Preferred Language
Articles
/
MhYcU4cBVTCNdQwCfUU6
The reliability of surgeons to avoid traumatic insertion of dental implants into high-risk regions: a panoramic radiograph study
...Show More Authors
Abstract<sec> <title>Background

The posterior regions of the jaws usually represent a significant risk for implant surgery. A non-valid assessment of the available bone height may lead to either perforation of the maxillary sinus floor or encroachment of the inferior alveolar nerve and consequently to implant failure. This study aimed to evaluate the reliability of surgeon’s decision in appraising the appropriate implant length, in respect to vital anatomical structures, using panoramic radiographs.

Methods

Only implants that are inserted in relation to the maxillary sinus (MS) or the mandibular canal (MC) were enrolled (first premolars [1P], second premolars [2P], first molars [1M], and second molars [2M]). All preoperative panoramic radiographs were evaluated under standard conditions. The postoperative estimation (under/over) was determined depending on the available bone height (ABH) measured from the apical end of the implant to the floor of the MS and the roof of the MC using cone beam computed tomography (CBCT). Any complication or side effect that associated with overestimated implants insertion was recorded.

Results

The study sample included 73 patients (predominantly females) who had consecutively received 148 implants, of which 68 were inserted in the posterior maxilla and 80 in the posterior mandible. Underestimation was recorded in 93.2% of the measurements. The remaining bone height after implants insertion was < 2 mm in the majority of underestimated cases (73.9%); they were significantly (P < 0.01) more than sites with remaining bone ≥ 2 mm (26.1%). In the posterior mandible, overestimation was significantly higher than posterior maxilla. Five cases with transient paresthesia were reported in the mandibular overestimated implants.

Conclusions

This study specified that surgeon’s choice of implants length, based on panoramic radiographs, was reliable regarding the incapability to insert implants with further length in the majority of underestimated cases, the low percent of overestimated measurements, and the minor associated complications.

Crossref
View Publication
Publication Date
Sun Sep 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Study in to the Dynamic Behavior of Packed Distillation Column
...Show More Authors

The study of the dynamic behavior of packed distillation column was studied by frequency response analysis using Matlab program. A packed distillation column (80 mm diameter) (2000 mm height) filled with glass packing (Raschig Rings 10mm), packing height (1500 mm) has been modified for separation of methanol-water mixture (60 vol%). The column dynamic behavior was studied experimentally under different step changes in, feed rate (±30%), reflux rate (±22%), and reboiler heat duty (±150%), the top and bottom concentration of methanol were measured. A frequency response analysis for the above step response was carried out using Bode diagram, the log modulus and the phase angle were  used to analyze the process model. A Matlab progra

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research &amp; Development
Post-Traumatic Stress Disorder among Women with Breast Cancer in Iraq: A Preliminary Report
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Periodicals Of Engineering And Natural Sciences
Constructing a new mixed probability distribution with fuzzy reliability estimation
...Show More Authors

This paper deals with constructing mixed probability distribution from mixing exponential

Scopus (5)
Scopus
Publication Date
Mon Feb 24 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Dental caries and salivary Interleukin-6 among preterm postpartum women in relation to baby birth weight (Comparative study)
...Show More Authors

Background: The physiologic, biochemical and anatomic changes that occur during pregnancy are extensive and may be systemic or local. However, most of these changes return to pre pregnancy status six weeks postpartum. The aim of the study was to investigate the effect of dental caries among preterm postpartum women and it's relation to baby birth weight and salivary interleukin-6 (IL-6). Materials and methods: 66 postpartum women were examined, 33 preterm postpartum women (study group) and 33 full term postpartum women (control group). Dental caries was recorded using, decayed, missing and filled surfaces index, also assess the decayed lesion by severity. Salivary samples were taken from all subjects to estimate salivary IL-6 levels. Babie

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 24 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Salivary cortisol among low birth weight 5 years old kindergarten children in relation to dental caries (comparative study)
...Show More Authors

