The Relationship between Anemia and Bone Mineral Density Measured by Dual X-Ray Absorptiometry
...Show More Authors

Background: The bone mineral density of the lumbar vertebra has been assessed according to the results of the Dual-Energy X-Ray Absorptiometry (DEXA). Although anemia is known to affect bone mineral density, at the present time, it is not clear which vertebra is more affected by this disease. Objective: To evaluate the effects of anemia on the bone mineral density of the lumbar vertebra in comparison with a normal subject and determine which part of the lumbar vertebra is more affected by anemia. Methods: All 205 participants in this study complained of bone pain (90 males and 105 females). 95 patients, including both sexes, suffered from anemia. Additionally, the study included 110 seemingly healthy volunteers as the control group. All participants were studied regarding their bone mineral density for lumbar vertebrae using dual-energy x-ray absorptiometry. Results: The DEXA outcomes revealed highly statistically significant differences between the control and patients of each lumbar vertebra in the same sex. In addition, there were significant differences in bone mineral density among the lumbar vertebrae of the same sex. Conclusions: Our findings suggest that examining the bone mineral density of the lumbar vertebrae is a more effective and appropriate method for studying the bone mineral density (BMD) of the bony skeleton in any subject, with L1 and L4 vertebrae being more susceptible to osteoporosis than other vertebrae.

Scopus Crossref
View Publication
Publication Date
Fri Feb 28 2020
Journal Name
Neuroquantology
Using X-Ray Films for Evaluation efficiency of Unsaturated Polyester Reinforced by Lead Oxide as Shielding for Medical X-ray Devices
...Show More Authors

The largest use of x-ray in medical by dentists, employers or persons that needed by patients with specific conditions, lead to higher exposure of x-ray that may cause many diseases. In the present work radiography films have been used in evaluating the efficiency of using unsaturated polyester polymer reinforced with lead oxide (PbO) as shield material for medical x-ray devices, many parameters studied like concentration and thickness that they are increasing the attenuation of x-ray in them. The results show that the attenuation of X-ray increasing with concentration of reinforced material and with thickness, and the optical density decreases with increasing concentration from 0% to 50%, we chose 30% as suitable concentration to increase

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Jun 30 2012
Journal Name
Al-kindy College Medical Journal
Treatment of Nasopharyngeal Carcinoma by Using Deep X-Ray Therapy
...Show More Authors

Background: Nasopharyngeal carcinoma (NPC) is one of the most challenging tumors because of their relative inaccessibility and that their spread can occur without significant symptoms with few signs, but Radiotherapy (RT) has a role in treatment of it.
Objectives: To show that RT is still the modality of choice in the treatment of NPC, to study modes of presentations, commonest histopathological types and their percentages, to show differences in the sensitivities of these types to RT and to find out a 5 year survival rate(5YSR) and its relation with lymph node involvement.
Methods: This is a retrospective study of 44 patients with NPC who were treated with routine RT from 1988-2007 at the institute of radiology and nuclear medicin

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 05 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
X-Ray Fluorescence Determination of Trace Elements in Vitamin-Mineral Complexes and Medicinal Herbs Using Chemically Modified Polyurethane Foam Sorbents
...Show More Authors

In this paper we proposed the method of X-ray fluorescence (XRF) determination of some essential trace elements in medicinal herbs and vitamin-mineral complexes at the level of 100-101 mg/ml. To increase sensitivity and selectivity of the determination we simple and effective approach based on the extraction of metal ions from aqueous solutions with chemically modified polyurethane foam sorbents followed by direct XRF analysis. The conditions of sorption preconcentration of Co(II), Ni(II) and Zn(II) ions with modified sorbents were optimized. The proposed approach is used for the determination of trace elements in several kinds of medicinal herbs (coltsfoot leaves, nettle leaves and yarrow herb) and vitamin-mineral

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Corrеlation bеtwееn Dual-Еnеrgy X-Ray Absorptiomеtry and Panoramic Mandibular Indicеs in Prеdiction of Bonе Minеral Dеnsity in Postmеnopausal Fеmalеs
...Show More Authors

Background: Ostеoporosis is a systеmic disеasе of thе bonе that is charactеrizеd by rеducеd bonе mass, which lеads to incrеasеd bonе fragility and fracturеparticularly in postmеnopausal womеn.Thе aims of study was toеvaluatе thе rеlationship bеtwееn mandibular radiomorphomеtric indicеs obtainеd on digital panoramic radiographswith thе bonе minеral dеnsitiеs of thе lumbar spinееvaluatеd using dual-еnеrgy X-ray absorptiomеtry (DXA) scan, in a population of ostеoporotic and non-ostеoporotic fеmalеs. Matеrials and mеthods: In panoramic imagеs obtainеd from 60 fеmalе individuals dividеd еq

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Iraqi Journal Of Physics
Radiation contrast improvement by suitable choice of x-ray radiation spectrum
...Show More Authors

Different bremsstrahlung spectra from tungsten anode x-ray tube generated at 30, 40 and 50 kV have been examined theoretically and experimentally for an attempt to find a most suitable spectrum to radiograph a test object of 0.01 cm thickness of Cu and Ag. The high contrast using this suitable spectrum is demonstrated and the possible effects of fluorescent radiation are discussed.

