his study aims to determine most stable isobar from some isobaric elements with mass number (A= 50-65 & 180-195). This aim achieved by, firstly: plot mass parabolas for these isobaric family, second: calculated the atomic number for most stable isobar (ZA) value. To plot the mass parabola, the binding energy (B.E) calculated from semi empirical formula for these isobars. The mass number (A) plotted as a function to the (ZA) for each range; we get a linear relationship between them. An empirical formula for the most stable isobar has been developed from this linear dependence. From the results, we can see that mass parabolas for isobaric elements with odd mass number (A) are different from the mass parabolas of even mass number (A) isobars,
... Show MoreA comparison study was made for the reaction of triruthenium carbonyl Ru3(CO)12 with azoarene ArN=NAr . This reaction was monitored in two kinds of solvents , toluene , and n- octane , which yielded new triruthenium carbonyl complex Ru3(μ3-NAr)2(CO)9 . The reactions of azoarenes ArN=NAr with Ru3(CO)12 formed the following trinuclear compound of Ru3((μ3- NAr)2(CO)9 (Ar-C6H4Br-4) in law yield . In addition , to new isomers species of mononuclear cyclometallated of Ru(BrC6H4N-NC6H4NBr-4)2(CO)2 in different percentages . The mechanism of the reaction domenstrates that the formation of trinuclear bis arylimido complexes , and ortho metallated was , the result of cleavage of nitrogen –nitrogen bond . Monitoring this gave evidence that the rea
... Show MoreIn this paper, the dynamic of quark and anti-quark interaction has been used to study the production of photons in the annihilation process based on the theory of chromodynamic. The rate of the photon is to be calculated for charm and anti-strange interaction c→γg system with critical temperature 113 and 130 MeV and photon energy GeV/c. Here the critical temperature, strength coupling and photons energy are assumed to be affected dramatically on the rate of photons emission of state interaction c, which can form gluon possible structures and photon emission state. The decreased photons emission yields with increased strength couple of quarks reaction due to increase critical temperature from 113 MeV to 130 MeV were predicted. We
... Show MoreA new series of morpholine derivative were prepared by reacting the morpholine with ethyl chloro acetate in the presence triethylamine as an catalyst and benzene as a solvent gave the ethyl morpholin-4-ylacetate reaction with hydrazine hydrate and ethanol as a solvent gave the 2-(morpholin-4-yl)acetohydrazide gave series of Schiff base were prepared by reacting 2-(morpholin-4- yl)acetohydrazide with different aromatic aldehydes and ketons . The new series of (3-9 )were synthesis by reaction of Schiff base (10-14) with chloroacetyl chloride, triethyl amine as an catalyst and 1,4dioxane as a solvent .The chemical structures of the synthesis compound were identified by spectral methods their [ IR ,1H-NMR and 13C-NMR ].The synthesised compoun
... Show MoreThis study was designed to evaluate the effect of major surgery on thyroid hormones and thyrotropin in patient undergoing major lower abdominal surgery. The study included fifty patients scheduled for elective major lower abdominal surgery, the serum levels of T3, T4 and TSH were determined one day preoperatively, intraoperative, one day postoperatively, two days postoperatively, and rT3 was determined one day preoperatively, and one day postoperatively. We observed that the levels of (T3, T4, TSH) increased significantly (P<0.05) intraoperatively, one day postoperatively the levels of T3 and T4 reduced significantly (P<0.05), while TSH reduced not significantly (P>0.05), and two days postoperatively T4 and TSH returned to increase si
... Show MoreThe present work intends to study of dc glow discharge were generated between pin (cathode) and a plate (anode) in Ar gas is performed using COMSOL were used to study electric field distribution along the axis of the discharge and also the distribution of electron density and electron temperature at constant pressure (P=.0.0mbar) and inter electrode distance (d=4 cm) at different applied voltage for both pin cathode system and plate anode and comparison with experimental results.
سمير خلف فياض * و محسن طالب د.نوال عزت عبد اللطيف*, مجلة الهندسة والتكنولوجيا, 2010