Preferred Language
Articles
/
LhdcU44BVTCNdQwCvEKw
Performance Evaluation of Two Date Palm Frond Cutting Saws
...Show More Authors
Abstract<p>Traditional tree management is laborious and costly, thus this work aimed to study the performance of two different types of frond cutting saws (reciprocating saw and vibrating saw) and examine the two saws on five date palm varieties. Four parameters were examined, including cutting time for a single frond, the power needed for cutting a single frond, frond cutting productivity expressed as tree/h, and vibration conveyed to the worker’s hand. A field experiment was designed according to the nested randomized complete block design, including five date palm varieties as the main plot and the type of saw as a sub-plot. Means were compared using the least significant differences (LSD 0.05). Results indicated that Bream variety required the least time for frond cutting. The reciprocating saw exhibited efficiency in saving the time required for frond cutting, while the vibrating saw took significantly longer time needed for cutting a single frond. The highest number of fronds cut in one hour was recorded in Bream variety, again significantly higher than the number of other studied varieties. Moreover, the reciprocating saw achieved significantly higher productivity than the vibrating one, indicating that the productivity of the reciprocating saw is almost three times more than the vibrating saw. Maximum productivity was recorded in Bream variety, while the least was recorded in Tebarzal using the vibrating saw. Moreover, results indicate that the variety and the type of saw have a vital role in productivity since as the thickness of a frond increases, the cutting takes more time and ultimately reduces the number of date palms to be pruned per hour. Results also exhibited that vibrating saw reduced the consumed energy during frond cutting. Additionally, results revealed that the minimum power consumed by a vibrating saw was in Bream variety, while Tebarzal consumed the upmost energy when a reciprocating saw was used. Maximum vibration on X-axis was reported in Bream variety when a vibrating saw was used. Additionally, the reciprocating saw exhibited the highest vibration compared with the vibrating saw. Moreover, the reciprocating saw caused the lowest vibration in Tebarzal variety. Results indicated that the vibration imposed by both saws reached the maximum value in Bream variety. The vibrating saw resulted in the higher vibration toward Z axis, while the Reciprocating saw resulted in higher vibration toward X axis, which was more than eight times that recorded by the vibrating saw. Results indicate that vibration toward the Y axis increased significantly in Bream variety compared with others. Again, as in the situation with X and Z axis, the reciprocating saw exhibited the highest vibration compared to that resulted from using a vibrating saw which was more than three times the vibration caused by the vibrating saw.</p>
Scopus Crossref
View Publication
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Engineering
Performance Enhancement of an Air Cooled Air Conditioner with Evaporative Water Mist Pre-cooling
...Show More Authors

The present paper deals with experimental investigation of the performance of air cooled split air conditioner, with evaporative water mist pre cooling to increase the cooling capacity and reduce the consumption power under hot and dry climate. This investigation considers how the performance can be enhanced by using water mist to pre-cool ambient air entering the condensers by adiabatic cooling process which depends on the ambient air wet bulb temperature; as well the condensing temperature and condensing pressure will be decreased accordingly. So the cooling capacity would be increased and consumption power would be decreased, consequently the energy ratio, EER would be improved. The performance of air cooled air conditioner with water

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
An Investigation into Thermal Performance of Mist Water System and The Related Consumption Energy
...Show More Authors

Experimental tests were conducted to investigate the thermal performance (cooling effect) of water mist system consisting of 5μm volume median diameter droplets in reducing the heat gain entering a room through the roof and the west wall by reducing the outside surface temperature due to the evaporative cooling effect during the hot dry summer of Baghdad/Iraq. The test period
was Fifty one days during the months May, June, and July 2012. The single test day consists of 16 test hours starting from 8:00 am to 12:00 pm. The results showed a reduction range of 1.71 to 15.5℃ of the roof outside surface temperature and 21.3 to 76.6% reduction in the daily heat flux entering the room through the roof compared with the case of not using w

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 31 2017
Journal Name
Journal Of Engineering
Evaluating the Performance of High Modulus Asphalt Concrete Mixture for Base Course in Iraq
...Show More Authors

In the 1980s, the French Administration Roads LCPC developed high modulus mixtures (EME) by using hard binder. This type of mixture presented good resistance to moisture damage and improved mechanical properties for asphalt mixtures including high modulus, good fatigue behaviour and excellent resistance to rutting. In Iraq, this type of mixture has not been used yet. The main objective of this research is to evaluate the performance of high modulus mixtures and comparing them with the conventional mixture, to achieve this objective, asphalt concrete mixes were prepared and then tested to evaluate their engineering properties which include moisture damage, resilient modulus, permanent deformation and fatigue characteristics. These pro

