Preferred Language
Articles
/
MBcmoZIBVTCNdQwCZLs2
FORMULATION AND IN VITRO EVALUATION OF BROMOCRIPTINE MESYLATE AS FAST DISSOLVING ORAL FILM
...Show More Authors

Objective: The aim of this study was to formulate and in vitro evaluate fast dissolving oral film of practically insoluble bromocriptine mesylate to enhance its solubility and to improve its oral bioavailability by avoiding first pass effect as well as to produce an immediate release action of the drug from the film for an efficient management of diabetes mellitus type II in addition to an improvement of the patient compliance to this patient- friendly dosage form. Methods: The films were prepared by the solvent casting method using hydroxypropyl methylcellulose of grades (E3, E5, E15), polyvinyl alcohol (PVA), pectin and gelatin as film-forming polymers in addition to polyethene glycol 400 (PEG400), propylene glycol (PG) and glycerin were used as a plasticizer. Poloxamer 407 was used as a surfactant, sodium saccharin as a sweetening agent, citric acid as a saliva stimulating agent, vanilla as a flavouring agent and crospovidone as a super disintegrant. The prepared films then tested for physical characterization, thickness, weight uniformity, mechanical characteristics (folding endurance, tensile strength, percent elongation and Young's modulus), surface pH, in vitro disintegration time, drug content and an in vitro drug release. Results: Films were found to be satisfactory when evaluated for physical characterization, thickness, weight uniformity, mechanical tests, in vitro disintegration time, folding endurance, drug content and an in vitro drug release. The surface pH of all the films was found to be neutral or minor change. Films in vitro drug release studies were also done using USP dissolution apparatus type II (paddle type). The in vitro drug release profile in the optimized formulation F14 was gave 86.8 % of drug released at 2 min. The optimized formulation F14 was also showed satisfactory pH (6.2±0.2), drug content (99.2±0.5%), the disintegration time of 9.2±0.1 seconds and the time needed for 80% of medication to be released (T80 %) was 1.35 minute. Conclusion: The bromocriptine mesylate fast dissolving oral film was formulated. The given film disintegrates within nine seconds which release the drug rapidly and gives an action.

Scopus
Publication Date
Sat Jun 03 2023
Journal Name
Iraqi Journal Of Science
Fast encoding algorithm based on Weber's law and Triangular Inequality Theorem
...Show More Authors

In the present work, an image compression method have been modified by combining The Absolute Moment Block Truncation Coding algorithm (AMBTC) with a VQ-based image coding. At the beginning, the AMBTC algorithm based on Weber's law condition have been used to distinguish low and high detail blocks in the original image. The coder will transmit only mean of low detailed block (i.e. uniform blocks like background) on the channel instate of transmit the two reconstruction mean values and bit map for this block. While the high detail block is coded by the proposed fast encoding algorithm for vector quantized method based on the Triangular Inequality Theorem (TIE), then the coder will transmit the two reconstruction mean values (i.e. H&L)

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 15 2022
Journal Name
Al-academy
Modern sound systems and their work in contemporary feature film
...Show More Authors

Perhaps going to watch movies in cinemas today has become different from what it was before. The cinematic film, the clarity of the image and the luster of its colors pulled the rug out from under the most important change that occurred in the structure of the contemporary cinematography, which is the sound. The surround sound environment that immerses viewers in the realism of sound that reaches them from all directions, and for this the researcher found it necessary to shed light on this topic because of its importance, so the research problem was represented in the following question: (How are modern sound systems used in the structure of contemporary feature films?) The theoretical framework included two topics: the first: the dialec

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 15 2019
Journal Name
Al-academy
Women and Ideology in the Feature Film: بان جبار خلف
...Show More Authors

The topic of research (women and ideology in the feature film) is a series of researches addressed by the researcher on the subject of women in the feature film through studying the ideology as a thought and political system not only limited to the world of men, but women had a significant contribution in this area.  The research identified the problem and its need as well as the objectives of the research and clarified its limits and importance. The research also identified the theoretical framework, which included the following axes: personality and ideology, film and ideology, then women and ideology in the film.

