Preferred Language
Articles
/
OhYhU4cBVTCNdQwCYEWk
Resolve partially the inner disk for Epsilon Eridani
...Show More Authors
Abstract<p>We present mid-infrared imaging observations of the debris disk around one of the main sequence star Epsilon Eridani in the Q-band at (20.5 µm) and (17.6 µm). The dust that produces emission in debris disk is spatially resolved in the inner region of the debris disk of Epsilon Eridani at distance approximately between 1.4 - 4 AU.</p><p> <bold>Method:</bold> The target has been observed Epsilon Eridani using the GTC (Gran Telescope Canaria) with CanariaCam instrument, which performs imaging in mid-IR (Q-band). To detect the disk around Epsilon Eridani star, we observed a standard star and the target star, consequently. We then measured the PSF (Point Spread Function) of our standard star to limit the radial flux profile of our target star. The images were centred to the center images before subtracted the radial flux of the standard star from the radial profile of science target to get the residual flux which is produced by the debris disk. The first important step is removing the background effect from images with contribution flux of star. For this, we calculated the standard deviation of background as well as the seeing variation during the observation to estimate the value of stellar flux residuals.</p><p> <bold>Result:</bold> The dust emission around the debris disk is spatially resolved and the size of the emission is determined. The dust detected around Epsilon Eridani is located in the same distance from the star where a giant planet has confirmed. The photometry measurements are achieved for emission 0.268 Jy and the flux of the star is 2.18 Jy.</p>
Scopus Crossref
View Publication
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
PARAMETRIC STUDY OF LAMINAR FREE CONVECTION IN INCLINED POROUS ANNULUS WITH FINS ON THE INNER CYLINDER
...Show More Authors

An experimental and numerical study has been carried out to investigate the heat transfer by natural convection in a three dimensional annulus enclosure filled with porous media (silica sand) between two inclined concentric cylinders with (and without) annular fins attached to the inner cylinder under steady state condition; The experiments were carried out for a range of modified Rayleigh number (0.2 ≤Ra*≤ 11) and extended to Ra* =500 for numerical study, annulus inclination angle of (δ = 0˚, 30˚, 60˚ and 90˚). The numerical study was to write the governing equation under an assumptions used Darcy law and Boussinesq’s approximation and then solved numerically using finite difference approximation. It was found that the averag

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Nov 15 2024
Journal Name
Iraqi Journal Of Science
Study of the Spectral Energy Distribution Model of the Protoplanetary Disk Geometric around the Brown Dwarf CFHT-BD-Tau 4
...Show More Authors

The accretion circumstellar disk of young stars and the Brown dwarf plays an essential role in the formation and evaluation of the planet. Our main work in this paper is to investigate the geometrical shape model for the protoplanetary disk around one of the Brown Dwarfs. The photometric measurements for the brown dwarf CFHT-BD-Tau 4 were extracted from the Vizier archive. We used a numerical simulation to build a model of the spectral energy distribution of our target CFHT-BD-Tau 4. The spectral energy distribution model was fitted with observational data for the brown dwarf CFHT-BD-Tau 4. A transitional disk has been assumed around CFHT-BD-Tau 4. We obtained physical properties of the two disks and the size of the gap between them

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Design and study the effect of inner bore diameter on the magnetic and optical properties of the unipolar lens
...Show More Authors

    Many designs have been suggested for unipolar magnetic lenses based on changing the width of the inner bore and fixing the other geometrical parameters of the lens to improve the performance of unipolar magnetic lenses. The investigation of a study of each design included the calculation of its axial magnetic field the magnetization of the lens in addition to the magnetic flux density using the Finite Element Method (FEM) the Magnetic Electron Lenses Operation (MELOP) program version 1 at three different values of current density (6,4,2 A/mm2). As a result, the clearest values and behaviors were obtained at current density (2 A/mm2). it was found that the best magnetizing properties, the high

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Behavior of Partially Saturated Cohesive Soil under Strip Footing
...Show More Authors

