Introduction: Methadone hydrochloride (MDN) is an effective pharmacological substitution treatment for opioids dependence, adopted in different countries as methadone maintenance treatment (MMT) programmes. However, MDN can exacerbate the addiction problem if it is abused and injected intravenously, and the frequent visits to the MMT centres can reduce patient compliance. The overall aim of this study is to develop a novel extended-release capsule of MDN using the sol-gel silica (SGS) technique that has the potential to counteract medication-tampering techniques and associated health risks and reduce the frequent visits to MMT centres. Methods: For MDN recrystallisation, a closed container method (CCM) and hot-stage method (HSM) were conducted, and MDN crystals were characterised using the polarised light microscope (PLM). MDN crystal thickness was determined by scanning electron microscopy (SEM) and confocal microscopy (CM) to establish a relationship between MDN crystals thickness and their birefringence colours using the Michel-Levy Birefringence Colour Chart. The experimental series was continued to produce novel silica-based MDN formulations A and B capsules by adding MDN powder at the end and beginning of the SGS process, respectively. The silica-based MDN formulations were characterised by Fourier transform infrared (FT-IR), SEM, differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), PLM and mean grey value (MGV) analyses. The in vitro release studies (n=3) for the silica-based MDN formulations and pure MDN capsules were conducted in a phosphate buffer solution (pH= 7.2) for 7 days. Stability studies were conducted for 1 month by keeping the silica-based MDN capsules under 25°C and 57% RH. Results: The optimal method to produce large numbers of MDN crystals was the CCM, and MDN crystals were characterised as diamond shaped with an intrinsic angle of 62o. The SEM surpassed the CM in measuring MDN crystal thickness, and Mann-Whitney U Test showed statistically significant differences between SEM and confocal thickness measurements (U= 1283, p < 0.05) as the SEM exhibited thinner diamond crystals (6.62 ± 2.9 µm) than the CM measurements (9.6 ± 4.6µm). According to the Michel-Levey birefringence colour chart (using the SEM mean thickness of MDN crystals and their retardation value of 428 nm), most of MDN crystals demonstrated a yellow colour. The FT-IR, SEM, DSC, MGV and PLM analyses of both silica-based MDN formulations revealed that MDN was successfully incorporated inside the silica network producing amorphous material (with no appearance of the melting peak of pure MDN at 233.4°C) with evidence of no physical or chemical interaction between sol-gel silica and MDN. However, the TGA analysis revealed a significantly greater amount of MDN was loaded inside the silica-based MDN formulation B compared to A (t = 2.80, p = 0.009, n=6), as 28.3 ± 0.6 mg of MDN was loaded in the former while 25.6 ± 0.7 mg in the latter. In addition, the silica-based MDN formulation B released 10% more MDN after 7 days than formulation A, and both formulations were stable when stored for 1 month under 57% RH and 25°C. Conclusion: The novel combined use of SEM and PLM techniques shows a potential for the identification of MDN in forensic science as it established a range of birefringence colours of MDN crystals. Moreover, the new silica-based MDN formulation B can help to deter MDN abuse and increase patient adherence to MMT due to its potential to sustain MDN release and reduce the frequent visits to MDN treatment centres.
The aims of the research is to know the role of Organisational learning in building talent management strategies in the Ministry of Science and Technology , where we see the challenges facing organizations today dictate now and in the future activation of scientific expertise to meet these challenges and the dissemination of these concepts within the priorities and data organizational culture of these organizations despite having a lot of the importance of organizational knowledge and learning applications .Despite learning and adopting some of the organizations have to enhance their competitiveness, we find a lot of organizations, including (The ministry researched) still do not realize the importance of the role of organization
... Show MoreIn this study, the energy charging mechanism is mathematically modeled to determine the impact of design modifications on the thermofluidic behavior of a phase change material (PCM) filled in a triplex tube containment geometry. The surface area of the middle tube, where the PCM is placed, is supported by single or multi-internal frustum tubes in vertical triplex tubes to increase the performance of the heating and cooling of the system. In addition to the ordinary straight triplex tubes, three more scenarios are considered: (1) changing the middle tube to the frustum tube, (2) changing the inner tube to the frustum tube, and (3) changing both the internal and central tubes to the frustum tubes. The impact of adopting the tube desig
... Show MoreResearch has included preparation of three of n Vthal acids Amec Bmentoj high of interaction vehicles Ortometta and bar aminophenol with phthalic anhydride was withdrawn water and ring closure of acids Alvthal AMEC prepared
In this research, new series of Furo-2-quinolone [FQ] compounds have been synthesized. These novel [FQ] compounds were prepared from coumarin derivatives (Furocoumarins: psoralen and isopsoralen).Identifications of these FQ compounds were performed by using infrared spectrum (I.R), Ultraviolet spectrum (U.V) and Nuclear Magnetic Resonance spectrum (H1-NMR) besides some physical data. The cytotoxic screening involves ;using HEP-2 cell line which gave differential responses against tested compounds : 4,6 Dimethyl furo[2, 3-g] coumarin (C1), 1-(2`, 4`, Dimethoxy benzylideneimino)-2,6-dimethyl Furo [2, 3-g] quinoline-2-one (C3) and the angular psoralen of the same derivative
... Show MoreExposing the dorsal superficial skin of rats to partial-depth burn leads to bacterial and microbes Invasion. Topical treatment is required in most superficial burn cases Moist exposed burn ointment (MEBO) protects wounds from infection and enhances healing without any harmful effects of purified chemicals is caused. The topical using of HA gel in rat models with full and partial thickness surgical wounds shows enhancement in wound repair. In this study, we compared the healing efficacy of topical use of hyaluronic acid gel products with MEBO as standard management in rats that were exposed to a partial-thickness burn. The experiment included twenty-four (24) adult albino rats of male sex with weight (150-220 gm) of 3 months’ age divided i
... Show More