Preferred Language
Articles
/
RxeF4Y4BVTCNdQwC2Fl0
Efficiency of osseodensification versus screw expansion technique for augmentation of narrow alveolar ridges: A comparative clinical study
...Show More Authors

Background: Alveolar ridge expansion is proposed when the alveolar crest thickness is ≤5 mm. The screw expansion technique has been utilized for many years to expand narrow alveolar ridges. Recently, the osseodensification technique has been suggested as a reliable technique to expand narrow alveolar ridges with effective width gain and as little surgical operating time as possible. The current study aimed to compare osseodensification and screw expansion in terms of clinical width gain and operating time. Materials and methods: Forty implant osteotomies were performed in deficient horizontal alveolar ridges (3–5 mm). A total of 19 patients aged 21–59 years were randomized into two groups: the screw expansion group, which involved 20 osteotomies performed by screw expander drills, and osseodensification group, which comprised 20 osteotomies achieved by osseodensification drilling technique. One millimetre below the alveolar bone crest was measured with a bone caliper at two intervals (before implant osteotomy and after implant osteotomy), and operating time was assessed. Results: Before expansion, the mean alveolar ridge width was 4.20 ± 0.71 mm in the osseodensification group and 4.52 ± 0.53 mm in the screw-expansion group. No statistically significant difference in alveolar bone width before expansion was found between the groups (P > 0.05). After the expansion of the alveolar ridge with osseodensification or screw expansion techniques, the average ridge width was 5.48 ± 0.57 mm in the osseodensification group and 5.71 ± 0.53 mm in the screw-expansion group. Difference in width gain postoperatively between the groups was 0.09 mm, which was not statistically significant (P > 0.05). According to operating time, osseodensification consumed 6.21 ± 0.55 minutes, and screw expansion required 16.32 ± 0.60 minutes for a single implant with a significant difference between the groups (P < 0.0001). Conclusion: Alveolar bone expansion by osseodensification showed comparable width gain and less surgical operating time compared with expansion by screw expansion technique.

Scopus Crossref
View Publication
Publication Date
Thu Jan 01 2009
Journal Name
Iraqi Journal Of Science, Supplement 0f 2009
THE RELATIVE QUANTUM EFFICIENCY OF ANTHRACENE SOLUTION AS A FUNCTION OF LIGHT EXPOSURE DURATION
...Show More Authors

Abstract In this paper the effect of light exposure duration on Anthracene solution in chloroform is studied. It is found that: the Anthracene solution change its color when it is exposed to light, and that its relative quantum efficiency, Φ, decreases as the light exposure duration, t, increases and this govern by following empirical equation:- Φ = 0.7918-0.0762 In (t)

Preview PDF
Publication Date
Sat Nov 01 2014
Journal Name
Iosr Journal Of Dental And Medical Sciences (iosr-jdms)
Cutaneous leishmaniasis: Comparative Techniques for Diagnosis
...Show More Authors

AR Al-Heany BSc, PKESMD MSc., PSAANBS PhD, APAANMD MSc., DDV, FICMS., IOSR Journal of Dental and Medical Sciences (IOSR-JDMS), 2014 - Cited by 14

View Publication
Publication Date
Thu Oct 20 2022
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Study the Efficiency of Poly Nicotine Amide as Anticorrosion Coating on Stainless Steel and Study Its Biological Activity
...Show More Authors

Using an electrochemical polymerization technique at room temperature, poly nicotine amide (PNA) was produced from the monomer nicotine amide (NA) in aqueous solution. The structure of polymer layer generated on the stainless steel surface (316 L) (working electrode) is investigated by Fourier Transmission Infrared Region (FT-IR). The anti-corrosion activity of polymer coating on the stainless steel (SS 316 L) is investigated by electrochemical polarization in 0.20M solution of HCl at 293-323K. The graphene -modified polymer film-coated SS had greater protection efficiency (PE percent) when compared to Nano ZnO -modified polymer film-coated SS. For the corrosion process of SS 316 L, kinetic and thermo-dynamic parameters of activatio

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Journal Of Economics And Administrative Sciences
Methods of Forecasting Credit Losses in A Sample of Iraqi Banks - A Comparative Analysis
...Show More Authors

