Background: Lung cancer is a common disease for patients over the age of 50 years, especially males due to smoking habits. This study aimed to compare the modulation complexity score (MCS) for the advanced treatment planning techniques which the intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). Materials and Methods: Thirty patients who had non-small lung cancerous tumors on their left side participated in this study. The range ages were 68 to 98 years, the heights were between 151 and 182cm and they having weights from 46 to 79 kg. For Each patient will create two plans dial using two different techniques, which will be Intensity Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) in the Monaco 5.1 version, and then those plans will be forwarded to the Infinity Linear Accelerator (LINAC). For the purposes of evaluation, the dose volume histogram is utilized to perform the calculation necessary to determine the dose for tumors and Organs at Risk (OAR). After that, the modulation complexity score, also known as the MCS, was determined using the multiyear collimators of the plans. Results: Showed that the mean age of males was (82.6 ± 4.93) years, while the mean age of females was (72.12 ± 3.13) years. The proportion of males was significantly higher than that of females. The female patient had a higher body mass index than the male patient. The mean height of men in this study was (172.85 ± 2.02) cm, while the mean height of women was (156.32± 1.21) cm. The coverage planning target volume (PTV) for the left lung tumor shows that the VMAT was significantly higher than the IMRT at 95%, 98%, 5%, and 2%. When comparing IMRT and VMAT for the PTV 105%, there was no discernible difference between the two. According to the statistics, the conformity and homogeneity of the dose delivered by the VMAT was noticeably higher than those delivered by the IMRT. According to the findings of the study, the MCS score for the VMAT is noticeably higher than that of the IMRT. In the case of the IMRT technique, the relationship between the MCS and the total number of monitor units was found to be positive and direct, whereas in the case of the VMAT technique, the relationship was found to be negative and inverse. Conclusions: The volumetric modulated arc therapy (VMAT) shows a better coverage and less complexity technique and could protect the heart, spinal cord, and right lung than the IMRT.
A modified water injection technique has organized by this study to improve oil recovery of the Mishrif reservoirs using polymerized alkaline surfactant water (PAS-Water) injection. It is planned to modify the existing water injection technology, first to control and balance the hazardous troublemaker reservoir facies of fifty-micron pore sizes with over 500 millidarcies permeability, along with the non-troublemaker types of less than twenty micron pore sizes with 45 to 100 millidarcies permeability. Second to control Mishrif reservoirs rock-wettability. Special core analysis under reservoir conditions of 2250 psi and 90 °C has carried out on tens of standard core plugs with heterogeneous buildup, using the proposed renewal water f
... Show MoreThis study proposes a pioneering Ethical Artificial Intelligence (EAI) framework for advancing sustainable development in Iraq by integrating eight multidimensional sustainability indicators—administrative, technological, economic, environmental, social, legal, security, and governance. Utilizing data from 60 completed development projects, the framework combines SPSS statistical analysis, the SMART-AI model, and Artificial Neural Networks (ANN) to identify key determinants of project success and failure. Results reveal a 37% project failure rate, with administrative and technological deficiencies emerging as the most influential predictors. The SMART-AI model achieved an accuracy of 91.3% using stratified k-fold cross-validation. A bilin
... Show MoreThis work presents a completely new develop an analyzer, named NAG-5SX1-1D-SSP, that is simple, accurate, reproducible, and affordable for the determination of cefotaxime sodium (CFS) in both pure and pharmaceutical drugs. The analyzer was designed according to flow injection analysis, and conducted to turbidimetric measurements. Ammonium cerium nitrate was utilized as a precipitating agent. After optimizing the conditions, the analysis system exhibited a linear range of 0.008-27 mmol. L-1 (n=29), with a limit of detection of 439.3 ng/sample, a limit of quantification of 0.4805 mg/sample, and a correlation coefficient of 0.9988. The repeatability of the responses was assessed by performing six successive injections of CFS at concentra
... Show MoreThe gas sensing properties of Co3O4and Co3O4:Y nano structures were investigated. The films were synthesized using the hydrothermal method on a seeded layer. The XRD, SEM analysis and gas sensing properties were investigated for Co3O4and Co3O4:Y thin films. XRD analysis shows that all films are polycrystalline in nature, having a cubic structure, and the crystallite size is (11.7)nm for cobalt oxide and (9.3)nm for the Co3O4:10%Y. The SEM analysis of thin films obviously indicates that Co3O4possesses a nanosphere-like structure and a flower-like structure for Co3O4:Y.The sensitivity, response time and recovery time to a H2S reducing gas were tested at different operating
... Show MoreA new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n
... Show MoreMost studies on deep beams have been made with reinforced concrete deep beams, only a few studies investigate the response of prestressed deep beams, while, to the best of our knowledge, there is not a study that investigates the response of full scale (T-section) prestressed deep beams with large web openings. An experimental and numerical study was conducted in order to investigate the shear strength of ordinary reinforced and partially prestressed full scale (T-section) deep beams that contain large web openings in order to investigate the prestressing existence effects on the deep beam responses and to better understand the effects of prestressing locations and opening depth to beam depth ratio on the deep beam performance and b
... Show MoreAutoría: Muwafaq Obayes Khudhair. Localización: Revista iberoamericana de psicología del ejercicio y el deporte. Nº. 6, 2022. Artículo de Revista en Dialnet.