Preferred Language
Articles
/
MRdaWJMBVTCNdQwCStGN
Study of the Effect of Diabetes Mellitus I on Bone Mineral Density of Upper and Lower Limbs by Dual-Energy X-Ray Absorptiometry

Background: Bone mineral density (BMD) has been assessed using Dual-Energy X-ray absorptiometry (DEXA). This procedure is considered to be of vital importance in assessing the general condition of individuals concerning their skeletal mineralization. BMD is measured according to the results of the DEXA examination of the vertebral column and pelvis. Although diabetes mellitus (D.M.)is known to affect BMD, the information regarding this relationship is not currently particularly clear. Objective: This study concentrates on the point that the assessment of BMD for the vertebral column is insuffi-cient to give a realistic and correct picture of the mineralization of the remaining part of the skeleton. Besides, this study elicited a generalized view of the mineralization of the different body parts between genders and between the left and right sides of the body. The effect of DM I on BMD was evaluated well in this research. Method: This study involved 165 patients complaining of bone pain (85 male and 80 female), about half of whom suffered from diabetes, involving both genders. Further, 90 healthy volunteers had been studied and were considered to constitute the control group. All individuals (255) in this study were exposed to the study of their BMD via DEXA for all parts of the body. Results: The DEXA exam revealed highly statistically significant differences between the sides of the body in the same subject. In addition, there were significant differences in BMD between females and males and highly statistically significant differences between the control and patient groups with DM I. Finally, this study offered strong evidence that the BMD of the vertebral column and pelvis did not give an accurate picture of mineralization in the different parts of the body for a given subject. In conclusion, the DEXA scan for the whole body and each part separately shows promising results as alternative parameters of the DEXA scan for the spine or hip only for accurate diagnosis. Our results indicate that the BMD of the left and right sides for women was less than for men in all cases (average, osteoporosis, and DMI with osteoporosis) for the same sides and between their upper and lower limbs. Patients with DMI revealed significant reductions in BMD in comparison with other subjects who were not diabetic, even if they had osteoporosis. Keywords: DEXA scan, Osteoporosis, DMI, BMD

Scopus Crossref
View Publication
Publication Date
Wed Jun 15 2022
Journal Name
Malaysian Journal Of Science
STUDY THE RELATIONSHIP BETWEEN BREMSSTRAHLUNG DOSE RATE AND THE ENERGY OF BETA RAY FOR DIFFERENT TYPES OF SHIELD

The dose rate for bremsstrahlung radiation from beta particles with energy (1.710) MeV and (2.28) MeV which comes from (32P and 90Y) beta source respectively have been calculated through six materials (polyethylene, wood, aluminum, iron, tungsten and lead) for first shielding material with thickness (x=1) mm which are putting between beta sources and second shield (polyethylene, aluminum and lead) with thickness (1, 2 &4) mm have been calculated. The distance between beta source and second shield is constant (D=1) cm. This dose rate was found by program called Rad Pro Calculator (version 3.26). The results of dose rate of beta particles were plotted as a function to the atomic number (Z) for first shield materials for each

... Show More
Preview PDF
Publication Date
Wed Jun 15 2022
Journal Name
Malaysian Journal Of Science
STUDY THE RELATIONSHIP BETWEEN BREMSSTRAHLUNG DOSE RATE AND THE ENERGY OF BETA RAY FOR DIFFERENT TYPES OF SHIELD

The dose rate for bremsstrahlung radiation from beta particles with energy (1.710) MeV and (2.28) MeV which comes from (32P and 90Y) beta source respectively have been calculated through six materials (polyethylene, wood, aluminum, iron, tungsten and lead) for first shielding material with thickness (x=1) mm which are putting between beta sources and second shield (polyethylene, aluminum and lead) with thickness (1, 2 &4) mm have been calculated. The distance between beta source and second shield is constant (D=1) cm. This dose rate was found by program called Rad Pro Calculator (version 3.26). The results of dose rate of beta particles were plotted as a function to the atomic number (Z) for first shield materials for each

... Show More
Scopus (1)
Scopus Crossref
View Publication
Publication Date
Thu Jan 15 2015
Journal Name
مجلة كلية التربية-المؤتمر العلمي التخصصي لكلية التربية
Investigation the Effect of Irradiation by Gamma-Ray on the Structural and Optical Properties of (CIGS) Films

Publication Date
Sun Mar 26 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Gestational Diabetes Mellitus and Hormonal Alteration

Gestational Diabetes Mellitus is known as carbohydrate intolerance first detected during pregnancy. Pregnancy is periods of intense hormonal changes. The aim of the present study was to investigate a possible relation between the changes in serum hormones such as Luteinizing hormone (LH) , follicle stimulating hormone(FSH), Progesterone, and Prolactin with gestational diabetes mellitus. Thirty patients with gestational diabetes mellitus aged (22 -40) year attending the national center for treatment and research of diabetes/ AL-Mustansiriya University in Baghdad and 29 controls aged (20-39) year were participated. Hormonal tests including, FSH, LH, Progesterone, and Prolactin were detected by using Enzyme Linked Fluorescent Assay (ELFA) k

