In modern technology, the ownership of electronic data is the key to securing their privacy and identity from any trace or interference. Therefore, a new identity management system called Digital Identity Management, implemented throughout recent years, acts as a holder of the identity data to maintain the holder’s privacy and prevent identity theft. Therefore, an overwhelming number of users have two major problems, users who own data and third-party applications will handle it, and users who have no ownership of their data. Maintaining these identities will be a challenge these days. This paper proposes a system that solves the problem using blockchain technology for Digital Identity Management systems. Blockchain is a powerful technique to build a digital identity in chain matters that enables a secure environment. The idea of Blockchain is to distribute the data across multiple devices in a cryptographic way, which will reduce the ability to an impossible level. Therefore, in this paper a proposed Digital Identity based on Blockchain (ERC 725, and ERC 735) with MD6 as a hashing algorithm will be implemented in a Secure smart contract can prevent function calls from being carried out until the sender has received confirmation from a reliable issuer; for example, we might include a feature that restricts smart contract interactions to legitimate users only. Many additional use cases are possible with ERC-725, including multi-sig execution approvals and contract call verification in place of key validation.
LED is an ultra-lightweight block cipher that is mainly used in devices with limited resources. Currently, the software and hardware structure of this cipher utilize a complex logic operation to generate a sequence of random numbers called round constant and this causes the algorithm to slow down and record low throughput. To improve the speed and throughput of the original algorithm, the Fast Lightweight Encryption Device (FLED) has been proposed in this paper. The key size of the currently existing LED algorithm is in 64-bit & 128-bit but this article focused mainly on the 64-bit key (block size=64-bit). In the proposed FLED design, complex operations have been replaced by LFSR left feedback technology to make the algorithm perform more e
... Show MoreThis study designed to prepare ultrafine apixaban (APX) o/w nanoemulsion (NE) based gel with droplet size below 50 nm as a good method for transdermal APX delivery without using permeation enhancer, alternatively, the formulation components itself act as permeation enhancer. APX, a potent oral anticoagulant drug that selectively and directly inhibit coagulation factor Xa, was selected as a good candidate for transdermal delivery as it displays poor water solubility (0.028 mg/mL) and low bioavailability (50%). APX-NE gel was prepared using triacetin, triton-x-100 and carbitol as oil phase, surfactant and cosurfactant respectively, while Carbopol 940 used as a gelling agent. Ex vivo permeation of APX-NE gel through human stratum c
... Show MoreWith the increasing integration of computers and smartphones into our daily lives, in addition to the numerous benefits it offers over traditional paper-based methods of conducting affairs, it has become necessary to incorporate one of the most essential facilities into this integration; namely: colleges. The traditional approach for conducting affairs in colleges is mostly paper-based, which only increases time and workload and is relatively decentralized. This project provides educational and management services for the university environment, targeting the staff, the student body, and the lecturers, on two of the most used platforms: smartphones and reliable web applications by clo
I
In this study, optical fibers were designed and implemented as a chemical sensor based on surface plasmon resonance (SPR) to estimate the age of the oil used in electrical transformers. The study depends on the refractive indices of the oil. The sensor was created by embedding the center portion of the optical fiber in a resin block, followed by polishing, and tapering to create the optical fiber sensor. The tapering time was 50 min. The multi-mode optical fiber was coated with 60 nm thickness gold metal. The deposition length was 4 cm. The sensor's resonance wavelength was 415 nm. The primary sensor parameters were calculated, including sensitivity (6.25), signal-to-noise ratio (2.38), figure of merit (4.88), and accuracy (3.2)
... Show MoreThe goal of this research to identify a set of criteria that can be measured on the basis of which the effectiveness of the application of the Balanced Scorecard in the Jordanian Public Institutions in order to identify the basic requirements to ensure the application of balanced performance measures. The study population consisted of the staff of the Public Institution for Social Security - Irbid of directors of departments and heads of departments and administrative staff, was the use of a random sample of (50) an employee and the employee. The questionnaire was used as a tool to collect data, and as a result of subjecting these standards for the field test and the use of statistical analysis tools to the results of the study c
... Show MoreThis research aims to clarify the role of Information Technology Competency (ITC) with dimensions' (IT Usage, IT Knowledge, and IT Operations) as an independent variable in the activation of Human Resources Management Practices (HRM Practices) as a dependent variable with dimensions' (Training and Development, Recruitment, Job Design, and Performance appraisal). Based on this, the correlation and effect relationships between the independent and dependent variables are determined by formulating two main hypotheses. There are a significant relationship and effect of IT competency with HRM practices within the dimensions. Furthermore, the scope and population of this research are the Informatics and Communications P
... Show More