Preferred Language
Articles
/
KxdXWJMBVTCNdQwCLdEe
The Relationship between Anemia and Bone Mineral Density Measured by Dual X-Ray Absorptiometry
...Show More Authors

Background: The bone mineral density of the lumbar vertebra has been assessed according to the results of the Dual-Energy X-Ray Absorptiometry (DEXA). Although anemia is known to affect bone mineral density, at the present time, it is not clear which vertebra is more affected by this disease. Objective: To evaluate the effects of anemia on the bone mineral density of the lumbar vertebra in comparison with a normal subject and determine which part of the lumbar vertebra is more affected by anemia. Methods: All 205 participants in this study complained of bone pain (90 males and 105 females). 95 patients, including both sexes, suffered from anemia. Additionally, the study included 110 seemingly healthy volunteers as the control group. All participants were studied regarding their bone mineral density for lumbar vertebrae using dual-energy x-ray absorptiometry. Results: The DEXA outcomes revealed highly statistically significant differences between the control and patients of each lumbar vertebra in the same sex. In addition, there were significant differences in bone mineral density among the lumbar vertebrae of the same sex. Conclusions: Our findings suggest that examining the bone mineral density of the lumbar vertebrae is a more effective and appropriate method for studying the bone mineral density (BMD) of the bony skeleton in any subject, with L1 and L4 vertebrae being more susceptible to osteoporosis than other vertebrae.

Scopus Crossref
View Publication
Publication Date
Mon Sep 15 2014
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Simultaneous Determination of Ciprofloxacin Hydrochloride and Mebeverin Hydrochloride by Derivative Spectrophotometry
...Show More Authors

A new Spectrophotometric method, is for individual and simultaneous determination of Ciprofloxacin hydrochloride(CIP) and Mebeverin hydrochloride(MEB) by the first and second derivative mode techniques. The first and second derivative spectra of these compounds permitted individual and simultaneous determination of CIP and MEB in concentration range of (4-28μg/mL) by measuring the amplitude of peak- to- base line and the area under peak at selected spectrum intervals. The methods showed a reasonable precision and accuracy and have been applied to determine CIP and MEB in four different pharmaceutical preparations.

Preview PDF
Publication Date
Sat Jan 05 2019
Journal Name
Iraqi Journal Of Physics
Functionalization of single and multi-walled carbon nanotubes by chemical treatment
...Show More Authors

In this work we experimentally investigated SWCNTs and MWCNTs to increase their thermal conductivity and electrically functionalization process using different reagents ((nitric acid, HNO3 followed by acid treatment with H2SO4), then washed with deionized water (DW) and then treated with H2O2 via ultrasonic technique. Then repeated the steps with MWCNTs and compare their results in an effort to improve experimental conditions that efficiently differentiate the surface of the single walled carbon nanotubes (SWCNTs) and multi walled carbon nanotubesi(MWCNTs) that less nanotubes destroy and to enhance the properties of them and also to reduce aggregation in liquid. the results were prove by XRD, and infrared spectroscopy (FTIR). The FTIR sp

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Feb 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
Comparison of Partial Least Squares and Principal Components Methods by Simulation
...Show More Authors

Abstract                                                                                              

The methods of the Principal Components and Partial Least Squares can be regard very important methods  in the regression analysis, whe

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 15 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
Determine, Predict and Map Soil pH Level by Fiber Optic Sensor
...Show More Authors
Abstract<p>Soil pH is one of the main factors to consider before undertaking any agricultural operation. Methods for measuring soil pH vary, but all traditional methods require time, effort, and expertise. This study aimed to determine, predict, and map the spatial distribution of soil pH based on data taken from 50 sites using the Kriging geostatistical tool in ArcGIS as a first step. In the second step, the Support Vector Machines (SVM) machine learning algorithm was used to predict the soil pH based on the CIE-L*a*b values taken from the optical fiber sensor. The standard deviation of the soil pH values was 0.42, which indicates a more reliable measurement and the data distribution is normal.</p> ... Show More
View Publication
Scopus (12)
Crossref (4)
Scopus Crossref
Publication Date
Mon Mar 11 2019
Journal Name
Baghdad Science Journal
Determination of Nicotine Extracted from Eggplant and Green Pepper by HPLC
...Show More Authors