... Show More
Crossref
View Publication Preview PDF
Publication Date
Wed Apr 01 2009
Journal Name
Journal Of The Faculty Of Medicine Baghdad
The Value of the chest X-Ray for diagnosing left ventricular Dysfunction

Background: The use of the chest x-ray measurements which includes the cardiothoracic ratio(C-T) and frontal area (FA) of the heart by the CXR are useful measures for primary assessment of the cardiac dysfunction.
Patients and Methods: A Prospective study was done from the 1st of January 2005 to the 1st of October in the same year on a 120 consecutive patients who have been admitted for coronary and L.V angiogram at IBN-AL-BITAR hospital. The C-T ratio and the frontal area were measured.
Results: The study comprised 120 subjects who were admitted for coronary and L.V angiogram for diagnostic reasons. 89subjects (74.2%) are male and 31subjects (25.8%) are female .17(14%) subjects have left ventricular d

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Mon Oct 30 2017
Journal Name
International Journal Of Science And Research
Measurements of X-Ray Dose Delivered at Different Depths Applied on Water Phantom

Background: Radiotherapy, is therapy using ionizing radiation in order to deliver an optimal dose of either particulate or electromagnetic radiation to a particular area of the body with minimal damage to normal tissues. The source of radiation may be outside the body of the patient (external beam irradiation) or it may be an isotope that has been implanted or instilled into abnormal tissue or a body cavity. Called also radiotherapy. The aim of work studies the relationship between the depth dose and the high photon xray energies (6MeV and 10MeV). Patients and methods: in our work, we studied the dose distribution in water phantom given at different depths (zero-18) cm deep at1cm intervals treated with different field size (5×5-,10×1

... Show More
Publication Date
Thu Dec 31 2020
Journal Name
Neuroquantology
Assessment of Some Enhancement Methods of Renal X-ray Image

The study focuses on assessment of the quality of some image enhancement methods which were implemented on renal X-ray images. The enhancement methods included Imadjust, Histogram Equalization (HE) and Contrast Limited Adaptive Histogram Equalization (CLAHE). The images qualities were calculated to compare input images with output images from these three enhancement techniques. An eight renal x-ray images are collected to perform these methods. Generally, the x-ray images are lack of contrast and low in radiation dosage. This lack of image quality can be amended by enhancement process. Three quality image factors were done to assess the resulted images involved (Naturalness Image Quality Evaluator (NIQE), Perception based Image Qual

... Show More
Scopus Crossref
View Publication
Publication Date
Fri Jun 24 2022
Journal Name
Iraqi Journal Of Science
Determination the density of cometary nucleus material using gamma ray attenuation

In this work, the technique of attenuation of gamma ray to calculate the density of comet nucleus materials (C/2009 P1 (GARRADD) at different range of energy (0.2- 0.9 MeV). also, the single scattering model for gamma rays has been assumed that photons reaching the detector with scattered only once in the material. The program has been designed and written in FORTRAN language (77 – 90) to calculate the density for molecules using Monte Carlo method was used to simulate the scattering and absorption of photons in semi- infinite material. Gamma ray interacts with the matter by three mainly interactions: Photoelectric effect, Compton scattering and Pair production (electron and positron). On the 137Cs source energy (662 keV), Compton scat

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 11 2022
Journal Name
3rd International Scientific Conference Of Alkafeel University (iscku 2021)
Elimination of the broadening in X-ray diffraction lines profile for nanoparticles by using the analysis of diffraction lines method

In this research, the results of the Integral breadth method were used to analyze the X-ray lines to determine the crystallite size and lattice strain of the zirconium oxide nanoparticles and the value of the crystal size was equal to (8.2nm) and the lattice strain (0.001955), and then the results were compared with three other methods, which are the Scherer and Scherer dynamical diffraction theory and two formulas of the Scherer and Wilson method.the results were as followsScherer crystallite size(7.4nm)and lattice strain(0.011968),Schererdynamic method crystallite size(7.5 nm),Scherrer and Wilson methodcrystallite size( 8.5nm) and lattice strain( 0.001919).And using another formula for Schearer and Wilson methodwe obtain the size of the c

... Show More
Scopus (3)
Crossref (2)
Scopus Crossref
View Publication
Publication Date
Sun Dec 01 2013
Journal Name
Baghdad Science Journal
Assessment of Inflammasome Activity in Type 2 Diabetes Mellitus and Simple Obesity: Comparative Study

Inflammasome is a multiprotein oligomer complex which is the precursor procaspase-1 and is a component of the innate immune system so that this study aimed to determine the serum levels of interleukin-1? and 18 in patients with T2D and simple obesity in an attempt to clarify the role of inflammasome in these disorders.Twenty five known cases of T2D, twenty four patients with simple obesity and twenty healthy subjects were randomly recruited from AL-Kindy Teaching Hospital in Baghdad to enroll in this study. All the data about the demographic characteristics and anthropometric measurements were determined in all patients, also the C-reactive protein and serum interleukin (IL)-1? and IL-18 levels were obtained from each patient. The results s

... Show More
Crossref
View Publication Preview PDF