  The general trend in Iraqi banks is focused towards the application of international financial reporting standards, especially the international financial reporting standard IFRS 9 “Financial Instruments”, in addition to the directives issued on the Central Bank of Iraq’s instructions for the year 2018 regarding the development of expected credit losses models, and not to adhere to a specific method for calculating these losses and authorizing the banks’ departments to adopt the method of calculating losses that suits the nature of the bank’s activity and to be consistent in its use from time to time. The research problem revolves around the different methodologies for calculatin

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jun 01 2024
Journal Name
Journal Of Physics: Conference Series
Study of The Effect of Concentration on The Efficiency of The Sensitive N749-TiO2 Solar Cell
...Show More Authors

In this research, we studied the effect of concentration carriers on the efficiency of the N749-TiO2 heterogeneous solar cell based on quantum electron transfer theory using a donor-acceptor scenario. The photoelectric properties of the N749-TiO2 interfaces in dye sensitized solar cells DSSCs are calculated using the J-V curves. For the 〖(CH_3)〗_3 COH solvent, the N749-TiO2 heterogeneous solar cell shows that the concentration carrier together with the strength coupling are the main factors affecting the current density, fill factor and efficiency. The current density and current increase as the concentration increases and the strength coupling increases as the N749-TiO2 heterogeneous in solar cell. However, the efficiency is more sens

... Show More
Publication Date
Mon Jun 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Relationships between the Physical and Chemical Properties of Narrow Fractions Distilled From Mixed Kirkuk and Sharki-Baghdad Crude Oils
...Show More Authors

Mixed Kirkuk and Sharki-Baghdad crude oils were distilled into narrow fractions. The range of these narrow fractions were 10oC, starting from IBP to 350oC. The total distillates from mixed Kirkuk and Sharki-Baghdad crude oils were 58.25 vol % and 44.65 vol %, respectively.The hydrocarbons compositions (paraffin, naphthene, aromatic) in light fractions starting from IBP to 250oC were determined by using PONA analysis method. The results show that the paraffin content decreases with increasing mid percent boiling point of the fraction, while the naphthene, and aromatic increase with the increase of mid percent boiling point of mixed Kirkuk and Sharki-Baghdad crude oils. Three groups of empirical equations were developed for the prediction

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 01 2025
Journal Name
Thermal Science And Engineering Progress
Active mixing strategies for energy-efficient water dispensers: Comparative experimental study of impeller and bubble injection in hot climates
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Jun 04 2017
Journal Name
Baghdad Science Journal
Improvement of the technique for the solution method of Gauss Seidel
...Show More Authors

In this paper, a new approach was suggested to the method of Gauss Seidel through the controlling of equations installation before the beginning of the method in the traditional way. New structure of equations occur after the diagnosis of the variable that causes the fluctuation and the slow extract of the results, then eradicating this variable. This procedure leads to a higher accuracy and less number of steps than the old method. By using the this proposed method, there will be a possibility of solving many of divergent values equations which cannot be solved by the old style.

View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Jan 20 2022
Journal Name
Journal Of Clinical Medicine
Comparison of the Safety and Efficacy of Laser Versus Pneumatic Intracorporeal Lithotripsy for Treatment of Bladder Stones in Children
...Show More Authors

This study aimed to compare the safety and efficacy of laser lithotripsy and pneumatic lithotripsy, the two most commonly used transurethral lithotripsy methods for treating bladder stones in children in Iraq. Between January 2013 and December 2016, 64 children with bladder stones were included in this prospective randomized study, after ethical committee approval and written consent from the children’s parents or caregivers were obtained. Patients were assigned randomly by computer software to two groups treated with either pneumatic cystolithotripsy or laser lithotripsy. A 9 Fr. semirigid ureteroscope was used to pass the lithotripter through and fragment the stone. A catheter of 8–12 Fr. was then introduced and kept in place

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Influence of Different Fabrication and Impression Techniques on the Marginal Adaptation of Lithium Disilicate Crowns (A comparative in vitro study)
...Show More Authors

Background: The marginal adaptation has a key role in the success and longevity of the fixed dental restoration, which is affected by the impression and the fabrication techniques .The objective of this in vitro study was to evaluate and compare the marginal fitness of lithium disilicate crowns using two different digital impression techniques (direct and indirect techniques) and two different fabrication techniques (CAD/CAM and Press techniques). Materials and Methods: Thirty two sound upper first premolar teeth of comparable size extracted for orthodontic reason were selected in this study .Standardized preparation of all teeth samples were carried out with modified dental surveyor to receive all ceramic crown restoration with 1 mm deep

... Show More
View Publication Preview PDF
Crossref (2)
Crossref