In this paper, a shallow foundation (strip footing), 1 m in width is assumed to be constructed on fully saturated and partially saturated Iraqi soils, and analyzed by finite element method. A procedure is proposed to define the H – modulus function from the soil water characteristic curve which is measured by the filter paper method. Fitting methods are applied through the program (SoilVision). Then, the soil water characteristic curve is converted to relation correlating the void ratio and matric suction. The slope of the latter relation can be used to define the H – modulus function. The finite element programs SIGMA/W and SEEP/W are then used in the analysis. Eight nodded isoparametric quadrilateral elements are used for modeling

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Feb 29 2012
Journal Name
Al-khwarizmi Engineering Journal
Natural Convection in Trapezoidal Enclosure Heated Partially from Below
...Show More Authors

Natural convection in a trapezoidal enclosure with partial heating from below and symmetrical cooling from the sides has been investigated numerically. The heating is simulated by a centrally located heat source on the bottom wall, and four different values of the dimensionless heat source length, 1/5, 2/5, 3/5, 4/5 are considered. The laminar flow field is analyzed numerically by solving the steady, two-dimensional incompressible Navier-Stokes and energy equations. The Cartesian velocity components and pressure on a collocated (non-staggered) grid are used as dependent variables in the momentum equations  discretized by finite volume method; body fitted coordinates are used to represent the trapezoidal enclosure, and grid generatio

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 01 2023
Journal Name
Journal Of Engineering
Impact of Anchored CFRP Composites on the Strengthening of Partially Damaged PC Girders
...Show More Authors

This manuscript investigated the effect of anchorage CFRP wrapping sheets, bolts, and laminate interlock on increasing the efficiency of flexural strengthening for the post-tension girder using CFRP composites techniques longitudinal laminates at the soffit for partially damaged loss of about 14.3% from its area of prestressed concrete beams, and the impact on restoring the original flexural capacity of PC girder. Mitigating delamination of the soffit of horizontal laminates (CFRP). The texture of the laminate and anchorages influenced the stress of the laminate carbon fiber, the mode of crack propagation and failure, and consequently, the beam's attitude has been investigated in this manuscript. The experimental findi

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Oct 17 2025
Journal Name
Journal Of Engineering
Parametric Study Of Laminar Free Convection In Horizontal Annulus With And Without Fins On The Inner Cylinder
...Show More Authors

View Publication
Publication Date
Sat Dec 01 2018
Journal Name
Proceedings Of International Structural Engineering And Construction
ON THE REDUCTION OF PRESTRESSING FORCE NEAR SUPPORTS IN PARTIALLY PRESTRESSED CONCRETE FLEXURAL MEMBERS
...Show More Authors

Straight tendons in pretensioned members can cause high-tensile stresses in the concrete extreme fibers at end sections because of the absence of the bending stresses due to self-weight and superimposed loads and the dominance of the moment due to prestressing force alone. Accordingly, the concrete tensile stresses at the ends of a member prestressed with straight tendons may limit the service load capacity of the member. It is therefore important to establish limiting zone in the concrete section within which the prestressing force can be applied without causing tension in the extreme concrete fibers. Two practical methods are available to reduce the stresses at the end sections due to the prestressing force. The first method based

... Show More
View Publication
Crossref
Publication Date
Sat Feb 02 2019
Journal Name
Journal Of Engineering Sciences And Technology
Partially Prestressed Concrete Beams under Limited Cycles of Repeated Loading
...Show More Authors

View Publication
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Laminar Free Convection In Horizontal Annulus Filled With Glass Beads And With Annular Fins On The Inner Cylinder
...Show More Authors

An experimental and numerical study has been carried out to investigate the heat transfer by natural convection and radiation in a two dimensional annulus enclosure filled with porous media (glass beads) between two horizontal concentric cylinders. The outer cylinders are of (100, 82 and70mm) outside diameters and the inner cylinder of 27 mm outside diameter with (or without) annular fins attached to it. Under steady state condition; the inner cylinder surface is maintained at a high temperature by applying a uniform heat flux and the outer cylinder surface at a low temperature inside a freezer. The experiments were carried out for an annulus filled with
glass beads at a range of modified Rayleigh number (4.9 ≤ Ra≤ 69), radiation

... Show More
View Publication Preview PDF
Crossref