Very Low Illumination Image Enhancement via Lightness Mapping

Scopus Crossref
View Publication
Publication Date
Wed Dec 20 2023
Journal Name
Migration Letters
Preview PDF
Publication Date
Fri Nov 20 2015
Journal Name
Iraqi Journal Of Science
New Approach for Determination of Oxonium Ion in Inorganic Acids by Quenched Fluorescence of Analytically Interested Species via the Liberated Bromine Using Continuous Flow Injection Laser Diode Fluorimeter Analyser

A new method is characterized by simplicity, accuracy and speed for determination of Oxonuim ion in ionisable inorganic acid such as hydrochloric (0.1 - 10) ,Sulphuric ( 0.1 - 6 ),nitric ( 0.1 - 10 ), perchloric ( 0.1 - 7 ), acetic (0.1 - 100 ) and phosphoric ( 0.1 - 30 ) ( mMol.L-1 )acids. By continuous flow injection analysis. The proposed method was based on generation of bromine from the Bro-3-Br-- H3O+. Bromine reacts with fluorescein to quenches the fluorescence . A sample volume no.1 (31μl) and no.2 (35μl) were used with flow rate of 0.95 mL.min-1 using H2O line no.1as carrier stream and 1.3 mL.min-1 using fluorescein sodium salt line no.2. Linear regression of the concentration ( mMol.L-1 ) Vs quenched fluorescence gives a correla

... Show More
View Publication
Publication Date
Wed Nov 14 2018
Journal Name
Journal Of Engineering And Applied Sciences
Publication Date
Sun Jul 02 2023
Journal Name
Iraqi Journal Of Science
Chemiluminometric- CFIA for the Determination of Cobalt (ll) Ion in Commercial Cobalt-Molybdenum Catalyst (K F124-3E) Used in Desulphurization Processes of Petroleum Products via Multi Gel Beads Reactor.

Co(II) ion was determined by a new, accurate, sensitive and rapid method via a
continuous flow injection analysis (CFIA) with a chemiluminescence reaction based on
the oxidation of Luminol which is loaded on poly acrylic acid gel beads by hydrogen
peroxide in presence of Cobalt (II) ion as a chemiluminescence catalyst. Chemical and
physical parameters were investigated to obtain the best conditions. Linear dynamic
range of Cobalt (II) ion was from 0.1-20.0 μg.ml-1 with a correlation coefficient r =
0.9758, limit of detection (L.O.D) 0.2 ng/sample from the step wise dilution of lowest
concentration in the calibration graph with the percentage relative standard deviation for
3 μg.ml-1 Co(ll) solution is 0.8537% (n

... Show More
View Publication Preview PDF
Publication Date
Wed Nov 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Building marketing culture and reflection on the mental image Search for a pilot sample of managers in the General Company for Vegetable Oil Industry

          The subject of marketing culture and mental image is one of the important topics in the field of management. There is no study that combines these two variables. The research is important because of the increasing importance of the subject. The future direction of the company in question will support the company's economic and marketing responsibilities. And reflect the company's mental image, as a culture that contributes to changing the reality of the organization investigated by polling the views of a sample of managers in the General Company for Vegetable Oil Industry, which (30) out of the (65) individual, and There are two hypotheses of research: There is a significant

... Show More
Crossref
View Publication Preview PDF
Publication Date
Mon Dec 31 2018
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
ELEMENTS OF MARKETING MIX AND THEIR ROLE IN CONSUMER PERCEPTION OF BRAND IMAGE: A SURVEY OF SAMPLE OPINIONS FROM CONSUMERS OF ENIEM BRAND IN THE ALGERIAN MARKET.: ELEMENTS OF MARKETING MIX AND THEIR ROLE IN CONSUMER PERCEPTION OF BRAND IMAGE: A SURVEY OF SAMPLE OPINIONS FROM CONSUMERS OF ENIEM BRAND IN THE ALGERIAN MARKET.

