Preferred Language
Articles
/
PBbvv4sBVTCNdQwCS9uz
Determination of Some Biochemical Parameters of Acromegalic Patients with Type 2 Diabetes Mellitus.
...Show More Authors

Background: Because of the disturbance in the pituitary gland, growth hormone (GH) secretion will be increased and, as a result, insulin-like growth factor 1 (IGF-1) secretion will be increase as well, leading to a chronic and rare disease called acromegaly disease. One of the most serious complications of acromycaly is diabetes. Insulin resistance, which causes diabetes, occurs in the body because of increased growth hormone secretion Objective: The aim of this work is to estimate some biochemical parameters. These parameters were not studied extensively in the literature such as BALP and LOX and the possibility of using LOX as a new biomarker for acromyalgic patients with diabetic. Patients and Methods: The study was performed on (25) male as patients with active acromegaly and those with type 2 diabetes mellitus, aged between (40-60) years, and (25) male aged between (40-60) years as control group. Blood was collected and serum was separated. Enzyme-linked immune sorbent assay (ELISA) technique was used to determine the GH, IGF-1, BLAP, and LOX. By using enzymatic colorimetric method (Glucose oxidase-peroxidase), fasting serum glucose (FSG) was estimated. MDA and TAC were estimated by colorimetric methods as well. Results: The results showed that there were significant differences among GH, IGF-1, FSG, BLAP, LOX, and MDA when compared between patients and control group, while TAC showed a significant decrease between patients and healthy group (p < 0.05).

Preview PDF
Quick Preview PDF
Publication Date
Tue Nov 06 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Determination of Quality Assurance for Maternal and Child Health Services in Baghdad City
...Show More Authors

Objective: To determine the quality assurance for maternal and child health care services in Baghdad City.
Methodology: A descriptive study is conducted throughout the period of November 28th 2008 to October 10th
2009. A simple random sample of (349) is selected through the use of probability sampling approach. The study
sample was divided into four groups which include (220) consumers, (35) medical staff, (72) nursing staff and (22)
organization structure (primary health care centers). Data were collected through the use of assessment tools. It was
comprised of four questionnaires and overall items included in these questionnaires are (116) items. The study
included assessment of organization structure. Data were colle

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 26 2022
Journal Name
Iraqi Journal Of Science
Potentiometric Determination of Mebeverine Hydrochloride Using Imprinted Molecular Polymer in PVC Matrix Membraneā€
...Show More Authors

Publication Date
Wed Dec 01 2010
Journal Name
Iraqi Journal Of Physics
An Improved Method for the Determination of Airplane Radial Velocity Using Doppler Shift
...Show More Authors

In this research velocity of moving airplane from its recorded digital sound is introduced. The data of sound file is sliced into several frames using overlapping partitions. Then the array of each frame is transformed from time domain to frequency domain using Fourier Transform (FT). To determine the characteristic frequency of the sound, a moving window mechanics is used, the size of that window is made linearly proportional with the value of the tracked frequency. This proportionality is due to the existing linear relationship between the frequency and its Doppler shift. An algorithm was introduced to select the characteristic frequencies, this algorithm allocates the frequencies which satisfy the Doppler relation, beside that the tra

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 27 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Spectrophotometric Determination of Clonazepam in Pure and Dosage forms using Charge Transfer Reaction
...Show More Authors

A rapid, sensitive and without extraction spectrophotometric method for determination of clonazepam (CLO) in pure and pharmaceutical dosage forms has been described. The proposed method was simply depended on charge transfer reaction between reduced CLO (n-donor) and metol (N-methyl-p-aminophenol sulfate) as a chromogenic reagent (π- acceptor). The reduced drug, with zinc and concentrated hydrochloric acid, produced a purple colored soluble charge-transfer complex with metol in the presence of sodium metaperiodate in neutral medium, which has been measured at λmax 532 nm. All the variables which affected the developed and the stability of the colored product such as concentration of reagent and oxidant, temperature and time of rea

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Fri May 01 2020
Journal Name
Journal Of Oral And Maxillofacial Surgery, Medicine, And Pathology
Multiple endocrine neoplasia type 2B: Maxillofacial finding in one case
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
International Journal Of Agricultural And Statistical Sciences
USE OF MODIFIED MAXIMUM LIKELIHOOD METHOD TO ESTIMATE PARAMETERS OF THE MULTIPLE LINEAR REGRESSION MODEL
...Show More Authors

Scopus
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
The Effect of Electrospinning Parameters on Morphological and Mechanical Properties of PAN-based Nanofibers Membrane
...Show More Authors

The electrospun nanofibers membranes (ENMs) have gained great attention due to their superior performance. However, the low mechanical strength of ENMs, such as the rigidity and low strength, limits their applications in many aspects which need adequate strength, such as water filtration. This work investigates the impact of electrospinning parameters on the properties of ENMs fabricated from polyacrylonitrile (PAN) solved in N, N-Dimethylformamide (DMF). The studied electrospinning parameters were polymer concentration, solution flow rate, collector rotating speed, and the distance between the needle and collector. The fabricated ENMs were characterized using scanning electron microscopy (SEM) to understand the surface morphology and es

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (4)
Scopus Crossref
Publication Date
Sat Mar 19 2022
Journal Name
Al-khwarizmi Engineering Journal
Effect of MIG Welding Parameters on the Mechanical Properties of AISI 304 Austenitic Stainless Steels
...Show More Authors

The present research  investigates joints welding of 304L austenitic stainless steel using metal inert gas (MIG) welding method. The research explores the effect of process parameters (arc voltage, wire feed rate, and electrode wire diameter) on the mechanical properties of stainless steel.  The above variables are varied  respectively with 18.5, 19, 19.5 V, 116, 127, 137 mm/s, and 0.8, 1, 1.2 mm, with E308L as a filler electrode. The design matrix of the experiments was determined using the design of experiment (DOE) program Minitab 17 based on the levels of input elements used. The Taguchi orthogonal matrix methodology (Taguchi) technique was used to develop some empirical analysis for the maximum tensile strength and proper surface

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Fri Oct 20 2023
Journal Name
Advances In Science And Technology Research Journal
Impact of TIG Welding Parameters on the Mechanical Properties of 6061-T6 Aluminum Alloy Joints
...Show More Authors

View Publication
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Aug 13 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Diurnal Variation of Phytoplankton and Related Ecological Parameters of One Location in Habbaniya Lake, Iraq
...Show More Authors

   The presnty study included physical , chemical  and phycological study of choosen one station in  Habbaniya lake to investigat the diurnal variation at each hour along the 24 hours . Water temperature showed clear variations and coincided with the air temperature of study , Habbaniya Water was alkaline with pH more than 7 without clear diurnal variations . Conductivity , Total hardness , Calcium and Magnesium values showed no clear varitions . Chloride and Salinity values appeared relatively stable . The data showed a relative increasing in Dissolve oxygen values during the night hours.On the other hand the alkalinity and acidity values were unstable during the 24 hours of the study. According to the quantitative s

... Show More
View Publication Preview PDF