Preferred Language
Articles
/
MxYcGocBVTCNdQwCUDfG
Integrating Petrophysical and Geomechanical Rock Properties for Determination of Fracability of the Iraqi Tight Oil Reservoir
...Show More Authors

Tight oil reservoirs have been a concerned of the oil industry due to their substantial influence on oil production. Due to their poor permeability, numerous problems are encountered while producing from tight reservoirs. Petrophysical and geomechanical rock properties are essential for understanding and assessing the fracability of reservoirs, especially tight reservoirs, to enhance permeability. In this study, Saadi B reservoir in Halfaya Iraqi oil field is considered as the main tight reservoir. Petrophysical and geomechanical properties have been estimated using full-set well logs for a vertical well that penetrates Saadi reservoir and validated with support of diagnostic fracture injection test data employing standard equations and correlations. Subsequently, breakdown pressures are computed, and two fracturing models have been developed. The petrophysical analysis infers that the reservoir has poor properties, while the findings of the geomechanical properties indicate that the reservoir is brittle with ductile rock strata. These ductile strata underlay and overlay more brittle formations than the reservoir. The results from diagnostic fracture injection test DFIT are quite consistent with well logs results. The breakdown pressure reflects that this reservoir could easily be fractured by inserting pressure equal to 6250 psi. However, the fracturing model design parameters manipulates the fracture height confinement within Saadi Formation and its propagation to Hartha and/or Tanuma Formations. Therefore, the employment of petrophysical and geomechanical properties of the rocks assists in understanding the fracability of the formation and demonstrating the orientation and the fracture propagation direction.

Scopus Crossref
View Publication
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Synthesis and Study the Structure, electrical and optical properties of Bi2-xCdxSr2Ca2Cu3O10+ δ thin film Superconductors
...Show More Authors

View Publication
Scopus (10)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Tue Jul 19 2022
Journal Name
Arabian Journal For Science And Engineering
Investigation of the Impacts of Nanomaterials on the Micromechanical Properties of Gypseous Soils
...Show More Authors

View Publication Preview PDF
Scopus (25)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Baghdad Science Journal
Effect of the Concentration of Copper on the Properties of Copper Sulfide Nanostructure
...Show More Authors

Nanoparticles of copper sulfide have been prepared by simple reaction between using copper nitrate with different concentrations ratio 0.1, 0.3, and 0.5 mM, thiourea by a simple chemical route. The prepared Nano powders have been deposited onto glass substrates by casting method at 60°C. The structure of the product Nano- films has been studied by x-ray diffraction, where the patterns showed that all the samples have a hexagonal structure of covellite copper sulfide with the average crystalline sizes 14.07- 16.51 nm. The morphology has been examined by atomic force microscopy, and field emission scan electron microscopy. The AFM images showed particles with almost spherical and rod shapes with average diameter sizes of 49.11- 90.64 nm.

... Show More
View Publication Preview PDF
Scopus (10)
Scopus Clarivate Crossref
Publication Date
Thu Dec 29 2016
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Solvent Extraction of Phenolic Compounds and Determination Total Phenolic Content from Teucrium Polium Plant
...Show More Authors

       A direct solvent extraction was used for the determination of phenolic compounds from Teucrium polium . Methanol, ethanol, iso-propanol, butanol and D.W  were used as an extractants and study  the affecting extraction factors including : the type and solvent concentration, temperature, extraction time and number of batch extraction, by  using Folin-ciocalteu method to determine the Total Phenolic Content (TPC) and measurement of the absorbance at λmax 765nm. The accuracy and precision of this method were determined by preparing laboratory samples of Gallic acid , the results showed relative errors ranging from ±0.5 – 1.49 % and the standard deviation equal to 1.2

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 14 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Diclofenac sodium Using 2,4-dinitrophenylhydrazine in Pure Form and Pharmaceutical Preparations
...Show More Authors

A simple and sensitive spectrophotometric method is described for the determination of diclofenac sodium (DCL), in pure form and pharmaceutical formulations. The method is based on the oxidation of 2,4-dinitrophenylhydrazine (2,4-DNPH) and coupling of the oxidized product with DCL in alkaline medium to give intensively colored chromogen which exhibits maximum absorption (λmax) at 600 nm, and the concentration of DCL was determined spectrophotometrically. The optimum reaction conditions and other analytical parameters were evaluated. In addition to classical univariate optimization, modified simplex method (MSM) has been applied in optimization of the variables affecting the color producing reaction. Beer’s law is obeyed in the

