Abnormalities in the Lipid and lipoprotein levels are common in the general population and are considered as very important risk- factors for cardiovascular disease .In this context the effect of cholesterol, which is one of the most clinically relevant lipids is very important. Aim of the present study was to determine the levels of GLP-1 and GPCR in non- diabetic dyslipidaemic patients and compare the results with the control group, which may be used as a novel biomarker to predict heart disease in these patients. The study was also aimed to find the relationship between GLP-1 and GPCR with lipid profile and glucagon in the patient group. The study involved 90 non-diabetic dyslipidaemia patients, with 90 healthy controls. The subjects were matched by age (35-50 years) and body mass index (BMI) (28 kg/m2). Blood samples were collected from healthy controls and dyslipidaemic patients after 12-14 hours of fasting. The study was conducted between January 2015– September 2015 in the Ibn- Al Naphes hospital in Baghdad province / Iraq .Diabetic patients were exclusion from this study. BMI were determined for all student groups.FBG, Lipid Profile ,glucagon, GLP-1, GPCR was determined in the control and patient groups. The results are expressed as mean ± SEM. Student ̓s t-test was used to compare the significance of the variation between dyslipidaemia and control groups. Results showed nonsignificant elevations in BMI, FBS, and HbA1c levels in the patient group compared with the control group. There was a significant elevation in TC, TG, LDL-c, and VLDL-c levels in the patient group compared with the control group, while a significant decrease was noticed in HDL-c level in the patient group compared with the control group .There was also a significant elevation in glucagon, while a highly significant elevation in GLP-1 and GPCR levels in the patient group when compared with the control group. A significant correlation was observed between GLP-1 with TC, TG, HDL-c, and GPCR in the patient group. There was also a significant correlation between GPCR with TC, TG and HDL-c in the patient group. From this study, it is concluded that a significant increase in GLP-1and GPCR levels, in addition to their correlation with TC, TG, HDL-c and glucagon in the patient group, compared to the control group indicate that these parameters could be used as a novel biomarker to predict heart disease in these patients in future.
في هذا البحث تم تحضير المركبات المعدنية النانوية الجديدة لأيونات البلاتين 4+و الذهب 3+ مع ليكاند قاعدة مانخ جديد مشتق من السيبروفلوكساسين بطريقة الموجات فوق الصوتية. تم تشخيص المعقدات النانوية والليكاند الجديد بأستخدام تقنيات فيزيائية و كيميائية مختلفة مثل أطياف الاشعة تحت الحمراء، حيود الاشعة السينية ، المجهر الالكتروني الماسح ، المجهر الالكتروني النافذ و مجهر القوة الذرية. تم تحديد نشاط مضادات الأك
... Show MoreThe emergence of mixed matrix membranes (MMMs) or nanocomposite membranes embedded with inorganic nanoparticles (NPs) has opened up a possibility for developing different polymeric membranes with improved physicochemical properties, mechanical properties and performance for resolving environmental and energy-effective water purification. This paper presents an overview of the effects of different hydrophilic nanomaterials, including mineral nanomaterials (e.g., silicon dioxide (SiO2) and zeolite), metals oxide (e.g., copper oxide (CuO), zirconium dioxide (ZrO2), zinc oxide (ZnO), antimony tin oxide (ATO), iron (III) oxide (Fe2O3) and tungsten oxide (WOX)), two-dimensional transition (e.g., MXene), metal–organic framework (MOFs), c
... Show MoreEstimation of the unknown parameters in 2-D sinusoidal signal model can be considered as important and difficult problem. Due to the difficulty to find estimate of all the parameters of this type of models at the same time, we propose sequential non-liner least squares method and sequential robust M method after their development through the use of sequential approach in the estimate suggested by Prasad et al to estimate unknown frequencies and amplitudes for the 2-D sinusoidal compounds but depending on Downhill Simplex Algorithm in solving non-linear equations for the purpose of obtaining non-linear parameters estimation which represents frequencies and then use of least squares formula to estimate
... Show More
The research problem lies in the lack of accurate scientific perceptions concerning the reality of the communicator and the factors influencing his job. The research is aimed at introducing the communicator in the university press, clarifying the obstacles facing him, and uncovering the level of his job satisfaction and his visions of developing his work. The researcher adopted the survey method in the collection, analysis, and interpretation of the data using a questionnaire. A set of results and conclusions has been reached, most importantly are:
*The communicator performs multiple missions including writing, editing, and collecting info |
Abstract
Magnetic abrasive finishing (MAF) process is one of non-traditional or advanced finishing methods which is suitable for different materials and produces high quality level of surface finish where it uses magnetic force as a machining pressure. A set of experimental tests was planned according to Taguchi orthogonal array (OA) L27 (36) with three levels and six input parameters. Experimental estimation and optimization of input parameters for MAF process for stainless steel type 316 plate work piece, six input parameters including amplitude of tooth pole, and number of cycle between teeth, current, cutting speed, working gap, and finishing time, were performed by design of experiment
... Show MoreIn this work, plasma parameters such as, the electron temperature )Te(, electron density ne, plasma frequency )fp(, Debye length )λD(
and Debye number )ND), have been studied using optical emission spectroscopy technique. The spectrum of plasma with different values of energy, Pb doped CuO at different percentage (X=0.6, 0.7, 0.8) were recorded. The spectroscopic study for these mixing under vacuum with pressure down to P=2.5×10-2 mbar. The results of electron temperature for X=0.6 range (1.072-1.166) eV, for X=0.7 the Te range (1.024-0.855) eV and X=0.8 the Te is (1.033-0.921) eV. Optical properties of CuO:Pb thin films were determined through the optical transmission method using ultraviolet visible spectrophotometer within the ra
The present research investigates joints welding of 304L austenitic stainless steel using metal inert gas (MIG) welding method. The research explores the effect of process parameters (arc voltage, wire feed rate, and electrode wire diameter) on the mechanical properties of stainless steel. The above variables are varied respectively with 18.5, 19, 19.5 V, 116, 127, 137 mm/s, and 0.8, 1, 1.2 mm, with E308L as a filler electrode. The design matrix of the experiments was determined using the design of experiment (DOE) program Minitab 17 based on the levels of input elements used. The Taguchi orthogonal matrix methodology (Taguchi) technique was used to develop some empirical analysis for the maximum tensile strength and proper surface
... Show More