Background: Birth weight is a powerful predictor of infant growth and survival. Evidence now shows that children born with low birth weight face an increased risk of chronic diseases and have many health problems including oral health. The aims of this study were to assess the salivary flow rate, viscosity, and salivary cortisol among low birth weight kindergarten children aged 5 years old in Hilla centre, in relation to dental caries and compares them with the normal birth weight children of the same age and gender. Materials and methods: The total sample involved 80 children (40 low birth weights and 40 normal birth weights) aged 5 years old. The diagnosis and recording of severity of dental caries was recorded through the application of

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
Studying Biomimetic Coated Niobium as an Alternative Dental Implant Material to Titanium (in vitro and in vivo study)
...Show More Authors

Commercially pure titanium (cpTi) is widely used as dental implant material although it was found that titanium exhibited high modulus of elasticity and the lower corrosion tendency in oral environment. Niobium(Nb) was chosen for this study as an alternative to cpTi implant material due to its bioinert behavior and good elastic modulus and moderate cost in addition to corrosion resistance. This study was done to evaluate the effect of biomimetic coating on the surface properties of the commercially pure titanium and niobium implants by in vitro and in vivo experiments. The in vitro study was involved etching the samples of each material in HCl then soaking in 10M NaOH aqueous solution. These samples were then immersed in a 5 times concent

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Jun 06 2020
Journal Name
Journal Of The College Of Education For Women
Conformity and nonconformity and their relation to the emotional balance of high school students
...Show More Authors

 Complex and complex psychological processes are complexand are the result of convergence, convergence and interaction between variables, including the subject of mediation or group or individual and psychological processes involved in the variance, including - personal knowledge and emotional tone (Osman, 1987, p. 8 ). An emotionally balanced individual has the ability to endure and delay meeting needs and has the ability to endure as much as possible. Of the emotional balance of the individual is characterized by emotional stability, show some signs of emotional agitation toward any kind of opposition, anger and realism in self-life and discipline (Swift, 1996, p. 44) Van, et al. , Indicates that people with low emotional balance,

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
A 980nm Diode Laser Clot Formation of the Rabbit’s Dental Sockets after Teeth Extraction
...Show More Authors

The aim of this research work is to evaluate the use of 980 nm diode laser in clotting the blood
in the bone socket after tooth extraction. The objective is to prevent possible clot dislodgement which is
a defect that may lead to possible infection. A number of rabbits were irradiated using 980nm CW mode
diode laser, 0.86W power output for 9s and 15s exposure time. The irradiated groups were studied
histopathologically in comparison with a control group. Results showed that laser photothermal
coagulation was of benefit in minimizing the possibility of the incidence of postoperative complications.
The formation of the clot reduces the possibility of bleeding and infection.

View Publication Preview PDF
Publication Date
Sun Jun 02 2019
Journal Name
Baghdad Science Journal
Estimating the Reliability Function of (2+1) Cascade Model
...Show More Authors

This paper discusses reliability R of the (2+1) Cascade model of inverse Weibull distribution. Reliability is to be found when strength-stress distributed is inverse Weibull random variables with unknown scale parameter and known shape parameter. Six estimation methods (Maximum likelihood, Moment, Least Square, Weighted Least Square, Regression and Percentile) are used to estimate reliability. There is a comparison between six different estimation methods by the simulation study by MATLAB 2016, using two statistical criteria Mean square error and Mean Absolute Percentage Error, where it is found that best estimator between the six estimators is Maximum likelihood estimation method.

View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Oct 23 2018
Journal Name
Journal Of Economics And Administrative Sciences
Comparison Bayes Estimators of Reliability in the Exponential Distribution
...Show More Authors

Abstract

           We produced a study in Estimation for Reliability of the Exponential distribution based on the Bayesian approach. These estimates are derived using Bayesian approaches. In the Bayesian approach, the parameter of the Exponential distribution is assumed to be random variable .we derived bayes estimators of reliability under four types when the prior distribution for the scale parameter of the Exponential distribution is: Inverse Chi-squar

... Show More
View Publication Preview PDF
Crossref