Preferred Language
Articles
/
MYYsqYYBIXToZYALaaOf
Extended Finite Element Analysis of Reinforced Concrete Beams Using Meso-Scale Modeling
...Show More Authors

Four simply supported reinforced concrete (RC) beams were test experimentaly and analyzed using the extended finite element method (XFEM). This method is used to treat the discontinuities resulting from the fracture process and crack propagation in that occur in concrete. The Meso-Scale Approach (MSA) used to model concrete as a heterogenous material consists of a three-phasic material (coarse aggregate, mortar, and air voids in the cement paste). The coarse aggregate that was used in the casting of these beams rounded and crashed aggregate shape with maximum size of 20 mm. The compressive strength used in these beams is equal to 17 MPa and 34 MPa, respectively. These RC beams are designed to fail due to flexure when subjected to load as a two-point loading. To model the coarse aggregate realistically, the aggregate must distributed randomly according to the gradient and amount actually used in the mix design. This property is not found in the ABAQUS program that resulted in the use of an alternate program to represent the aggregate randomly. Next, the random representation of the aggregate were transfered to the ABAQUS program by using commands and instructions that the program can understand, to draw as a sketch. The comparison between experimental and numerical results showed that the XFEM is a good method used to simulate the non-smooth behavior in RC beams such as discontinuitiy and singularity. While a mesoscale model can be simulated the non-homogeneity in the concrete.

Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Proceeding Of Second Thermal And Fluids Engineering Conference
Solidification Enhancement in Triplex-Tube Latent Thermal Energy Storage System Using a Combination of Nanoparticles and Fins
...Show More Authors

View Publication
Crossref (3)
Crossref
Publication Date
Wed Jul 01 2015
Journal Name
Magnetic Resonance Imaging
Alpha shape theory for 3D visualization and volumetric measurement of brain tumor progression using magnetic resonance images
...Show More Authors

Alpha shape theory for 3D visualization and volumetric measurement of brain tumor progression using magnetic resonance images

View Publication
Scopus (32)
Crossref (27)
Scopus Clarivate Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Malaysian Journal Of Science
DETERMINATION OF URANIUM CONCENTRATIONS IN RICE SAMPLES AVAILABLE IN THE IRAQI MARKET USING THE CR-39 DETECTOR
...Show More Authors

In this study, the results of the uranium concentrations and specific activity in 10 rice samples are described using a solid-state track detector (CR-39). Samples were collected from various local Iraqi markets with different origins (Iraq, India, America, and Thailand). Our findings found that the results of uranium concentration in all studied samples are ranging from (0.55 ± 0.28 to 1.74 ± 0.31) ppm with a weighted average of (1.24 ± 0.99) ppm. Also, results demonstrate that the specific activity values of the studied samples swing between values of (6.88 ± 3.52 and 21.49 ± 3.85) Bq/Kg. The obtained results of the studied rice samples are indicated that it is less than the acceptable limit of those studies established by ma

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
International Journal Of Thermal Sciences
Experimental and numerical investigations of heat transfer enhancement in shell and helically microtube heat exchanger using nanofluids
...Show More Authors

View Publication
Scopus (49)
Crossref (46)
Scopus Clarivate Crossref
Publication Date
Mon Aug 19 2024
Journal Name
Scientific Reports
An in-vitro evaluation of residual dentin retained after using novel enzymatic-based chemomechanical caries removal agents
...Show More Authors

To assess the biochemical, mechanical and structural characteristics of retained dentin after applying three novel bromelain‑contained chemomechanical caries removal (CMCR) formulations in comparison to the conventional excavation methods (hand and rotary) and a commercial papain‑contained gel (Brix 3000). Seventy‑two extracted permanent molars with natural occlusal carious lesions (score > 4 following the International Caries Detection and Assessment System (ICDAS‑II)) were randomly allocated into six groups (n = 12) according to the excavation methods: hand excavation, rotary excavation, Brix 3000, bromelain‑contained gel (F1), bromelain‑chloramine‑T (F2), and bromelain chlorhexidine gel (F3). The superficial and deepe

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Engineering
Water Quality of Tigris River in Mosul and Al-Amarah Cities by using CCME Water Quality Index
...Show More Authors

This study aims to assess the water quality index (WQI) according to the Canadian Council of Ministers of the Environment's Water Quality Index method (CCME WQI). Four locations (measurement stations) are selected along the Tigris River, in Iraq.  Two of them are located in the north near Mosul City, (Mosul Dam and Mosul city), and the other two are located in the south near Al-Amarah city, (Ali Garbi and Al-Amarah). The water data collected is for the period 2011 to 2013, including eleven water quality parameters. These are magnesium (Mg+2), calcium (Ca2+), potassium (K+), sodium (Na+), sulfate (SO42-), chloride (Cl-), nitrate (NO3<

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Simultaneous Determination of Piroxicam and Codeine Phosphate Hemihydrate in a Pharmaceutical Dosage Form Using Validated HPLC Method
...Show More Authors

An easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Engineering
Separation of Lead (Pb2+) and Cadmium (Cd2+) from Single and Binary Salt Aqueous Solutions Using Nanofiltration Membranes
...Show More Authors

The present work reports on the performance of three types of nanofiltration membranes in the removal of highly polluting and toxic lead (Pb2+) and cadmium (Cd2+) from single and binary salt aqueous solutions simulating real wastewaters. The effect of the operating variables (pH (5.5-6.5), types of NF membrane and initial ions concentration (10-250 ppm)) on the separation process and water flux was investigated. It was observed that the rejection efficiency increased with increasing pH of solution and decreasing the initial metal ions concentrations. While the flux decreased with increasing pH of solution and increasing initial metal ions concentrations. The maximum rejection of lead and cadmium ion

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 24 2025
Journal Name
Journal Of Physical Education
The Effect of Compound Exercises Using Added Relative Weights On Some Physical Abilities In Young Soccer Players
...Show More Authors

View Publication
Publication Date
Mon Dec 30 2024
Journal Name
Wasit Journal For Pure Sciences
A New Class of Higher Derivatives for Harmonic Univalent Functions Established using a Generalized Fractional Integral Operator
...Show More Authors

A new class of higher derivatives  for harmonic univalent functions defined by a generalized fractional integral operator inside an open unit disk E is the aim of this paper.

View Publication
Crossref