... Show More
Publication Date
Sun Jan 01 2023
Journal Name
8th Engineering And 2nd International Conference For College Of Engineering – University Of Baghdad: Coec8-2021 Proceedings
Serviceability performance of high-strength concrete flexural members with internally unbonded post-tensioning strands
...Show More Authors

View Publication
Crossref
Publication Date
Thu Mar 12 2020
Journal Name
Al-khwarizmi Engineering Journal
Optimization the Effect of Electrode Material Change on EDM Process Performance Using Taguchi Method
...Show More Authors

Electrical Discharge Machining (EDM) is a widespread Nontraditional Machining (NTM) processes for manufacturing of a complicated geometry or very hard metals parts that are difficult to machine by traditional machining operations. Electrical discharge machining is a material removal (MR) process characterized by using electrical discharge erosion. This paper discusses the optimal parameters of EDM on high-speed steel (HSS) AISI M2 as a workpiece using copper and brass as an electrode. The input parameters used for experimental work are current (10, 24 and 42 A), pulse on time (100, 150 and 200 µs), and pulse off time (4, 12 and 25 µs) that have effect on the material removal rate (MRR), electrode wear rate (EWR) and wear ratio (WR). A

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 26 2021
Journal Name
Periodicals Of Engineering And Natural Sciences (pen)
Achieving urban sustainability by revitalizing the performance of Islamic geometric pattern on residential façades
...Show More Authors

View Publication
Scopus (3)
Scopus Crossref
Publication Date
Thu Feb 01 2018
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Performance of composite unprotected steel Beam-deck floor exposed to high temperature (fire flame)
...Show More Authors

An experimental program was conducted to determine the residual of composite Steel Beams-Reinforced Concrete (SB-RC) deck floors fabricated from a rolled steel beam topped with a reinforced concrete slab, exposed to high temperatures (fire flame) of 300, 500, and 700ºC for 1 hour, and then allowed to cool down by leaving them in the lab condition to return to the ambient temperature. The burning results showed that, by exposing them to a fire flame of up to 300ºC, no serious permanent deflection occurred. It was also noticed that the specimen recovered 93% of 19.2 mm of the deflection caused by burning. The recovered deflection of burned composite SB-RC deck floor at 500ºC was 40% of 77.9 mm of the deflection caused by burning with a res

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 30 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Improving Treatment Performance of Dissolved Air Flotation System by Using Ionic Liquids as Surfactants
...Show More Authors

The effect of three ionic liquids viz., 1-hexyl-3-methylimidazolium tetrafluoroborate (ILE), 1-hexyl-3-metylimidazolium hexafluorophosphate (ILF) and 1-octyl-3-methylimidazolium tetrafluoroborate (ILG) when used as surfactants on the performance of dissolved air floatation (DAF) was investigated.

   Experiments were conducted at a temperature of 30-35 ºC, 10ppm ferric chloride as coagulant, 50% recycle ratio, pH 8, and 10 minutes treatment time  to find oil and grease (OG) and turbidity removal efficiencies at saturation pressure (2-6) bar.

ILs were used at concentration of 50 µl/liter of treated water in two positions in DAF system; the saturation vessel and the treatment tank. The performance using ILs

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Experimental Performance of a Finned-tube Silica Gel Adsorption Chiller for Air-Conditioning Application
...Show More Authors

This work presents the construction of a test apparatus for air-conditioning application that is flexible in changing a scaled down adsorbent bed modules. To improve the heat and mass transfer performance of the adsorbent bed, a finned-tube of the adsorbent bed heat exchanger was used. The results show that the specific cooling power (SCP) and the coefficient of performance (COP) are 163 W/kg and 0.16, respectively, when the cycle time is 40 min, the hot water temperature is 90oC, the cooling water temperature is 30oC and the evaporative water temperature is 11.4oC.

View Publication Preview PDF
Publication Date
Thu May 05 2022
Journal Name
Journal Of Taibah University For Science
Innovative economic anthocyanin dye source for enhancing the performance of dye-sensitized solar cell
...Show More Authors

View Publication
Scopus (11)
Crossref (12)
Scopus Clarivate Crossref