which was somewhat arbitrary and depended mainly on their vision. The aim of this research was to assess the degree of accuracy of prosthodontists in determining the parallelism of two lines. This research was aimed to assess which technique would be more accurate for the prosthodontist to distinguish parallelism; the comparison of the occlusal plane with the interpupillary line or with the inferior border of the earlobes. Materials and methods: Twenty eight prosthodontic specialists were included in this research. Illustrations of two lines with different tilts were presented to the participants to distinguish whether parallel or not. These illustrations were divided into two groups; the first group was with lines close together, used with the earlobes and occlusal plane, and the second group was with lines farther apart, used for the interpupillary line and occlusal plane. Results: Prosthodontists were accurate to a fraction of a degree in detecting non-parallel lines. Lines closer together were evaluated more accurately than lines farther apart. Males were slightly better when the lines were closer together. Age, experience, and post graduate degrees didn’t seem to play any role in the judgment of the prosthodontist. Conclusion: Prosthodontists were very accurate and reliable in judging parallel lines. Concerning the comparison of parallel lines, earlobes were better landmarks for orienting the occlusal plane than the interpupillary line.
A simple, rapid and sensitive spectrophotometric method has been developed for the determination of captopril in aqueous solution. The method is based on reaction of captopril with 2,3-dichloro 1,4- naphthoquinon(Dichlone) in neutral medium to form a stable yellow colored product which shows maximum absorption at 347 nm with molar absorptivity of 5.6 ×103 L.mole-1. cm-1. The proposed method is applied successfully for determination of captopril in commercial pharmaceutical tablets.
A UV-Vis spectrophotometry method was developed for the determination of metoclopramide hydrochloride in pure and several pharmaceutical preparations, such as Permosan tablets, Meclodin syrups, and Plasil ampoules. The method is based on the diazotization reaction of metoclopramide hydrochloride with sodium nitrate and hydrochloric acid to yield the diazonium salt, which is then reacted with 3,5-dimethyl phenol in the presence of sodium hydroxide to form a yellow azo dye. Calibration curves were linear in the range from 0.3 to 6.5 µg/mL, with a correlation coefficient of 0.9993. The limits of detection and quantification were determined and found to be 0.18 and 0.61 µg/mL, respectively. Accuracy and precision were also determined b
... Show MoreThe research focuses on determination of best location of high elevated tank using the required head of pump as a measure for this purpose. Five types of network were used to find the effect of the variation in the discharge and the node elevation on the best location. The most weakness point was determined for each network. Preliminary tank locations were chosen for test along the primary pipe with same interval distance. For each location, the water elevation in tank and pump head was calculated at each hour depending on the pump head that required to achieve the minimum pressure at the most weakness point. Then, the sum of pump heads through the day was determined. The results proved that there is a most economical lo
... Show MoreA reliable differential pulse polarographic (DPP) method has been developed and applied for the determination of ibuprofen IBU in dosage form with dropping mercury electrode (DME) versus Ag/AgCl. The best peak was found at cathodic peak of -1.18 V in phosphate buffer at pH=4 and 0.025M of KNO3 as supporting electrolyte. In order to obtaine the highest sensitivity, instrumental and experimental parameters were examined including the type and concentration of supporting electrolyte, pH of buffer solution, pulse amplitude and voltage step time. Diffusion current showed a direct linear relationship to ibuprofen concentration in the range of (5 – 30) μg. mL-1 (2.43× 10-5
... Show MoreIodide آ in samples آ containing آ magnesium آ fluoride آ was آ determinedآ آ by using iodide selective آ electrode. آ Detecting آ the limit for iodide determination
was around آ 5x1 oآ·5آ آ M with a standard آ deviation آ ranged آ from آ آ± 0.3 to آ± 0.6.
Quantitativeآ آ methodsآ آ including; standard آ additionآ آ method, آ Potentiometric
titration آ by using a Gran plot paper for an equivalent آ point determination and a آ directآ آ methodآ&n
... Show MoreA rapid high sensitive and inexpensive economic method has been developed for the Determination of phenoxazine by using molecular spectrophotometry. The method is based on the oxidation of phenoxazine by potassium (meta)periodate in acidic medium. The oxidation conditions were selected to enhance the sensitivity and the stability of the pink colored species which shows an absorption maximum at 530 nm. The Beer’s law was obeyed for phenoxazine concentration range from 1 to 6 µg mL-1 with 0.003 µg mL-1 detection limit and provided variation coefficients between 0.4 to 1.7 %. This method was successfully applied for the determination of phenoxazine in aqueous samples
In this study, the radon gas concentration as well as the annual effective dose in leaves of the Malvasylvestris (Khabbaz) plant used in the traditional treatment and as food in Iraq, for this, it is necessary to evaluate the concentrations radon gas, which were measured using solid state nuclear track detectors (SSNTDs) CR-39 technique. The concentration and annual effective dose in samples were collected from Baghdad city ranged from minimum to maximum value 15.815 , 0.498 , 54.445 , 1.717 respectively, while the values of concentration and annual effective dose in a sample collected from Karbala are 15.297 ,0.482 . These values of concentration and annual effective dose less were compared with th
... Show MoreWireless sensor applications are susceptible to energy constraints. Most of the energy is consumed in communication between wireless nodes. Clustering and data aggregation are the two widely used strategies for reducing energy usage and increasing the lifetime of wireless sensor networks. In target tracking applications, large amount of redundant data is produced regularly. Hence, deployment of effective data aggregation schemes is vital to eliminate data redundancy. This work aims to conduct a comparative study of various research approaches that employ clustering techniques for efficiently aggregating data in target tracking applications as selection of an appropriate clustering algorithm may reflect positive results in the data aggregati
... Show More