The current research aimed to analyze the importance, correlation and the effect of independent variables represented by marketing variables on the dependent variable represented by local brand, through taking ENIEM as a model for this study, which represents a sensitive sector for the Algerian consumer. The results of the study evinced that the Algerian consumer has a positive image toward the brand ENIEM given marketing variables which has acquired considerable importance to this consumer. Also, the results of this study showed a statistically significant correlation between marketing variables and good perception toward the brand ENIEM, at the same time, the existence of a statistically significant effect for each of these variables o

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 02 2023
Journal Name
Iraqi Journal Of Science
New Approach for the On-Line Spectrophotometric Determination of Vanadium (V) In Different River Water via the Use of a Homemade Ayah 6SX1-T-2D Solar-Continuous Flow Injection Analyser

A new simple sensitive and selective spectrophotometric method has been
developed for the analysis of vanadium(V) in three randomly chosen samples from
river water at different locations by continuous flow injection analysis. The method
based on the oxidation of pyrogallol by vanadium(V) in acidic solution to form color
species and the same species was determined using homemade Ayah 6SX1-T-2D
solar cell analyser . Chemical and physical parameters were investigated using the
high intensity of snow white light emitted diode as a source. The linear dynamic
range for the instrument response versus vanadium(V) concentration was 1-200
mg.L-1 with correlation coefficient r = 0.9920. The limit of detection (S/N=3) was 70<

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 07 2008
Journal Name
Baghdad Science Journal
New Method for Determination of Molybdenum(VI) through Flow Injection Analysis Via the Consumption of Liberated Oxygen from Reaction System Ammonia-Hydrogen peroxide-Molybdenum(VI) in the Presence of Pyrogallol

This piece of research work aims to study one of the most difficult reaction and determination due to continuous and rapid variation of reaction products and the reactants. As molybdenum (VI) aid in the decomposition of hydrogen peroxide in alkaline medium of ammomia, thus means a continuous liberation of oxygen which cuases and in a continuous manner a distraction in the measurement process. On this basis pyrogallol was used to absorbe all liberated oxygen and the result is an a clean undisturbed signals. Molybdenum (VI) was determined in the range of 4-100 ?g.ml-1 with percentage linearity of 99.8% or (4-300 ?g.ml-1 with 94.4%) while L.O.D. was 3.5 ?g.ml-1. Interferring ions (cations and anions) were studied and their main effect was red

... Show More
Crossref
View Publication Preview PDF
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
New Approach for an On-Line Turbidimetric Determination of Cadmium (II) in Different River Water Via the Use of A homemade Ayah 6SX1-T-2D Solar-Continuous Flow Injection Analyser

A newly developed analytical method characterized by its speed and sensitivity for
the determination of cadmium (II) in aqueous solution in three randomly chosen
samples from river water at different locations via turbidimetric measurement by
Ayah 6SX1-T-2D Solar - CFI analyser. The method is based on the formation of
yellowish white precipitate for the complex Cd3[Fe(CN)6]2 by direct reaction of the
cadmium (II) with potassium hexacyano ferrate (III) in aqueous medium. Turbidity
was measured via the reflection of incident light that collides on the surfaces
precipitated particles at 0-180o. Chemical and physical parameters were investigated.
Linear dynamic of cadmium (II) is ranged from 0.05-12 mmol.L-1, with cor

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
New Approach for the On-Line Spectrophotometric Determination of Vanadium (V) In Different River Water via the Use of a Homemade Ayah 6SX1-T-2D Solar-Continuous Flow Injection Analyser

A new simple sensitive and selective spectrophotometric method has been developed for the analysis of vanadium(V) in three randomly chosen samples from river water at different locations by continuous flow injection analysis. The method based on the oxidation of pyrogallol by vanadium(V) in acidic solution to form color species and the same species was determined using homemade Ayah 6SX1-T-2D solar cell analyser . Chemical and physical parameters were investigated using the high intensity of snow white light emitted diode as a source. The linear dynamic range for the instrument response versus vanadium(V) concentration was 1-200 mg.L-1 with correlation coefficient r = 0.9920. The limit of detection (S/N=3) was 70 ng/ sample from the step

... Show More
View Publication Preview PDF