View Publication Preview PDF
Publication Date
Wed Feb 01 2023
Journal Name
Indonesian Journal Of Electrical Engineering And Computer Science
Diagnose COVID-19 by using hybrid CNN-RNN for Chest X-ray
...Show More Authors

<p>Combating the COVID-19 epidemic has emerged as one of the most promising healthcare the world's challenges have ever seen. COVID-19 cases must be accurately and quickly diagnosed to receive proper medical treatment and limit the pandemic. Imaging approaches for chest radiography have been proven in order to be more successful in detecting coronavirus than the (RT-PCR) approach. Transfer knowledge is more suited to categorize patterns in medical pictures since the number of available medical images is limited. This paper illustrates a convolutional neural network (CNN) and recurrent neural network (RNN) hybrid architecture for the diagnosis of COVID-19 from chest X-rays. The deep transfer methods used were VGG19, DenseNet121

... Show More
View Publication
Scopus (17)
Crossref (2)
Scopus Crossref
Publication Date
Fri Apr 21 2023
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees22fr
Modified x-ray analysis size strain plot method to determine the lattice stress and strain energy density of calcium titan oxide (CaTiO3) nanoparticles
...Show More Authors

In this research, the size strain plot method was used to estimate the particle size and lattice strain of CaTiO3 nanoparticles. The SSP method was developed to calculate new variables, namely stress, and strain energy, and the results were crystallite size (44.7181794 nm) lattice strain (0.001211), This method has been modified to calculate new variables such as stress and its value (184.3046308X10-3Mpa) and strain energy and its value (1.115833287X10-6 KJm-3).

View Publication
Scopus Crossref
Publication Date
Wed Jul 17 2019
Journal Name
Aip Conference Proceedings
The correction of the line profiles for x-ray diffraction peaks by using three analysis methods
...Show More Authors

In this study used three methods such as Williamson-hall, size-strain Plot, and Halder-Wagner to analysis x-ray diffraction lines to determine the crystallite size and the lattice strain of the nickel oxide nanoparticles and then compare the results of these methods with two other methods. The results were calculated for each of these methods to the crystallite size are (0.42554) nm, (1.04462) nm, and (3.60880) nm, and lattice strain are (0.56603), (1.11978), and (0.64606) respectively were compared with the result of Scherrer method (0.29598) nm,(0.34245),and the Modified Scherrer (0.97497). The difference in calculated results Observed for each of these methods in this study.

View Publication
Scopus (12)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Thu May 10 2018
Journal Name
Global Journal Of Health Science; Issn 1916-9736 E-issn 1916-9744
Effects of Biological and Non Biological Agents (Disease Modifying Antirheumatic Drugs) on Bone Mineral Density in a Sample of Rheumatoid Arthritis Patients
...Show More Authors

Background: Osteoporosis is an extra-articular complication of rheumatoid arthritis that results in increased risk of fractures and associated morbidity, mortality, and healthcare costs. Objective: To evaluate changes in bone mineral density in a sample of rheumatoid arthritis (RA) patients on biological (anti tumor necrosis factor (TNF) alpha) and non-biological agent disease modifying antirheumatic drugs (DMARDs). Patients and Methods: A cross sectional study enrolled 60 RA patients diagnosed by rheumatologist according to the 2010 American College of Rheumatology/European League Against Rheumatism (2010 ACR/EULAR) classification criteria for RA. Thirty patient on biological agent (anti TNF alpha) and 30 patient on non-biological agent (D

... Show More
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Oral Contraceptive Pill on Cortical Thickness and Bone Mineral Density of The Mandibular Mental and Gonial Regions in Premenopausal Females Using Spiral Computed Tomography
...Show More Authors

Background: Prolonged use of low-dose estrogen ''20 micrograms or less" Combined oral contraceptive pill (that have estrogen and progesterone steroid hormone) had an effect on bone turnover .Bone mineral density is used in clinical medicine as an indirect indicator of osteoporosis and fracture risk. The aim of the study: The aim of this study was to investigate the effect of low dose oral contraceptive pill on the cortical thickness (in millimeter) and bone mineral density at the mandibular cortex of mental and gonial regions in Hounsfield unit(HU) using spiral computed tomography. Material and method: This prospective study was conducted on computed tomographic image of 100 women aged between (20-40) years .The collected sample includes

... Show More
View Publication Preview PDF