Background : Hyperglycosylated hCG a newly discovered variant of hCG which can be used as a predictor of invasion of trophoblastic cells in patient with gestational trophoblastic disease. Objectives : To measure hyperglycosylated human chorionic gonadotrophin and to assess how far it can be used as predictor of invasion in invasive mole and choriocarcinoma. Study design control study. Setting: : Case Gynecological department in Baghdad Teaching Hospital from January 2016 to January 2017. Patient and Methods : 60 women were enrolled in this study 30 of them were with gestational trophoblastic disease (no.= 30 ) the remainder were normal pregnancy (no. =30) , hCG –H level was measured in both groups. Results : Mean serum hCG-H le
... Show MoreThe present study aims to study the correlation between visfatin levels and metabolic syndrome in Iraqi obese adolescence (with and without metabolic syndrome) and its relation with other studied biochemical parameters. Sixty obese adolescences were depended in this study (with and without metabolic syndrome), compared with (30) non-obese children as control group. This study was done in the period from April 2020 until the end of December 2020, in the National Diabetes Centre/Mustansiriya University, Baghdad/Iraq. There were no significant differences in age, height, waist circumferences (WC), and diastolic blood pressure (DBP) in the patients' groups. In contrast, a significant increase differs (p<0.05) was recorded in the values of
... Show MoreThis work is concerned with a two stages four beds adsorption chiller utilizing activated carbon-methanol adsorption pair that operates on six separated processes. The four beds that act as thermal compressors are powered by a low grade thermal energy in the form of hot water at a temperature range of 65 to 83 °C. As well as, the water pumps and control cycle consume insignificant electrical power. This adsorption chiller consists of three water cycles. The first water cycle is the driven hot water cycle. The second cycle is the cold water cycle to cool the carbon, which adsorbs the methanol. Finally, the chilled water cycle that is used to overcome the building load. The theoretical results showed that average cycle cooling power
... Show MoreFuzzy logic is used to solve the load flow and contingency analysis problems, so decreasing computing time and its the best selection instead of the traditional methods. The proposed method is very accurate with outstanding computation time, which made the fuzzy load flow (FLF) suitable for real time application for small- as well as large-scale power systems. In addition that, the FLF efficiently able to solve load flow problem of ill-conditioned power systems and contingency analysis. The FLF method using Gaussian membership function requires less number of iterations and less computing time than that required in the FLF method using triangular membership function. Using sparsity technique for the input Ybus sparse matrix data gi
... Show MoreThe aim of this study is to describe the leech species that are used in some of the alternative medicine clinics in Baghdad Province based on morphometric measurements and colouring pattern of the body. A collection of twenty leeches was provided from some clinics. All specimens were identified and described based on standard available keys. The morphometric characteristics and colouring patterns were recorded and the indicated that these leeches were Hirudo orientalis Utevsky & Trontelj, 2005 and H. verbana Carena, 1820.
The present work describes the development of code for trim and longitudinal stability analysis of a helicopter in forward flight. In general, particular use of these codes can be made for parametric investigation of the effects of the external and internal systems integrated to UH-60 helicopters. A forward flight longitudinal dynamic stability code is also developed in the work to solve the longitudinal part of the whole coupled matrix of equations of motion of a helicopter in forward flight. The coupling is eliminated by linearization. The trim analysis results are used as inputs to the dynamic stability code. The forward flight stability code is applied to UH-60 helicopter.
Two-dimensional unsteady mixed convection in a porous cavity with heated bottom wall is numerically studied in the present paper. The forced flow conditions are imposed by providing a hydrostatic pressure head at the inlet port that is located at the bottom of one of the vertical side walls and an open vent at the top of the other vertical side wall. The Darcy model is adopted to model the fluid flow in the porous medium and the combination effects of hydrostatic pressure head and the heat flux quantity parameters are carefully investigated. These governing parameters are varied over wide ranges and their effect on the heat transfer characteristics is studied in detail. It is found that the time required to reach a desired temperature at th
... Show MoreThis study delves into the realm of advanced cooling techniques by examining the performance of a two-stage parallel flow indirect evaporative cooling system enhanced with aspen pads in the challenging climate of Baghdad. The objective was to achieve average air dry bulb temperatures (43 oC) below the ambient wet bulb temperatures (24.95 oC) with an average relative humidity of 23%, aiming for unparalleled cooling efficiency. The research experiment was carried out in the urban environment of Baghdad, characterized by high temperature conditions. The investigation focused on the potential of the two-stage parallel flow setup, combined with the cooling capability of aspen pads, to surpass the limitat
... Show More