Preferred Language
Articles
/
RobepoYBIXToZYALnJwD
Biological treatment of hydrocarbons contaminated soil by Serratia ficaria
...Show More Authors

Petroleum is one of the most important substances consumed by man at present times, a major energy source in this century, petroleum oils can cause environmental pollution during various stages of production, transportation, refining and use, petroleum hydrocarbons pollutions ranging from soil, ground water to marine environment, become an inevitable problem in the modern life, current study focused on bioremediation process of hydrocarbons contaminants that remaining in the bottom of gas cylinders and discharged to the soil. Twenty-four bacterial isolates were isolated from contaminated soils all of them gram negative bacteria, bacterial isolates screening to investigate the ability of biodegradation of hydrocarbons, these isolates inoculated  with modified mineral salt media containing 1% hydrocarbons for five days in shaking incubator 150 rpm at 30oC. Then measured optical density by a spectrophotometer (UV–9200) at waves length 540nm, biomass, where three isolates appeared highest ability to growth than others isolates. These three bacterial isolates were diagnosed by morphological features, gram stain, microscopically examination, biochemical tests, as well as by using VITEK 2 Compact device. One of three isolates was selected and result of identification of this bacterium showed that belonged to Serretia ficaria.

Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Soils And Foundations
Studying collapse potential of gypseous soil treated by grouting
...Show More Authors

View Publication
Crossref (39)
Crossref
Publication Date
Fri Sep 16 2016
Journal Name
Journal Of Earthquake Engineering
Dynamic Response of Saturated Soil - Foundation System Acted upon by Vibration
...Show More Authors

In this study, the response and behavior of machine foundations resting on dry and saturated sand was investigated experimentally. In order to investigate the response of soil and footing to steady state dynamic loading, a physical model was manufactured to simulate steady state harmonic load at different operating frequencies. Total of 84 physical models were performed. The footing parameters are related to the size of the rectangular footing and depth of embedment. Two sizes of rectangular steel model footing were tested at the surface and at 50 mm depth below model surface. Meanwhile the investigated parameters of the soil condition include dry and saturated sand for two relative densities 30% and 80%. The response of the footing was ela

... Show More
View Publication
Crossref (25)
Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Improvement of Soil by Using Polymer Fiber Materials Underneath Square Footing
...Show More Authors

The change in project cost, or cost growth, occurs from many factors, some of which are related to soil problem conditions that may occurs during construction and/or during site investigation period. This paper described a new soil improvement method with a minimum cost solution by using polymer fiber materials having a length of (3 cm) in both directions and (2.5 mm) in thickness, distributed in uniform medium dense .
sandy soil at different depths (B, 1.5B and 2B) below the footings. Three square footings has been used (5,7.5 and 10 cm) to carry the above investigation by using lever arm loading system design for such purposes.
These fibers were distributed from depth of (0.1B) below the footing base down to the investigated dep

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jun 01 2022
Journal Name
Baghdad Science Journal
Design and Performance Investigation of a Solar- Powered Biological Greywater Treatment System in the Iraqi Climate
...Show More Authors

            The increase in population resulted in an increase in the consumption of water. The present work investigates the performance of a recycling solar- powered greywater treatment system for the purposes of irrigation, used to reduce the amount of waste grey water and reduce electricity consumption and reduce the costs of constructing large scale water treatment plants. The system consumes about 3814W per hour and provides water treatment about 1.4 m3 per day. The proposed system is designed to    residential, office and governmental buildings application. Tests are conducted in an office building at the Ministry of Science and Technology site in Baghdad. Laboratorial water samples testing analyses are co

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Adsorption of Levofloxacine Antibacterial from Contaminated Water by Non – Conventional Low Cost Natural Waste Materials
...Show More Authors

An experimental study was conducted with low cost natural waste adsorbent materials, barley husks and eggshells, for the removal of Levofloxacine (LEVX) antibacterial from synthetic waste water. Batch sorption tests were conducted to study their isothermal adsorption capacity and compared with conventional activated carbon which were, activated carbon > barley husks > eggshells with removal efficiencies 74, 71 and 42 % with adsorbents doses of 5, 5 and 50 g/L of activated carbon, barley husks, and eggshells respectively. The equilibrium sorption isotherms had been analyzed by Langmuir, Freundlich, and Sips models, and their parameters were evaluated. The experimental data were correlated well with the Langmuir model which gives the