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 29 2016
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Ketotifen Fumarate in Pure and Pharmaceutical Preperations by Bromophenol Blue Reagent
...Show More Authors

         A spectrophotometric reliable, rapid and sensitive method has been developed and validated for  the determination Ketotifen fumarate  . A method was described for the determination of Ketotifen Fumarate  in pure form or pharmaceutical formulations, a colored ion-pair complex formation reaction among ketotifen fumarate and acid-dye bromophenol blue at pH 3.0 was used for the colorimetric determination of the drug. The complex formed was extracted into chloroform and the maximum absorbance of the solution was measured at 413 nm against blank. The calibration curve calculated obey Beer's law over the concentration range of 0.4-16 μg/ml and the regression equation was A=0.069

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 05 2017
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Bisacodyl in Pure and Pharmaceutical Preparation via Oxidative Coupling Organic Reaction
...Show More Authors

A simple, accurate and sensitive spectrophotometric way is used to determine Bisacodyl in pure and pharmaceutical preparations. The proposed method depends on using 2,4-Dinitrophenylhydrazine as chromogenic reagent . The method was based on the oxidative coupling reaction of Bisacodyl with 2,4-Dinitrophenylhydrazine with Sodium periodate in the presence of sodium hydroxide as alkaline media to form red water soluble dye product , that has a maximum absorption at ?max 522nm . Beer ,s law is obeyed in the concentration of (2.00–20.00) ?g.ml -1 .The molar absorptivity is (6505) L.mol-1.cm-1,a sandall sensitivity of(0.0555) ?g.cm-2), correlation coefficient of (0.9970) , Limitof detection (LOD) (0.0312 ?g.ml-1), limit of Quantitation (LOQ) (

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Crossref
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
Determination and evaluation of principal minerals in Negella sativa by atomic absorption technical methods
...Show More Authors

Determination and evaluation of principal minerals in Negella sativa by atomic absorption technical methods were showed, using wet ashing method. This work was done on Negella sativa because of wide using of this plant in many formulations ( in food or medicine ).two types of atomic absorptions were used : first, flame atomic absorption spectroscopy, for minerals of high concentrations such as, Na, Mg, K, Fe, Ca, Li, Ni, Zn, Mn, Cu. Second, flameless atomic absorption spectroscopy, for minerals of low concentrations such as, Al, Si, V, B, Pb, Co, Cd, Cr ,Si, Hg, Sn .The results showed the existence of many minerals in Negella sativa useful to human sanity with acceptable dietary allowance. On other side, the presence of harmful m

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Baghdad Science Journal
Simultaneous Ratio Derivative Spectrophotometric Determination of Paracetamol, Caffeine and Ibuprofen in Their Ternary Form
...Show More Authors

A new, accurate, precise and economic two spectrophotometric methods for determination of Paracetamol (Par), Ibuprofen (Ibu), and Caffeine (Caf) were suggested. Those methods were the first and second ratio derivative spectrum using a double devisor. Par, Ibu, and Caf showed many useful peaks for their quantified determination. The validity of all analysis modes for determination of the three compounds, peak to baseline, peak area and peak to peak were according to ICH. The linearity of two methods was between 5 µg/ml as a lower concentration and 50 µg/ml as the highest concentration for three compounds. Recovery percentage was around 100% and relative standard deviation was less than 2.6%. The methods were applied successfully in the

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Aug 30 2023
Journal Name
Iraqi Journal Of Science
Determination of Folic Acid in both Pure and Pharmaceutical Preparations via Oxidative Coupling Reaction
...Show More Authors

In this study, the development of an indirect spectrophotometric method for the determination of folic acid in pure and pharmaceutical preparations is described. The method is based on the oxidation of pyrocatechol with iron (III) in an acidic medium, followed by the reaction with folic acid (FA) to produce a stable, water-soluble orange compound with maximum absorption at 350 nm versus the blank reagent. The complex of charge transfer was studied under optimal conditions; the titration graph was linear over the range of 0.5-25 μg/mL with a relative error of 1.2-2.8 and a relative standard deviation of 2.43-1.45 depending on the concentration level.

View Publication Preview PDF
Scopus Crossref