This study aims to evaluate the biocompatibility of a novel filler material intended to improve the longevity of polymer systems used in prosthetics in respect of cytotoxicity and skin irritation. RTV50F silicone elastomer incorporated with various percentages of hexagonal boron nitride (H-BN) (0.1, 0.3, 0.5, 0.7, and 1 wt%) have been tested. Silicone without H-BN was utilized as the control for comparison. The in vitro cytotoxicity test includes specimens (n=18) with 10 mm in diameter and 2 mm in thickness applied directly to the normal human fibroblast cell line (NHF) and incubated for 72 hours, then 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay was used to determine the cell viability. The skin irritation test was conducted in vivo, in which specimens (n=12) with 25 mm × 25 mm dimensions were applied on the back of 5 different rabbits for 4 hours, then the skin response was evaluated after 24, 48, and 72 hours. The acquired in vitro data were statically analyzed using one-way ANOVA and post-hoc Tukey’s tests with GraphPad Prism 8, where P-value < 0.05 was considered statistically significant. The H-BN powder and silicone specimens were studied via field emission scanning electron microscopy (FE-SEM). The results revealed a negligible effect of maxillofacial silicone on cell viability after 72 hours of incubation, only one group (1wt%) showed a significant difference compared to the control group but the toxicity percentage didn’t exceed 30% of cell viability and there was no skin irritation during the in vivo test.
A field experiment was conducted during winter season of 2021 at a research station of college of agricultural engineering sciences, university of Baghdad to determine the response of active fertility percentage and seed yield and its components of faba bean (Vicia faba L. cv. Aguadulce) to distance between plants and spraying of nano and traditional boron. A Randomized Complete Block Design according to split-plots arrangement was used at three replicates. The main plots were three distances between plants (25, 35 and 45 cm), while the sub plots including spraying of distilled water only (control treatment), spraying of boron at a 100 mg L-1 and spraying of nano boron at two concentrations (1
... Show MoreBackground: Few updated retrospective histopathological-based studies in Iraq evaluate a comprehensive spectrum of oro-maxillofacial lesions. Also, there was a need for a systematic way of categorizing the diseases and reporting results in codes according to the WHO classification that helps occupational health professionals in the clinical-epidemiological approach.
Objectives: to establish an electronic archiving database according to the ICD-10 that encompasses oro-maxillofacial lesions in Sulaimani city for the last 12 years, then to study the prevalence trend and correlation with clinicopathological parameters.
Subjects and Methods: A descri
... Show MoreNuclear medicine is important for both diagnosis and treatment. The most common treatment for diseases is radiation therapy used against cancer. The radiation intensity of the treatment is often less than its ability to cause damage, so radiation must be carefully controlled. The interactions of alpha particle with matter were studied and the stopping powers of alpha particle with ovary tissue were calculated using Beth-Bloch equation, Zeigler’s formula and SRIM Software also the range and Liner Energy Transfer (LET) and ovary thickness as well as dose and dose equivalent for this particle were calculated by using Matlab language for (0.01-200) MeV alpha energy.
As modern radiotherapy technology advances, radiation dose and dose distribution have improved significantly. As part of a natural evolution, there has recently been renewed interest in therapy, particularly in the use of heavy charged particles, because these types of radiation serve theoretical advantages in all biological and physical aspects. The interactions of alpha particle with matter were studied and the stopping powers of alpha particle with Breast Tissue were calculated by using Beth-Bloch equation, Zeigler's formula and SRIM software, also the Range and Liner Energy Transfer (LET) and Breast Thickness As well as Dose and Dose equivalent for this particle were calculated by using Mat lab language for (0.01-200) MeV alpha ene
... Show MoreGeneral Directorate of Surveying is considered one of the most important sources of maps in Iraq. It produced digital maps for whole Iraq in the last six years. These maps are produced from different data sources with unknown accuracy; therefore, the quality of these maps needs to be assessed. The main aim of this study is to evaluate the positional accuracy of digital maps that produced from General Directorate of Surveying. Two different study areas were selected: AL-Rusafa and AL-Karkh in Baghdad / Iraq with an area of 172.826 and 135.106 square kilometers, respectively. Different statistical analyses were conducted to calculate the elements of positional accuracy assessment (mean µ, root mean square error RMSE, minimum and maxi
... Show MoreGeneral Directorate of Surveying is considered one of the most important sources of maps in Iraq. It produced digital maps for whole Iraq in the last six years. These maps are produced from different data sources with unknown accuracy; therefore, the quality of these maps needs to be assessed. The main aim of this study is to evaluate the positional accuracy of digital maps that produced from General Directorate of Surveying. Two different study areas were selected: AL-Rusafa and AL-Karkh in Baghdad / Iraq with an area of 172.826 and 135.106 square kilometers, respectively. Different statistical analyses were conducted to calculate the elements of positional accuracy assessment (mean µ, root mean square error RMSE, mini
... Show MoreThe mass attenuation coefficient for beta particles through pure Polyvinyl chloride (PVC) and flax fibers- reinforced PVC composite were investigated as a function of the absorber thickness and the absorber to source distance. The beta particles mass attenuation coefficients were obtained using a NaI(Tl) energy selective scintillation counter with 90Sr/ 90Y beta source having an energy range from (0.546-2.275) MeV. Pure PVC polymer samples were prepared by compacting the PVC powder in a mould at high pressure (10bar) and temperature about 140°C for 30 minutes. A hot press system was used for this process. The experimentally obtained values of mass attenuation coefficients for 90Sr and 90Y were found to be 7.72 cm2.g-1and 0.842 cm2.g-1 r
... Show More