Preferred Language
Articles
/
KhZRWocBVTCNdQwCQEeV
Diode Laser Versus Scalpel Gingivectomy
...Show More Authors

Background: different methods can be used to remove tissue during gingivectomy and produce a good gingival margin, the most common is the conventional gingivectomy which is done by the use of scalpel, now a day’s Laser is widely spread and can be used to perform surgeries. Materials and methods: 50 patients divided into two equal groups, Group 1 gingivectomy was done by Diode Laser, Group 2 gingivectomy was done by scalpel, plaque and gingival index were measured at 1st, 2nd and 3rd visit, swab were taken and sent foe detecting bacterial growth and biopsy were taken for histopathological examination. Group 1 show no significant differences in plaque and gingival means between the visits, the bacteriological examination showed no growth of bacteria and histological examination revealed less inflammatory cells than Group 2. Group 2 show significant differences in plaque and gingival indices between the visits. Though scalpel remains the gold standard choice in gingivectomy but Diode laser may have some advantages over it.

Crossref
View Publication
Publication Date
Wed Jan 30 2013
Journal Name
Al-kindy College Medical Journal
Coronary Angiographic Findings in Diabetic Patients Versus non-Diabetics with Coronary Heart Disease
...Show More Authors

Background :Atherosclerosis is the most
frequent underlying cause of ischemic heart
disease and a major cause of death all over the
world. This study was carried out to analyze and
compare the angiographic findings in patients
with diabetes mellitus versus non diabetics with
coronary heart disease , and to correlate these
findings with some risk factors for coronary
heart disease.
Methods: A total of 100 patients were studied,
50 with diabetes mellitus, and 50 non diabetics.
This study was carried out at Al-Sadr teaching
hospital in Basrah, Southern Iraq during the
period April 2009- September 2009. All patients
were known to have coronary heart disease. Risk
factors for coronary heart disease

... Show More
View Publication
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
K. wire fixation versus conservative treatment of closed displaced intra-articular calcaneal fractures
...Show More Authors

Background: Calcaneus is a spongy cancellous bone with rich blood supply , its fracture heals more rapidly providing no occurrence of infection and soft tissue injury around ,no gross malposition of fragments. The associated pain leads to a major impairment in life quality. The aim of treatment for calcaneal fractures is the decrease of pain and rebuilding of walking ability for patients with normal foot shape and the ability to wear normal foot wear. To reduce complications, a minimally invasive technique for the treatment of displaced intra-articular fractures of the calcaneus was preferred to use. The purpose of this study was to determine whether the closed reduction and percutaneous K. wire fixation of displaced intra-art

... Show More
Preview PDF
Crossref
Publication Date
Tue Jun 30 2009
Journal Name
Al-kindy College Medical Journal
Psychiatric Squele of Sodium Valproate Versus Carbamazipine in Patients with Primary Generalized Epilepsy
...Show More Authors

Background: psychiatric and behavioral side effects are
common in patients with epilepsy and it may represent an
intrinsic feature of the disease itself or a side effect of the
antiepileptic use. Our aim in the present study is to assess
the psychiatric side effects of Sodium Valproate and
Carbamazipine .as these drugs are the most commonly
used antiepileptic drugs in Iraq.
Methods: 80 patients with primary generalized epilepsy
on Carbamazipine and 50 patients on Sodium Valproate
were enrolled in the present study; all the patients were
assessed for any psychological disturbances using semistructural interview based on the tenth edition of the
international classification of the diseases(ICD 10)
adopte

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 31 2016
Journal Name
Al-kindy College Medical Journal
Non Traumatic Hip Osteonecrosis Treated By Non Vascularised Bone Graft Versus Core Decompression
...Show More Authors

Background: Avascular necrosis (AVN) is defined as cellular death of bone components due to interruption of the blood supply; the bone structures then collapse, resulting in bone destruction, pain, and loss of joint function. AVN is associated with numerous conditions and usually involves the epiphysis of long bones, such as the femoral head. In clinical practice, AVN is most commonly encountered in the hip. Early diagnosis and appropriate intervention can delay the need for joint replacement. However, most patients present late in the disease course. Without treatment, the process is almost always progressive, leading to joint destruction within 5 years.Treatment of a vascular necrosis depends mainly on early diagnosis which mainly base

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jul 01 2025
Journal Name
Nigerian Postgraduate Medical Journal
Private versus Public Hospitals: Patient Satisfaction of Nursing Care Quality in Orthopaedic Wards
...Show More Authors
Background:

Patient’s satisfaction with nursing care is thought to be a key component in determining how patients perceive service quality. Quantifying patient satisfaction in both private and public healthcare settings can offer essential evidence on performance; consequently, reflected on quality management.

Aims:

This study aims to explore patients’ satisfaction with the quality of nursing care.

Subjects and Methods:

A descriptive-cross-sectional study

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
Nanosecond laser pulses for aluminum and copper drilling
...Show More Authors

Nd:YAG laser pulses of 9 nanosecond pulse duration and operating wavelength at 1.06 μm, were utilized to drill high thermal conductivity and high reflectivity aluminum and copper foils. The results showed a dependence of drilled holes characteristics on laser power density and the number of laser pulses used. Drilled depth of 74 ϻm was obtained in aluminum at 11.036×108 W/cm2 of laser power density. Due to its higher melting point, copper required higher laser power density and/or larger number of laser pulses to melt, and a maximum depth of 25 μm was reached at 13.46×108 W/cm2 using single laser pulse.

View Publication Preview PDF
Crossref
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Physics
Laser wavelength and energy effect on optical and structure properties for nano titanium oxide prepared by pulsed laser deposit
...Show More Authors

Nano TiO2 thin films on glass substrates were prepared at a constant temperature of (373 K) and base vacuum (10-3 mbar), by pulsed laser deposition (PLD) using Nd:YAG laser at 1064 nm wavelength. The effects of different laser energies between (700-1000)mJ on the properties of TiO2 films was investigated. TiO2 thin films were characterized by X-ray diffraction (XRD) measurements have shown that the polycrystalline TiO2 prepared at laser energy 1000 mJ. Preparation also includes optical transmittance and absorption measurements as well as measuring the uniformity of the surface of these films. Optimum parameters have been identified for the growth of high-quality TiO2 films

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Baghdad Science Journal
New Spectral Range Generations from Laser-plasma Interaction
...Show More Authors

            High-intensity laser-produced plasma has been extensively investigated in many studies. In this demonstration, a new spectral range was observed in the resulted spectra from the laser-plasma interaction, which opens up new discussions for new light source generation. Moreover, the characterizations of plasma have been improved through the interaction process of laser-plasma. Three types of laser were incorporated in the measurements, continuous-wave CW He-Ne laser, CW diode green laser, pulse Nd: YAG laser. As the plasma system, DC glow discharge plasma under the vacuum chamber was considered in this research. The plasma spectral peaks were evaluated, where they refer to Nitrogen gas. The results indicated that the

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees19gr
Superconductor enhancements by laser irradiations
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Aip Conference Proceedings
Superconductor enhancements by laser irradiations
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Crossref