Background: Alveolar ridge expansion is proposed when the alveolar crest thickness is ≤5 mm. The screw expansion technique has been utilized for many years to expand narrow alveolar ridges. Recently, the osseodensification technique has been suggested as a reliable technique to expand narrow alveolar ridges with effective width gain and as little surgical operating time as possible. The current study aimed to compare osseodensification and screw expansion in terms of clinical width gain and operating time. Materials and methods: Forty implant osteotomies were performed in deficient horizontal alveolar ridges (3–5 mm). A total of 19 patients aged 21–59 years were randomized into two groups: the screw expansion group, which involved 20 osteotomies performed by screw expander drills, and osseodensification group, which comprised 20 osteotomies achieved by osseodensification drilling technique. One millimetre below the alveolar bone crest was measured with a bone caliper at two intervals (before implant osteotomy and after implant osteotomy), and operating time was assessed. Results: Before expansion, the mean alveolar ridge width was 4.20 ± 0.71 mm in the osseodensification group and 4.52 ± 0.53 mm in the screw-expansion group. No statistically significant difference in alveolar bone width before expansion was found between the groups (P > 0.05). After the expansion of the alveolar ridge with osseodensification or screw expansion techniques, the average ridge width was 5.48 ± 0.57 mm in the osseodensification group and 5.71 ± 0.53 mm in the screw-expansion group. Difference in width gain postoperatively between the groups was 0.09 mm, which was not statistically significant (P > 0.05). According to operating time, osseodensification consumed 6.21 ± 0.55 minutes, and screw expansion required 16.32 ± 0.60 minutes for a single implant with a significant difference between the groups (P < 0.0001). Conclusion: Alveolar bone expansion by osseodensification showed comparable width gain and less surgical operating time compared with expansion by screw expansion technique.
This study aims to illustrate and compare the perspectives of Ibn Sahnun and al-Kabasi about educational system. To this end, the researcher adopted the inductive-analytical approach to analyze their educational perspectives. The study included two chapters: one to give an overview of the life of Ibn Sahnun and al-Kabasi and the other to analyze their perspectives. The findings revealed Ibn Sahnun and al-Kabasi confirmed that compliance with the Islamic rules is an essential condition over all aspects. As for Ibn Sahnun pointed out to the important of teaching Quran as a basic reference and guide of Muslim daily-life skills and behaviors. On the other hand, al-Kabasi focused on the creation and religion as two-main aspe
... Show MoreCarbon nanoparticles are prepared by sonication using carbon black powder. The surface morphology of carbon black (CB) and carbon nanoparticles (CNPs) is investigated using scanning electron microscopy (SEM). The particles size ranges from 100 nm to 400 nm for CB and from 10 nm to 100 nm for CNPs. CNPs and CB are mixed with silicon glue of different ratios of 0.025, 0.2, 0.05, and 0.1 to synthesis films. The optical properties of the prepared films are investigated through reflectance and absorbance analyses. The ratio of 0.05 for CNPs and CB is the best for solar paint because of its higher solar water heater efficiency and is then added to the silicon glue . Temperature of cold water and temperature of hot water in storage tank were ta
... Show MoreAbstract Background: Augmentation cystoplasty is one of the surgical procedure for treatment of spastic neurogenic bladder that has a significant improvement in the cystometric parameters. Aim of study: The aim of this study is to describe cystometric findings pre and post augmentation cystoplasty in patients with spastic neurogenic bladder. Patients and methods: A prospective study including patients aged 6-18years with neurogenic bladder operated on for augmentation cystoplasty surgery with ilium segments due to a neurogenic bladder from the years 2020–2024. A urodynamic study was conducted before and 3 months after the surgical procedure. Non-probabilistic sample of consecutive cases. Descriptive statistics were presented using fre
... Show MoreComparative morphological study has been treated for two species of the genus Chaenorhinum (D.C.) Richb., These species were: 1. Chaenorhinum calycinum 2. Chaenorhinum rubrifolium (Robill. & cast. Ex Lam. & DC.) Fourr. The genus belong to the family Scorphulariaceae. Morphological characters has been studies for: root, stem, leaves, flowers (calyx, corolla, androcium including filaments and anthers, gynocium including ovary, style and stigma), fruits and seeds also has been characterized. Key for there two species presented using some quantitative characters. Other characters like shape of fruits and seeds were used too, and they were of a useful taxonomic value
Comparative morphological study has been treated for two species of the genus Chaenorhinum (D.C.) Richb., These species were: 1. Chaenorhinum calycinum 2. Chaenorhinum rubrifolium (Robill. & cast. Ex Lam. & DC.) Fourr. The genus belong to the family Scorphulariaceae. Morphological characters has been studies for: root, stem, leaves, flowers (calyx, corolla, androcium including filaments and anthers, gynocium including ovary, style and stigma), fruits and seeds also has been characterized. Key for there two species presented using some quantitative characters. Other characters like shape of fruits and seeds were used too, and they were of a useful taxonomic value
In this study, the effects of blending the un-branched acrylate polymer known as Poly (n-decyl acrylate), and the branched acrylate polymer known as Poly (iso-octyl acrylate), on the viscosity index (VI), and the pour point of the Iraqi base stocks 40, and 60 respectively, were investigated. Toluene was used as a carrier solvent for both polymer types. The improvement level of oils (VI, & pour point) gained by blending the oil with the acrylate derived polymers was compared with the values of (VI, and pour point) gained by blending the oil with a commercial viscosity index, and pour point improver. The commercial lubricant additive was purchased and used by Al-Daura Refineries. It consisted of an un-known olefin copolymer dissolved i
... Show MoreDoxycycline hyclate is an antibiotic drug with a broad‐spectrum activity against a variety of gram‐positive and gram‐negative bacteria and is frequently used as a pharmacological agent and as an effector molecule in an inducible gene expression system. A sensitive, reliable and fast spectrophotometric method for the determination of doxycycline hyclate in pure and pharmaceutical formulations has been developed using flow injection analysis (FIA) and batch procedures. The proposed method is based on the reaction between the chromogenic reagent (V4+) and doxycycline hyclate in a neutral medium, resulting in the formation of a yellow compound that shows maximum absorbance at 3
Pure SnSe thin film and doped with S at different percentage (0,3,5,7)% were deposited from alloy by thermal evaporation technique on glass substrate at room temperature with 400±20nm thickness .The influences of S dopant ratio on characterization of SnSe thin film Nano crystalline was investigated by using Atomic force microscopy(AFM), X-ray diffraction (XRD), energy dispersive spectroscopy (EDS), Hall Effect measurement, UV-Vis absorption spectroscopy to study morphological, structural, electrical and optical properties respectively .The XRD showed that all the films have polycrystalline in nature with orthorhombic structure, with preferred orientation along (111)plane .These films was manufactured of very fine crystalline size in the ra
... Show MoreThe present work intends to study of dc glow discharge were generated between pin (cathode) and a plate (anode) in Ar gas is performed using COMSOL were used to study electric field distribution along the axis of the discharge and also the distribution of electron density and electron temperature at constant pressure (P=.0.0mbar) and inter electrode distance (d=4 cm) at different applied voltage for both pin cathode system and plate anode and comparison with experimental results.