In this paper, turbidimetric and reversed-phase ultra-fast liquid chromatography (UFLC) methods were described for the quantitative determination of ephedrine hydrochloride in pharmaceutical injections form. The first method is based on measuring the turbidimetric values for the formed yellowish white precipitate in suspension status in order to determine the ephedrine hydrochloride concentration. The suspended substance is formed as a result of the reaction of ephedrine hydrochloride with phosphomolybdic acid which was used as a reagent. The physical and chemical characteristics of the complex were investigated. The calibration graphs of ephedrine were established by turbidity method. While the second method (UFLC) was conducted using the methanol-water (55+45, v/v) as the mobile phase with adjusted water pH 3.5. The ephedrine hydrochloride was detected and measured using UV detector at 260 nm. The linearity of ephedrine was obtained in the range of 0.09–0.39 mmol·l-1 . The detection limits (LOD) for the ephedrine hydrochloride were found to be 0.4 and 0.0044 mmol·l-1 by turbidity and UFLC, respectively. The developed methods were successfully applied for the quantitative determination of ephedrine hydrochloride in laboratory preparations (standard) and in commercial pharmaceutical injections. The two methods have given relative standard deviations (R.S.D.) in the range of 0.65–1.69 %, which indicates reasonable repeatability and high precision of both methods.
This study aimed to investigate the impact of implementing Glycetin by injection on the productive features of local Iraqi chickens. 100 female hens and 20 roosters from a local Iraqi chicken population, at age 26 weeks. The sample was divided into three groups, in addition to a control group. Each experimental group had 25 female hens, with the same procedure being performed for each individual hen, and 20 roosters, which were reared separately for the purpose of artificial insemination. The avian specimens were housed in separate enclosures, and the experimental conditions were allocated as follows: the initial condition (Control Group) did not receive any injections, whereas condit
Rotating cylinder electrode (RCE) is used . in weight loss technique , the salinity is 200000 p.p.m, temperatures are (30,5060,7080Co) . the velocity of (RCE) are (500,1500,3000 r.p.m). the water cut (30% , 50%). The corrosion rate of carbon steel increase with increasing rotating cylinder velocity. In single phase flow, an increase im rotational velocity from 500 to 1500 r.p.m, the corrosion rate increase from 6.88258 mm/y to 10.11563 mm/y respectively.
In multiphase flow, an increase in (RCE) from 500 to 1500 r.p.m leads to increase in corrosion rate from 0.786153 to 0.910327 mm/y respectively. Increasing brine concentration leads to increase in corrosion rate at water cut 30%.
Suggestion Plan for the Reclassification of U.N Publications in Central Library
the present study is designed to evaluate the effect of low level laser irradiation on the immume system when administere intravenoisly
A number of pulsed experiments have been carried out using a high-voltage circuit containing R,L, and C in certain arrangements. A spherical spark gap of steel electrodes was used as a high-current switch operated by a voltage of up to 8kV and triggered in both self-triggering and third-electrode triggering modes. Current measurements were carried out by using both current-viewing resistor and Rogowski coils designed for this purpose. Typical current waveforms have shown obvious dominating inductance effect of the circuit components in an underdamped oscillation. The behavior of the circuit impedance was studied by recording both pulsed current peaks and the charging voltages when currents of up to 2.5kA were recorded. The dur
... Show MoreAims current research to identify the mistakes coding contained in the reading first grade. Encoding knew that he had failed in Retrieval or identifying information, the researcher diagnosis of mistakes and presented to a group of teachers first grade and they have an appropriate adjustment and using the percentage shows that the agreement on the mistakes ratio and adjusted researcher recommended a set of proposals and recommendations can work out the future for the advancement of scientific level
We consider the problem of calibrating range measurements of a Light Detection and Ranging (lidar) sensor that is dealing with the sensor nonlinearity and heteroskedastic, range-dependent, measurement error. We solved the calibration problem without using additional hardware, but rather exploiting assumptions on the environment surrounding the sensor during the calibration procedure. More specifically we consider the assumption of calibrating the sensor by placing it in an environment so that its measurements lie in a 2D plane that is parallel to the ground. Then, its measurements come from fixed objects that develop orthogonally w.r.t. the ground, so that they may be considered as fixed points in an inertial reference frame. Moreov
... Show MoreAccording to so many previous studies, lack of sufficient information during prescribing steps may lead to medication errors. Thus, the presence of the clinical pharmacist during routine rounding process in the ward with intervention of patient care plan may reduce the probability of adverse drug events (ADEs).This study evaluate role of the clinical pharmacists, as a member of medical team with the physician, on ADEs and report their interventions in the internal medicine unit. This study was designed to compare between two groups of patients, those receiving care from a rounding team (physician, nurse, and clinical pharmacist) (study or intervention group with 51 patient); and those receiving c
... Show More