After the completion of the theoretical framework, the research concluded a set of indicators of the theoretic

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 29 2024
Journal Name
Journal Of Baghdad College Of Dentistry
An Evaluation of Corrosion Pits in Esthetic Coated Stainless Steel Orthodontic Archwires in Dry and Wet Environment at Different Intervals (An In Vitro Study)
...Show More Authors

Background: The demand for esthetic orthodontic appliances is increasing; so the esthetic orthodontic archwires were introduced. Among them, Teflon and Epoxy coated stainless steel archwires. The amount of force available from the archwire depends on the structural properties and susceptibility to corrosion. All metallic alloys are changed during immersion in artificial saliva, chlorhexidine mouthwash andtoothpaste, but their behaviors differ from one type to another. They corrode at different rates, which lead to decrease the amount of force applied to the teeth. This in vitro study was designed to evaluate the corrosion pits in stainless steel archwires coated with Teflon and with Epoxy in dry and after immersion in artificial saliva, chl

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jul 01 2019
Journal Name
2019 International Joint Conference On Neural Networks (ijcnn)
A Fast Feature Extraction Algorithm for Image and Video Processing
...Show More Authors

View Publication
Scopus (37)
Crossref (35)
Scopus Clarivate Crossref
Publication Date
Thu Aug 18 2022
Journal Name
Dental Hypotheses
Microleakage Evaluation of Glass Hybrid Restoration Following Usage of Papain-Based Gel and Ceramic Bur for Caries Removal: An in Vitro Study
...Show More Authors

Scopus Crossref
Publication Date
Sun Dec 29 2024
Journal Name
Journal Of Baghdad College Of Dentistry
The validity of salivary microRNAs (hsa-miR-200a, hsa-miR-125a and hsa- miR-93) as oral squamous cell carcinoma biomarker
...Show More Authors

Background: Oral squamous cell carcinoma represents the vast majority of oral cancer it is a common malignant tumor with an increasing incidence. Around the world, the 5 year mortality rate of oral cancer is about 50%. Thus novel biomarkers for early detection oral squamous cell carcinoma are needed. The level of three salivary microRNAs namely hsa-miR-200a, hsa-miR-125a and hsa- miR-93 were measured in saliva of patients with oral squamous cell carcinoma and compared their levels in saliva of healthy control subjects to determine their potential as oral cancer biomarker. Materials and methods: The level of these three microRNAs was measured by using revers transcription, preamplification and quantitative PCR. Results: Only miR-200a presen

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Baghdad College Of Dentistry
A Comparative Evaluation of Apical Seal Associated with Ultrasonic Retrograde Cavities Filled with Bioactive Material ( in Vitro Study )
...Show More Authors

Background: The aim of this study was to evaluate and compare the apical microleakage around retrograde cavities prepared with ultrasonic technique and filled with (Biodentineâ„¢) Materials and methods: 40 extracted single rooted human permanent maxillary teeth with mature apices were selected. The roots were prepared chemo-mechanically using k-files with crown-down technique and then obturated with lateral condensation gutta-percha technique. Teeth were divided into four main groups according to the cavity preparation method either manual or ultrasonic technique: Group A (n=10): A class I retrograde cavity at root end was prepared with traditional handpeice equipped and placement of Biodentine with manual condensation. Group B (n=10):

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
A Comparative Evaluation of Apical Seal Associated with Ultrasonic Retrograde Cavities Filled with Bioactive Material (In Vitro Study)
...Show More Authors

Background: The aim of this study was to evaluate and compare the apical microleakage around retrograde cavities prepared with ultrasonic technique and filled with (Biodentineâ„¢) Materials and methods: 40 extracted single rooted human permanent maxillary teeth with mature apices were selected. The roots were prepared chemo-mechanically using k-files with crown-down technique and then obturated with lateral condensation gutta-percha technique. Teeth were divided into four main groups according to the cavity preparation method either manual or ultrasonic technique: Group A (n=10): A class I retrograde cavity at root end was prepared with traditional handpeice equipped and placement of Biodentine with manual condensation. Group B (n=10):

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jun 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the effect of preheating on micro leakage of Class II composites Restoration (A comparative in vitro study)
...Show More Authors

Background: The aim of this in vitro study was to evaluate and compare the effect of preheating microleakage among three different filler size composites which include Filtektm Z250 micro hybrid, Z250xt Nano hybrid and nanocomposite Z350xt.  in Class II cavity preparation .

Materials and methods: sixty maxillary first premolars were prepared with class II cavities. Samples were divided into three groups according to material used    group A (FiltekZ250 micro hybrid). Group B(Z250xt Nano hybrid). Group C (nanocomposite Z350xt)and each group divided into two subgroups of ten teeth according to temperature of  composite:

... Show More
View Publication
Crossref