This study aims to determine the impact of organization values as an independent variable across its dimensions (organization management values, organization mission values, relations management values, and environment management values) on achieve the strategic success which is the dependent variable and include its dimensions (environmental analysis, creative thinking, strategic decision, effective implementation, and leadership capacities). The study is conducted in the Iraq Oil Ministry. It deployed the analytical descriptive approach. It focuses on the study problem enquiries throughout addressing several principal and sub-hypothesizes in regards to cause and effect relationship. To achieve this result
... Show MorePulkhana anticline is located in Tuzhurmatu area, about 50 km SE of Kirkuk city. The study area forms a part of the Zagros Folded Zone which is situated in the unstable shelf of Iraq within the physiographic zone called Foothill Zone (in the middle of Hemrin- Makhul subzone). The north eastern limb of the anticline reaches to 50ᵒ and the dip of the south western limb reaches to 70ᵒ. The core of the structure comprises the rocks of Fat’ha Formation surrounded by rocks of Injana and Mukdadiya Formations, whereas Bai-Hasan Formation forms the slopes of the low hills surrounding the anticline. These Formations range in age from Middle Miocene to Pliocene. More than 761 readings of joint planes were collected from 20
... Show MoreWith and without the use of magnetic fields, titanium dioxide (TiO2) nanoparticles were synthesized using the hydrothermal method at extremely high temperatures and pressures. Titanium tetra isopropoxide [Ti(C12H28O4)] was used for the preparation, which was performed at pH 7 and under temperatures of 160 and 190 ˚C. UV spectroscopy, XRD crystallography, FE-SEM microscopy were used for characterizations. From UV spectroscopy, the energy gap values were clearly affected by the increase in temperature and the presence of the magnetic field. At the temperatures of 160 and 190 oC for TiO2 without magnetic field, FE-SEM microscopy images have shown an average c
... Show MoreThis work evaluates the economic feasibility of various production scenarios for the Zubair reservoir in the Kifl oil field using cash flow and net present value (NPV) calculations. The Kifl field is an exploratory field that has not yet been developed or assessed economically. The first well was drilled in 1960, and three other wells were later drilled to assess the oil accumulation, so in this research, Different production scenarios were evaluated economically. These scenarios were proposed based on the reservoir model of the Zubair formation in the field. The research methodology used QUE$TOR software to estimate capital expenditures (CapEx) and operating expenditures (OpEx) based on field-level data, production prof
... Show MoreAbstract:
The achievement of economic and social welfare for individual is the main target to all policies that adopted by all countries worldwide either were economic, social, political or others. The obtaining of education by individuals and especially the higher education is one of the most important determinates in achieving the wellbeing and lasted economic development. This is because via the higher education new fields can be opened in front of individuals in order to get adequate jobs associated with their scientific specialization. This is allowing educated individuals gain higher income that can reduce the gap of income inequality.
Thus, this paper aims to analysis the n
... Show MoreMeasurements of radon gas concentrations were carried out for 12 soil samples at 3 sampling depths (surface, 5 cm and 10 cm) collected from (4) locations in south Baghdad suburbs (Bu'aitha) using solid state nuclear track detector CR-39 and sealed can technique. Radon concentrations for surface samples were ranged from 402.2 to 1538.4 Bq.m-3 with an average 994.4 Bq.m-3. Whereas, radon concentration was ranged from 813.1to 2050.4 Bq.m-3 and from 1309.8 to 4626. 1Bq.m-3 with an average values of 1359.8 Bq.m-3 and 2338.3 Bq.m-3 for 5 cm and 10 cm depths respectively. Maximum radon level was found at the location near to the river (site S4) while the minimum radon level was f
... Show More