n this work, the effect of gamma rays on blood thinning drugs was studied using the drug (Aspirin), where gamma rays were spread with the drug using a radioactive source (Co60), and 15,000 grams of Aspirin were placed in the device (gamma chamber 900). The drug was subjected to different irradiation doses (5 KGy, 10 KGy, 15 KGy) and the amount of absorption of the drug was observed in the gamma for different doses and the study of x-rays. After confirming the absorption of the drug to radiation, the effect of the drug on blood thinning was calculated using the rat model and compared with the same drug and the same dose but without exposing the drug to radiation and comparing all results with the control group. The way drugs absorbed radiation and the radiation within the organism through drugs can be used to treat many incurable diseases and cancerous tumors.
This research included measuring the concentrations of natural radioactive isotopes U-238 and Th-232 and radiation dose rates for selected areas of Missan province, GR-460 system was used which has the potential to measure the concentrations of natural radioactive isotopes in (ppm) unit and measuring the radiation dose rates in μR/h unit. It was also used with the system the mobile device FH-40 which measures the radiation dose rates in units μSμ/h the measurement results showed the absence of a significant increase in the U-238 and Th-232 concentration where the concentration of isotopes of U-238 and natural Th-232 (3.35-5.46) ppm respectively it is authorized and universally accepted. In terms of radiation dose rates it ranged betwe
... Show MoreBackground: Although radiological diagnostic studies (RDS) are an important and acceptable part of medical practice, it is not without hazards. It is associated with increased risk of cancer. Unfortunately the typical and safe dose of each radiological examination is not known. Most of our knowledge of cancer risk comes from studies of survivors of those exposed to whole body radiation from atomic bomb in Hiroshima & Nagasaki, jobs associated with radiation exposure, Chernobyl survivors & patients treated with radiation therapy for cancer and other diseases.
Objectives To estimate radiation dose received by patients from diagnostic radiological examinations and lifetime
... Show MoreThe temperature distributions are to be evaluated for the furnace of Al-Mussaib power plant. Monte Carlo simulation procedure is used to evaluate the radiation heat transfer inside the furnace, where the radiative transfer is the most important process occurring there. Weighted sum of gray-gases model is used to evaluate the radiative properties of the non gray gas in the enclosure. The energy balance equations are applied for each gas, and surface zones, and by solving these equations, both the temperature, and the heat flux are found.
Good degree of accuracy has been obtained, when comparing the results obtained by the simulation with the data of the designing company, and the data obtained by the zonal method. In
... Show MoreSome maps of the chaotic firefly algorithm were selected to select variables for data on blood diseases and blood vessels obtained from Nasiriyah General Hospital where the data were tested and tracking the distribution of Gamma and it was concluded that a Chebyshevmap method is more efficient than a Sinusoidal map method through mean square error criterion.
I have studied the relationship between blood groups in humans and disease Cutaneous injury for the first time in Iraq study showed the presence of a significant statistical relationship between them leather Bmsoy in hospitals in Baghdad and its suburbs
Ketoprofen has recently been proven to offer therapeutic potential in preventing cancers such as colorectal and lung tumors, as well as in treating neurological illnesses. The goal of this review is to show the methods that have been used for determining ketoprofen in pharmaceutical formulations. Precision product quality control is crucial to confirm the composition of the drugs in pharmaceutical use. Several analytical techniques, including chromatographic and spectroscopic methods, have been used for determining ketoprofen in different sample forms such as a tablet, capsule, ampoule, gel, and human plasma. The limit of detection of ketoprofen was 0.1 ng/ ml using liquid chromatography with tandem mass spectrometry, while it was 0
... Show MoreMefenamic acid was esterified with starchwith[1:1] Molar ratio, as drug substituted with natural polymer, to prolongthe period of hydrolysis of drug polymer with other advantages. The new prodrug starch was characterized by FT-IR and UV-Visible and 1H-NMR spectroscopies. The physical properties were studied and controlled drug release was studied in different pH values at 37oC. The stability of drug was carried out by measuring the absorbance of mefenamic starch which hydrolyzed in HCl solution of pH 1.1 (artificial gastric fluid) and phosphate buffer of pH 7.4 (simulating intestinal fluid SIF) at 37oC for several days. The thermal analysis such as DSC was studied.