Background: COVID-19 has caused a considerable number of hospital admissions in China since December 2019. Many COVID-19 patients experience signs of acute respiratory distress syndrome, and some are even in danger of dying. Objective: to measure the serum levels of D-dimer, Neutrophil-Lymphocyte count ratio (NLR), and neopterin in patients hospitalized with severe COVID-19 in Baghdad, Iraq. And to determine the cut-off values (critical values) of these markers for the distinction between the severe patients diagnosed with COVID‐19 and the controls. Materials and methods: In this case-control study, we collect blood from 89 subjects, 45 were severe patients hospitalized in many Baghdad medical centers who were diagnosed with COVID-19 infection, and 44 were apparently healthy subjects as a control. The time of collection is from September 15 th to December 31 th, 2021. The optimal cut-off points (critical values) and prognostic relevance of D-dimer, Neutrophil-Lymphocyte count ratio (NLR), and neopterin were investigated using (ROC) curves analysis. Results: In severe patients hospitalized with COVID-19 the levels of D-dimer, NLR, and neopterin were statistically significantly higher than in control participants (P< 0.005). The D-dimer, NLR, and neopterin tests have areas under the receiver operating characteristic (ROC) curves of 0.920, 0.90, and 0.74 respectively, and their critical values for the differentiation between the severe patients and control were 0.22 μg/ml, 2.56, and 3.02 nmol/L. Conclusions: D-dimer, NLR, and neopterin levels in sever COVID-19 patients were higher than control, with values of greater than 0.22μg/ml, 2.56 and 3.02nmol/L respectively was linked to a severe COVID-19infection with good sensitivity and selectivity.
CR-39 is a solid state nuclear track detector (SSNTD) that has been used in many research areas. In spite of the assumption that the CR-39 detectors are insensitive to beta and gamma rays, irradiation with these rays can have significant effects on the detector properties. In this study, beta and gamma rays mass attenuation coefficients μ/ρ (cm2 g-1) for the CR-39 detector have been measured using NaI(Tl) scintillation spectrometer along with a standard geometrical arrangement in the energy region of (0.546-2.274) MeV beta rays and standard gamma sources having energy 0.356, 0.5697, 0.6617 and 1.063 MeV. The total atomic cross-section (σtot), total electronic cross-section (σT E) and the effective atomic number (Zeff) of gamma rays a
... Show MoreThe research problem revolves around the Iraqi public's use of digital television and cinematic websites، and their importance to the academic study and society، as it examines the public's relationship with these websites، usage habits، and the reasons for their interaction with them. And for the prevalence of this phenomenon of use، it was necessary to address the intensity، intentionality، and timing of use to theoretically root the subject of the study، which is one of the modern studies in Iraq and the Arab world. The survey approach، where the research was based on the theory of uses and gratifications that confer positivity and activity on the mass media audience.
The researchers designed
... Show MoreBackground: The best material for dental implants is polyetherketoneketone (PEKK). However, this substance is neither osteoinductive nor osteoconductive, preventing direct bone apposition. Modifying the PEKK with bioactive elements like strontium hydroxyapatite is one method to overcome this (Sr-HA). Due to the technique's capacity to provide better control over the coating's properties, RF magnetron sputtering has been found to be a particularly useful technique for deposition. Materials and methods : With specific sputtering conditions, the RF magnetron technique was employed to provide a homogeneous and thin coating on Polyetherketoneketone substrates.. the coatings were characterized by Contact angle, adhesion test, X-ray
... Show MoreThis study aimed at examining the role played by the media outlets during the coverage
of the presidential election campaigns 2020 of the United States of America.
The analytical study used through a partial inventory of the research community
for almost three months from the announcement of the candidates’ names by
the major parties on August 13 to November 6، which is the official election day in
the U.S. National Public Radio Station (NPR) to achieve the objectives of the study.
The study reached a number of conclusions related to the contents، methods and
sources of media coverage of the election campaigns of the 2020 U.S. at the mentioned
station، where the researcher proposed a number of recommendations
A thin film of AgInSe2 and Ag1-xCuxInSe2 as well as n-Ag1-xCuxInSe2 /p-Si heterojunction with different Cu ratios (0, 0.1, 0.2) has been successfully fabricated by thermal evaporation method as absorbent layer with thickness about 700 nm and ZnTe as window layer with thickness about 100 nm. We made a multi-layer of p-ZnTe/n-AgCuInSe2/p-Si structures, In the present work, the conversion efficiency (η) increased when added the Cu and when used p-ZnTe as a window layer (WL) the bandgap energy of the direct transition decreases from 1.75 eV (Cu=0.0) to 1.48 eV (Cu=0.2 nm) and the bandgap energy for ZnTe=2.35 eV. The measurements of the electrical properties for prepared films showed that the D.C electrical conductivity (σd.c) increase
... Show MoreIn this article, we developed a new loss function, as the simplification of linear exponential loss function (LINEX) by weighting LINEX function. We derive a scale parameter, reliability and the hazard functions in accordance with upper record values of the Lomax distribution (LD). To study a small sample behavior performance of the proposed loss function using a Monte Carlo simulation, we make a comparison among maximum likelihood estimator, Bayesian estimator by means of LINEX loss function and Bayesian estimator using square error loss (SE) function. The consequences have shown that a modified method is the finest for valuing a scale parameter, reliability and hazard functions.