Rheumatoid arthritis and periodontitis use analogous effector destructive procedures, in that the inflammatory cells and pro-inflammatory cytokines that drive chronic bone erosion in RA and chronic periodontal destruction in Periodontitis are alike. Periodontitis (PD) has appeared as a hazard factor in a number of health situations as rheumatoid arthritis (RA). To determine the effect of anti-tumor necrosis factor alpha biological treatment (methotrexate and Enbrel or infliximab) on periodontal status of patients having rheumatoid arthritis with periodontitis in comparison to those having periodontitis without rheumatoid arthritis and control healthy subjects and to determine the serum levels of anti-cyclic citrullinated peptide (ACCP) in these groups. Periodontal parameters used in this study were plaque index (PI), gingival index (GI), bleeding on probing (BOP) and clinical attachment level (CAL). Serum levels of anti-cyclic citrullinated peptide (ACCP) was estimated by enzyme linked immunosorbent assays (ELISA). The Blood samples were gathered from 75 patients (25 patients had rheumatoid arthritis with periodontitis, 30 patients with periodontitis only and 20 evidently healthy volunteers). The current data revealed that the median value of plaque and gingival indices were higher in the periodontitis group than in rheumatoid arthritis with periodontitis group while CAL was slightly higher in rheumatoid arthritis with periodontitis group than periodontitis group. The percentage of BOP sites were higher in periodontitis group than rheumatoid arthritis with periodontitis. The serum level of anti-cyclic citrullinated peptide was found to be higher in the periodontitis group (601.846) followed by rheumatoid arthritis with periodontitis, which had the lowest median (163.99), while the median value of ACCP in control group was (218.617), and the result was statistically non-significant difference between the study groups p> 0.05. There was no correlation between anticyclic citrullinated peptide and clinical periodontal parameters in each group except in gingival index, bleeding on probing of the periodontitis group as there was significant correlation. Patients with RA receiving biological treatment had lower anti_cyclic citrullinated peptide antibody and lower periodontal indices when compared with the other patient that not taking biological therapy. Thus, suppression of pro-inflammatory cytokines might have a beneficial effect in reducing inflammatory activity in rheumatoid arthritis disease and in minimizing the periodontal destruction of chronic periodontitis.
Two methods have been applied for the spectrophotometric determination of atropine, in
bulk sample and in dosage form. The methods are accurate, simple, rapid, inexpensive and
sensitive. The first method depending on the extraction of the formed ion-pair complex with
bromphenol blue (BPB) as a chromogenic reagent in chloroform, use phthalate buffer of pH
3.0; which showed absorbance maxima at 413 nm against reagent blank. The calibration
graph is linear in the ranges of 0.5-40 µg.mL
-1
with detection limit of 0.363µg.mL
-1
. The
second method depending on the measure of the absorbance maxima of the formed charge-transfer complex with 2,3-dichloro-5,6-dicyano-p-benzoquinone (DDQ) at 457 nm against
The technology of subsurface soil water retention (SWRT) uses a polyethylene trough that is fixed under the root zone of the plant. It is a modern technology to increase the values of water use efficiency, plant productivity and saving irrigation water by applying as little irrigation water as possible. This study work aims at improving the crop yield and water use efficiency of a cucumber plant with less applied irrigation water by installing membrane trough below the soil surface. The field experiment was conducted in the Hawr Rajab District of Baghdad Governorate in Winter 2018 for testing various trickle irrigation systems. Two agricultural treatment plots were utilized in a greenhouse for the comparison. Plot T1 has used a subsurface t
... Show MoreThe dose rate for bremsstrahlung radiation from beta particles with energy (1.710) MeV and (2.28) MeV which comes from (32P and 90Y) beta source respectively have been calculated through six materials (polyethylene, wood, aluminum, iron, tungsten and lead) for first shielding material with thickness (x=1) mm which are putting between beta sources and second shield (polyethylene, aluminum and lead) with thickness (1, 2 &4) mm have been calculated. The distance between beta source and second shield is constant (D=1) cm. This dose rate was found by program called Rad Pro Calculator (version 3.26). The results of dose rate of beta particles were plotted as a function to the atomic number (Z) for first shield materials for each
... Show MoreThe process of transporting waste from urban areas to sanitary landfill sites requires large amounts of money due to the length and distance. To address this problem, temporary transfer stations were established by the Municipality of Baghdad to reduce the cost of transportation, and for the purpose of preserving the environment in a sustainable manner, standards were set for the establishment of these stations. The two stations of Al-Karrada Municipality and Al-Shula Municipality were chosen as a case study to measure the extent of adopting and applying the standards for establishing substations locally, regionally and internationally, and the most important results were reached Which is that the transforming (regular) stations of the t
... Show MoreThis paper presents the Taguchi approach for optimization of hardness for shape memory alloy (Cu-Al-Ni) . The influence of powder metallurgy parameters on hardness has been investigated. Taguchi technique and ANOVA were used for analysis. Nine experimental runs based on Taguchi’s L9 orthogonal array were performed (OA),for two parameters was study (Pressure and sintering temperature) for three different levels (300 ,500 and 700) MPa ,(700 ,800 and 900)oC respectively . Main effect, signal-to-noise (S/N) ratio was study, and analysis of variance (ANOVA) using to investigate the micro-hardness characteristics of the shape memory alloy .after application the result of study shown the hei
... Show MoreIn recent years, the Global Navigation Satellite Services (GNSS) technology has been frequently employed for monitoring the Earth crust deformation and movement. Such applications necessitate high positional accuracy that can be achieved through processing GPS/GNSS data with scientific software such as BERENSE, GAMIT, and GIPSY-OSIS. Nevertheless, these scientific softwares are sophisticated and have not been published as free open source software. Therefore, this study has been conducted to evaluate an alternative solution, GNSS online processing services, which may obtain this privilege freely. In this study, eight years of GNSS raw data for TEHN station, which located in Iran, have been downloaded from UNAVCO website
... Show MoreThe adsorption of cephalexin.H2O from aqueous solution on attapulgite, bentonite and kaolin has been studied at the human body temperature (37.5ËšC) and at 5, 27, 47ËšC in 0.1M hydrochloric acid (pH 1.2). The value of pH 1.2 has been chosen to simulate the pH of stomach fluid. The clays show the following order: Bentonite > attapulgite > kaolin, for their activity to adsorb cephalexin.H2O. The charged clay particles can attract molecules either by electrostatic forces, for the molecules of oppositely charged, or by inducing dipole formation in the neutral molecule. The L-shaped adsorption isotherm indicated that drug molecules arrangement in a flat geometry on the clay surface. The
... Show MoreThe dose rate for bremsstrahlung radiation from beta particles with energy (1.710) MeV and (2.28) MeV which comes from (32P and 90Y) beta source respectively have been calculated through six materials (polyethylene, wood, aluminum, iron, tungsten and lead) for first shielding material with thickness (x=1) mm which are putting between beta sources and second shield (polyethylene, aluminum and lead) with thickness (1, 2 &4) mm have been calculated. The distance between beta source and second shield is constant (D=1) cm. This dose rate was found by program called Rad Pro Calculator (version 3.26). The results of dose rate of beta particles were plotted as a function to the atomic number (Z) for first shield materials for each
... Show More