... Show More
View Publication Preview PDF
Crossref (12)
Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Engineering
Characterization of the Geotechnical Properties of Expansive Soil Improved by Sludge Waste
...Show More Authors

Recently, a great rise in the population and fast manufacturing processes were noticed. These processes release significant magnitudes of waste. These wastes occupied a notable ground region, generating big issues for the earth and the environment. To enhance the geotechnical properties of fine-grained soil, a sequence of research projects in the lab were conducted to analyze the impacts of adding sludge waste (SW). The tests were done on both natural and mixed soil with SW at various proportions (2%, 4%, 6%, 8%, and 10%) based on the dry mass of the soil used. The experiments conducted focused on consistency, compaction, and shear strength. With the addition of 10% of SW, the values of LL and PI decreased by 29.7% and 3

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Feb 01 2013
Journal Name
Proceedings Of The Institution Of Civil Engineers - Ground Improvement
Treatment of collapse of gypseous soils by grouting
...Show More Authors

Gypseous soil is a collapsible soil, which causes large deformations in buildings that are constructed on it. Various methods have been used to minimise this effect, such as replacing the gypseous soil or using soil stabilisation (grouting or soil improvement). This study was carried out on four types of gypseous soils that have different properties and various gypsum contents. The testing was carried out on remoulded samples to evaluate the compressibility of gypseous soil under different conditions. The samples were grouted with acrylate liquid. The relationships between the injection pressure and the radius of flow, between time of injection and radius of flow, and between time and quantity of acrylate liquid are investigated on

... Show More
View Publication
Crossref (14)
Crossref
Publication Date
Wed Feb 22 2023
Journal Name
Iraqi Journal Of Science
Health Risk Assessment of Polycyclic Aromatic Hydrocarbons in Surface Soils at North Baiji City, Iraq.
...Show More Authors

Four major factories (Petroleum Refineries Company, Detergents Plant, Thermal Power Plant, and Gaseous Power Plant) are located to the north of Baiji City. They release pollutants in form of gases, liquids and solids; they find their way to the surrounding environment. To assess the environmental pollution of the area, 18 samples of surface soil distributed around the industrial establishments were collected and analyzed to determine the concentration of polycyclic aromatic hydrocarbons (PAH) components which are often targets in the environmental checking. Identification and quantification of the 16 PAHs components was accomplished using High Performance Liquid Chromatography (HPLC) had a model Shimadzu LC-10 AVP. The total concentratio

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Engineering And Applied Sciences
MODELING THE TRANSPORT OF CONTAMINANT BY WASHING PROCESS IN THE SANDY SOIL
...Show More Authors

The aim of this study is modeling the transport of industrial wastewater in sandy soil by using finite element method. A washing technique was used to remove the industrial wastewater from the soil. The washing technique applied with an efficient hydraulic gradient to help in transport of contaminant mass by advection. Also, the mass transport equation used in modeling the transport of industrial wastewater from soil includes the sorption and chemical reactions. The sandy soil samples obtained from Al-Najaf Governorate/Iraq. The wastewater contaminant was obtained from Al- Musyiebelectricity power plant. The soil samples were synthetically contaminated with four percentages of 10, 20, 30 and 40% of the contaminant and these percentages calc

... Show More
Publication Date
Mon Aug 01 2016
Journal Name
Journal Of Engineering
Investigation of Factors Influencing Dispersion of Liquid Hydrocarbons in Porous Media
...Show More Authors

An experimental work has been done to study the major factors that affect the axial dispersion of some hydrocarbons during liquid-liquid miscible displacement. Kerosene and gas oil are used as displacing phase while seven liquid hydrocarbons of high purity represent the displaced phase, three of the liquids are aromatics and the rest are of paraffinic base. In conducting the experiments, two packed beds of different porosity and permeability are used as porous media.

The results showed that the displacement process is not a piston flow, breakthrough of displacing fluids are shown before one pore volume has been injected. The processes are stable with no evidence of viscous fingering.

Dispersion model as a

... Show More
View Publication Preview PDF