Preferred Language
Articles
/
QxdiWJMBVTCNdQwCj9F7
Comparison of columnar and pixelated scintillators for small field of view hybrid gamma camera imaging
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Weakly Small Smiprime Submodules
...Show More Authors
Abstract<p>Let <italic>R</italic> be a commutative ring with an identity, and <italic>G</italic> be a unitary left <italic>R</italic>-module. A proper submodule <italic>H</italic> of an <italic>R</italic>-module <italic>G</italic> is called semiprime if whenever <italic>a ∈ R, y ∈ G, n ∈ Z</italic> <sup>+</sup> and <italic>a<sup>n</sup>y ∈ H</italic>, then <italic>ay ∈ H</italic>. We say that a properi submodule <italic>H</italic> of an <italic>R</italic>-module <italic>G</italic> is a weakly small semiprime, if whenever <ita></ita></p> ... Show More
Crossref (1)
Scopus Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Comparison of Faster R-CNN and YOLOv5 for Overlapping Objects Recognition
...Show More Authors

Classifying an overlapping object is one of the main challenges faced by researchers who work in object detection and recognition. Most of the available algorithms that have been developed are only able to classify or recognize objects which are either individually separated from each other or a single object in a scene(s), but not overlapping kitchen utensil objects. In this project, Faster R-CNN and YOLOv5 algorithms were proposed to detect and classify an overlapping object in a kitchen area.  The YOLOv5 and Faster R-CNN were applied to overlapping objects where the filter or kernel that are expected to be able to separate the overlapping object in the dedicated layer of applying models. A kitchen utensil benchmark image database and

... Show More
View Publication Preview PDF
Scopus (26)
Crossref (19)
Scopus Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
Investigation of Beta and Gamma Rays Total Interaction Cross Section and Effective Atomic Number for CR-39Nuclear Track Detector
...Show More Authors

CR-39 is a solid state nuclear track detector (SSNTD) that has been used in many research areas. In spite of the assumption that the CR-39 detectors are insensitive to beta and gamma rays, irradiation with these rays can have significant effects on the detector properties. In this study, beta and gamma rays mass attenuation coefficients μ/ρ (cm2 g-1) for the CR-39 detector have been measured using NaI(Tl) scintillation spectrometer along with a standard geometrical arrangement in the energy region of (0.546-2.274) MeV beta rays and standard gamma sources having energy 0.356, 0.5697, 0.6617 and 1.063 MeV. The total atomic cross-section (σtot), total electronic cross-section (σT E) and the effective atomic number (Zeff) of gamma rays a

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 02 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Diagnosis and localization of the maxillary impacted canines by using dental multi-slice computed tomography 3D view and reconstructed panoramic 2D view
...Show More Authors

Background: Diagnosis and treatment planning can be difficult with conventional radiographic methods as the orthodontic-surgical management of impacted canines requires accurate diagnosis and precise localization of the impacted canine and the surrounding structures. This study was aimed to localize and evaluate weather there is any differences in the diagnostic information provided by multi-slice computed tomography three dimensional volumetric CT images and two dimensional reconstructed panorama images (derived from CT) in subjects with impacted maxillary canines. Materials and Methods: Thirty patients including 24 female and 6 male with mean age of 18 years with suspected unilaterally or bilaterally impacted maxillary canines were evalu

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Discrete Mathematical Sciences &amp; Cryptography
On gamma T_pure submodules
...Show More Authors

A gamma T_ pure sub-module also the intersection property for gamma T_pure sub-modules have been studied in this action. Different descriptions and discuss some ownership, as Γ-module Z owns the TΓ_pure intersection property if and only if (J2 ΓK ∩ J^2  ΓF)=J^2 Γ(K ∩ F) for each Γ-ideal J and for all TΓ_pure K, and F in Z Q/P is TΓ_pure sub-module in Z/P, if P in Q.

View Publication
Scopus Clarivate Crossref
Publication Date
Sun Apr 30 2023
Journal Name
Al-kindy College Medical Journal
Comparison between Reference Infliximab (Remicade) and its Biosimilar (Remsima) in Patients with Ankylosing Spondylitis: A Field-based Pharmacoeconomic Study
...Show More Authors

Background: Ankylosing spondylitis is a chronic inflammatory disease that mostly involves the spine and sacroiliac joints. It is associated with a decreased quality of life. Biological medicines such as infliximab and its biosimilar are the mainstay treatments for active ankylosing spondylitis.

Objective: The study objective was to conduct a pharmacoeconomic study comparing the cost-effectiveness of the reference infliximab with its biosimilar in ankylosing spondylitis patients visiting public hospitals.

Subjects and Method: This is a two-center pharmacoeconomic study performed at two large teaching governmental hospitals in Baghdad, Iraq, which s

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (6)
Scopus Crossref
Publication Date
Mon Jun 15 2020
Journal Name
Al-academy
Kinetic diversity of the camera in the structure of the cinematographic scene: وفاء سعدي صالح
...Show More Authors

  Highlighting the role of the movement and its dramatic dimensions, as an artistic product, whether at the level of cinema or television in general, and the stages of its influence within the structure of the cinematographic scene in particular, had an effective role in the continuation of the structure of the event according to its dramatic and aesthetic process, and from this the research problem crystallized in the following question: What is How the kinetic diversity of the camera in the structure of the cinematographic scene is achieved to achieve the maximum possible benefit by extrapolating all opinions in line with the objectives of the research, the research presented and two topics and the introduction were divided, which

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 18 2016
Journal Name
Publications Of The Astronomical Society Of The Pacific
Extreme Contrast Ratio Imaging of Sirius with a Charge Injection Device
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed Oct 10 2018
Journal Name
Al-kindy College Medical Journal
Role of Diffusion-Weighted MR Imaging in Characterization of Posterior Fossa Tumors
...Show More Authors

Background: Conventional  MR imaging is essential for diagnosis and evaluation of the posterior fossa tumors  Objectives: To assess the value of diffusion weighted imaging and apparent diffusion coefficient in making distinction between different histological types of posterior fossa tumors.

Type of the study: Cross-sectional study.

Methods: Brain MRI and DWI assessed 19 patients (12 female and 7 male) with MRI diagnosis of posterior fossa tumors. absolute ADC values of contrast -enhancing solid tumor region and ADC ratio of solid tumor to ADC of normal -appearing deep White matter were compared with histological diagnosis postoperatively .The m

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 11 2018
Journal Name
Baghdad Science Journal
Thermoluminescence dosimetry of mixed neutron – gamma fields
...Show More Authors

The method of measurement dosimetry in neutron – gamma field by using CaSo4 : Dy (PTFE) disc which has a diameter of 1.3mm and thickness of 0.2mm and using hydrogenated material as a converters of neutron to recoil protons (n-p) reaction, the discs were irradiated by neutron source (241Am-Be) with flux of 4.5?105 n/cm2s for different time to obtain different dose. The TL signals, which we have been obtained by using the converters, are increases to 71%. So we can resolve the neutron and gamma in mixed field.

View Publication Preview PDF
Crossref