Nicotine was separated from eggplant and green pepper seeds (Solanaceous) by High Performance Liquid Chromatography (HPLC).The concentration of nicotine in the eggplant extract (0.871-0.877 μg/ml) was determined by injecting standard material with 0.5 and 1.5 μg/ml, while the concentrations of nicotine in green pepper extract (0.613-0.618 μg/ml) was determined when the standard material was injected with 0.5 and 1.5 μg/ml. The qualitative chemical data was calculated from derivations of the standard material. Nicotine concentration was measured qualitatively in both extracts through the calibration curve and method of the standard addition. This technique has high accuracy and compatibility, bringing the proportion of relati

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Sun Aug 01 2021
Journal Name
Bulletin Of Electrical Engineering And Informatics
Robust speaker verification by combining MFCC and entrocy in noisy conditions
...Show More Authors

Automatic speaker recognition may achieve remarkable performance in matched training and test conditions. Conversely, results drop significantly in incompatible noisy conditions. Furthermore, feature extraction significantly affects performance. Mel-frequency cepstral coefficients MFCCs are most commonly used in this field of study. The literature has reported that the conditions for training and testing are highly correlated. Taken together, these facts support strong recommendations for using MFCC features in similar environmental conditions (train/test) for speaker recognition. However, with noise and reverberation present, MFCC performance is not reliable. To address this, we propose a new feature 'entrocy' for accurate and robu

... Show More
View Publication Preview PDF
Scopus (16)
Crossref (10)
Scopus Crossref
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Economics And Administrative Sciences
A Comparison Between Some Estimator Methods of Linear Regression Model With Auto-Correlated Errors With Application Data for the Wheat in Iraq
...Show More Authors

This research a study model of linear regression problem of autocorrelation of random error is spread when a normal distribution as used in linear regression analysis for relationship between variables and through this relationship can predict the value of a variable with the values of other variables, and was comparing methods (method of least squares, method of the average un-weighted, Thiel method and Laplace method) using the mean square error (MSE) boxes and simulation and the study included fore sizes of samples (15, 30, 60, 100). The results showed that the least-squares method is best, applying the fore methods of buckwheat production data and the cultivated area of the provinces of Iraq for years (2010), (2011), (2012),

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Feb 03 2018
Journal Name
Chinese Journal Of Physics
A true random number generator based on the photon arrival time registered in a coincidence window between two single-photon counting modules
...Show More Authors

True random number generators are essential components for communications to be conconfidentially secured. In this paper a new method is proposed to generate random sequences of numbers based on the difference of the arrival times of photons detected in a coincidence window between two single-photon counting modules

View Publication
Scopus (19)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2018
Journal Name
World Journal Of Dentistry
Obturation of Lateral Canals by a New Reciprocating Spreader and a Conventional Finger Spreader by Lateral Condensation Technique: in vitro Comparative Study
...Show More Authors

View Publication
Scopus (2)
Scopus
Publication Date
Sat Sep 23 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Direct Estimation for Approximation by Bernstein Polynomial by Using Ditzian-Totik and Average in L Ja,h11 p < oo Modulus of Smoothness
...Show More Authors

The  purpose  of  the  paper  is  to  tind  the  degree  of  the approximation of a functions  f be bounded , measurable and defined

in  interval   [a,h]by  Bernstein  polynomial  in  LP    space  1 $ p < oo by

 

using Ditzian-Totik modulus  of smootlmess  and  k 1n  average modvlus of smoothness.

View Publication Preview PDF