Preferred Language
Articles
/
QhZtW4cBVTCNdQwClUdm
Evaluation of the capability of Shatt Al-Arab River to control flood discharge
...Show More Authors

Abstract. Shatt Al-Arab River was the most important tide river in Iraq, it suffered from neglect and lack of maintenance in the past decades. The river embankment is constantly exposed to erosion processes due to several factors, one of the most important of these factors is the movement of water currents due to the tidal energy coming from the Arabian Gulf. In this study, one dimension unsteady-state model was implemented to study river flood capacity simulation by using HEC-RAS (5.0.7) software in Shatt Al Arab River and its tributaries. The data included flow rate, water level records were collected daily from 2018 to 2020 at different stations along the mentioned river and its feeders, additionally, the considered flood discharge data was taken. These records were taken as boundary conditions for calibration and verification of the model, Furthermore, it used for operation Scenarios. The calibration result shows a good agreement between observed and predicted records with minimum root mean square error (RMSE) was equal to 0.128 with suitable Roughness coefficient value 0.029. The study conclusions indicate that Shatt Al Arb river banks for the southern part were unsafe against the flood in the spring tide case. Furthermore, the maximum safe discharge was estimated about 850 m3/s.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Diagnostics of low-pressure capacitively coupled RF discharge argon plasma
...Show More Authors

Low-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue May 03 2022
Journal Name
Iraqi Journal Of Science
Study of Some Characteristics in Dielectric Barrier Discharge (DBD) System
...Show More Authors

In this present paper, an experimental study of some plasma characteristics in dielectric barrier discharge (DBD) system using several variables, such as different frequencies and using two different electrodes metals(aluminium (Al) and copper (Cu)), is represented. The discharge plasma was produced by an AC power supply source of 6 and 7 kHz frequencies for the nitrogen gas spectrum and for two different electrodes metals(Al and Cu). Optical emission spectrometer was used to study plasma properties (such as electron temperature ( ), electron number density ( ), Debye length ( ), and plasma frequency ( )). In addition, images were analysed for the plasma emission intensity at atmospheric air pressure.

Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Experimental investigation of dusty plasma characteristics in AC discharge system
...Show More Authors

In the present work, the effect of size of zinc dust particles on
AC argon discharge characteristics are investigated
experimentally. The plasma characteristics are determined by
using optical emission spectroscopy (OES) techniques. The
results illustrated that the electron temperature (Te) in the present
and absent of Zinc dust particle is reduced with increasing of
pressure. The electron temperature decreases with increasing of
Zinc dust size. Excitation temperature Tex is reduces with
increasing of Ar pressure in present and absent of zinc dust
particles. The present of Zinc dust reduce the Tex of Ar in both
Zinc dust size. The electron density increasing in the present and
absent of both zinc dust siz

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Nov 01 2016
Journal Name
Journal Of Engineering
Hydraulic Characteristics and Discharge of Canal Sluice Gate: Practical Approach
...Show More Authors

Simplifying formulas that are used for calculations and design are the aim of researchers. For present work, the approach to distinguish the flow under sluice gate was conducted in a laboratory. The extensive experimental program was done to collect fifty-four data points for both free and submerged flow conditions. The data included different discharges, gate openings, flow depths at upstream as well as the flow depths represent a tail water and at a contracted section for downstream. The collected data are analyzed according to a problematic that may encounter in the field, to present a more straightforward (but with acceptable accurate) practical features equations and charts. Based on the proposed formulas, five meth

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
Budget Programs and Performance away to enhance the control in government economic units
...Show More Authors

     The control function of important functions in the system of government for several reasons , perhaps the most important of the magnitude of spending and spending in one of the tools adopted in the implementation of the control function.                               

        Perhaps the most prominent stages of the development budget in terms of setup and use in the budget programs and performance , as specialized literature  show its importance in strengthening financial and operationl

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Using TermoDeck System for Pre-Cooling/ Heating to Control the Building Inside Conditions
...Show More Authors

In this paper, experimental study has been done for temperature distribution in space conditioned with Ventilation Hollow Core Slab (TermoDeck) system. The experiments were carried out on a model room with dimensions of (1m 1.2m 1m) that was built according to a suitable scale factor of (1/4). The temperature distributions was measured by 59 thermocouples fixed in several locations in the test room. Two cases were considered in this work,  the first one during unoccupied period at night time (without external load) and the other at day period with external load of 800W/m2 according to solar heat gain calculations during summer season in Iraq. All results confirm the use of TermoDeck system for ventilation and cooling/heat

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Iraqi Journal Of Physics
Water Quality Assessment for Tigris River Through Salah Al-Din Province, Iraq Using Remote Sensing Techniques
...Show More Authors

water quality assessment is still being done at specific locations of major concern. The use of Geographical Information System (GIS) based water quality information system and spatial analysis with Inverse Distance Weighted interpolation enabled the mapping of water quality indicators along Tigris river in Salah Al-Din government, Iraq. Water quality indicators were monitored by taking 13 river samples from different locations along the river during Winter season year 2020. Maps of 10 water quality indicators. This meant that the specific water quality indicator and diffuse pollution characteristics in the basin were better illustrated with the variations displayed along the course of the river than conventional line graphs. Creation of

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri May 20 2022
Journal Name
Eai Endorsed Transactions On Internet Of Things
APP innovation to Control Projects Risks Management during Crises
...Show More Authors

The goal of this study is to build an application that can be used in difficult cases and sudden circumstances during the pandemic and post-disaster state, which can be the development of digital risk management and mitigating the difficult impact of the epidemic through the improvement of IT and IoT that can be fine by finding initial solutions and make the world like a digital city that could be managed by the network. We provide this study to gain an overview of reasons for delayed and exceeded costs in a select of thirty Iraqi case projects by controlling the time and cost. The drivers of delay have been investigated in multiple countries/contexts. however, there is little country data available under the conditions that have ch

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Tue Nov 08 2022
Journal Name
V. International Scientific Congress Of Pure, Applied And Technological Sciences
The effect of background vacuum pressure on the length of gas discharge plasma by using Aluminum electrodes
...Show More Authors

Length of plasma generated by dc gas discharge under different vacuum pressures was studied experimentally. The cylindrical discharge tube of length 2m was evacuated under vacuum pressure range (0.1-0.5) mbar at constant external working dc voltage 1500V. It was found that the plasma length (L) increased exponentially with increasing of background vacuum air pressure. Empirical equation has been obtained between plasma length and gas pressure by using Logistic model of curve fitting. As vacuum pressure increases the plasma length increases due to collisions, ionizations, and diffusions of electrons and ions.

Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Assessment Efficiency Evaluation of Al-Diwaniya Sewage Treatment Plant in Iraq
...Show More Authors

This study aims to evaluate the performance of the sewage treatment plant in Al-Diwaniya, one of cities in the southern part in Iraq. This evaluation could be used to facilitate effluent quality assessment or optimal process control of the plant. The influent reaching the plant is considered a medium to strong in strength with BOD5/COD ratio in the range 0.23 and 0.69 which can be considered an easily degradable sewage by the biological processes performed by the activated sludge unit. The quality of the effluent was found to be higher than the Iraqi standards for disposal to water bodies. The BOD5/COD ratios of the treated sewage varied over a wide range as low of 0.13 to 1.48 indicating operational problems in the plant. Regression ana

... Show More
View Publication Preview PDF
Crossref (1)
Crossref