Elimination of phenol by sonoelctrochemical process utilizing graphite, stainless steel, and titanium anodes: optimization by taguchi approach
...Show More Authors

   Phenol is one of the worst-damaging organic pollutants, and it produces a variety of very poisonous organic intermediates, thus it is important to find efficient ways to eliminate it. One of the promising techniques is sonoelectrochemical processing. However, the type of electrodes, removal efficiency, and process cost are the biggest challenges. The main goal of the present study is to investigate the removal of phenol by a sonoelectrochemical process with different anodes, such as graphite, stainless steel, and titanium. The best anode performance was optimized by using the Taguchi approach with an L16 orthogonal array. the degradation of phenol sonoelectrochemically was investigated with three process parameters: current density (CD) (25, 50, 75, and 100 mA/cm2), time (1, 2, 3, 4 h), and phenol concentration (100, and 200 mg/l). Signal-to-noise (S/N) ratio and analysis of variance (ANOVA) were utilized to examine the impact of each factor. The optimal conditions for phenol removal were 100 mA/cm2, 100 mg/l of phenol, and 4 hours of electrolysis. Under optimal operating conditions, the phenol removal efficiency was 80.99%. The CD was the most influential factor on phenol elimination effectiveness, while the phenol concentration had the least impact.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Nov 30 2021
Journal Name
Research Journal Of Pharmacy And Technology
Diagnostic approach to Perimenopausal bleeding by Pipelle or Dilatation and Curettage
...Show More Authors

Perimenopausal bleeding, is a very common problem, which is an alarming symptom for both; women and their doctors because of the rising fears of cellular changes or tumor of endometrium. In our study we tried to prove that collecting endometrial samples using the outpatient method of Pipelle is as effective as collecting the endometrial samples in the traditional method of Dilation and Curettage (DandC) in operation theatre which necessitates general anesthesia. Ninety four patients more than 40 years old were included in the study, all of them were complaining of abnormal uterine bleeding (pregnant ladies and ladies using hormonal contraception were excluded from the study) and endometrial samples were collected first in outpatient

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Sep 04 2018
Journal Name
Al-khwarizmi Engineering Journal
Study the Effect of Cutting Parameters on Temperature Distribution and Tool Life During Turning Stainless Steel 316L
...Show More Authors

This paper is focused on studying the effect of cutting parameters (spindle speed, feed and depth of cut) on the response (temperature and tool life) during turning process. The inserts used in this study are carbide inserts coated with TiAlN (Titanum, Aluminium and Nitride) for machining a shaft of stainless steel 316L. Finite difference method was used to find the temperature distribution. The experimental results were done using infrared camera while the simulation process was performed using Matlab software package. The results showed that the  maximum difference between the experimental and simulation results was equal to 19.3 , so, a good agreement between the experimental and simulation results  was achieved. Tool life w

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Oct 10 2022
Journal Name
International Journal Of Mathematics In Operational Research
Modelling time-series process of an agricultural crop production process by EWMA quality control chart
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Tue Jan 11 2022
Journal Name
3rd International Scientific Conference Of Alkafeel University (iscku 2021)
Elimination of the broadening in X-ray diffraction lines profile for nanoparticles by using the analysis of diffraction lines method
...Show More Authors

In this research, the results of the Integral breadth method were used to analyze the X-ray lines to determine the crystallite size and lattice strain of the zirconium oxide nanoparticles and the value of the crystal size was equal to (8.2nm) and the lattice strain (0.001955), and then the results were compared with three other methods, which are the Scherer and Scherer dynamical diffraction theory and two formulas of the Scherer and Wilson method.the results were as followsScherer crystallite size(7.4nm)and lattice strain(0.011968),Schererdynamic method crystallite size(7.5 nm),Scherrer and Wilson methodcrystallite size( 8.5nm) and lattice strain( 0.001919).And using another formula for Schearer and Wilson methodwe obtain the size of the c

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Thu Jan 11 2024
Journal Name
Tropical Journal Of Pharmaceutical Research
Application of Taguchi orthogonal array in optimization of the synthesis and crystallinity of metal organic framework 5 (MOF 5)
...Show More Authors

Purpose: To use the L25 Taguchi orthogonal array for optimizing the three main solvothermal parameters that affect the synthesis of metal-organic frameworks-5 (MOF-5). Methods: The L25 Taguchi methodology was used to study various parameters that affect the degree of crystallinity (DOC) of MOF-5. The parameters comprised temperature of synthesis, duration of synthesis, and ratio of the solvent, N,N-dimethyl formamide (DMF) to reactants. For each parameter, the volume of DMF was varied while keeping the weight of reactants constant. The weights of 1,4-benzodicarboxylate (BDC) and Zn(NO3)2.6H2O used were 0.390 g and 2.166 g, respectively. For each parameter investigated, five different levels were used. The MOF-5 samples were synthesi

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Jun 01 2025
Journal Name
Chemical Engineering And Processing - Process Intensification
Wastewater treatment through a hybrid electrocoagulation and electro-Fenton process with a porous graphite air-diffusion cathode
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Jun 01 2025
Journal Name
Chemical Engineering And Processing - Process Intensification
Wastewater treatment through a hybrid electrocoagulation and electro-Fenton process with a porous graphite air-diffusion cathode
...Show More Authors

View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Jun 01 2025
Journal Name
Chemical Engineering And Processing - Process Intensification
Wastewater treatment through a hybrid electrocoagulation and electro-Fenton process with a porous graphite air-diffusion cathode
...Show More Authors

View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Dec 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Acetaminophen Residues from Wastewater by Bulk Liquid Membrane Process
...Show More Authors

   The removal of Anit-Inflammatory drugs, namely; Acetaminophen (ACTP), from wastewater by bulk liquid membrane (BLM) process using Aliquat 336 (QCl) as a carrier was investigated. The effects of several parameters on the extraction efficiency were studied in this research, such as the initial feed phase concentration (10-50) ppm of ACTP, stripping phase (NaCl) concentration (0.3,0.5,0.7 M), temperature (30-50oC), the volume ratio of feed phase to membrane phase (200-400ml/80ml), agitation speed of the feed phase (75-125 rpm), membrane stirring speed (0, 100, 150 rpm), carrier concentration (1, 5, 9 wt%), the pH of feed (2, 4, 6, 8, 10), and solvent type (CCl4 and n-Heptane). The study shows that high ext

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Physics Conference Series
Enhanced phot-respons of porous silicon photo- detectors by embedding Titanium -dioxide nano-particles
...Show More Authors

: Porous silicon (n-PS) films can be prepared by photoelectochemical etching (PECE) Silicon chips n - types with 15 (mA /cm2), in15 minutes etching time on the fabrication nano-sized pore arrangement. By using X-ray diffraction measurement and atomic power microscopy characteristics (AFM), PS was investigated. It was also evaluated the crystallites size from (XRD) for the PS nanoscale. The atomic force microscopy confirmed the nano-metric size chemical fictionalization through the electrochemical etching that was shown on the PS surface chemical composition. The atomic power microscopy checks showed the roughness of the silicon surface. It is also notified (TiO2) preparation nano-particles that were prepared by pulse laser eradication in e

... Show More