Moisture-induced damage is one of the primary causes of premature distress in asphalt pavements, leading to reduced service life and increased maintenance costs. Although nanomaterials have shown potential in enhancing asphalt performance, the underlying composite interaction mechanisms among nanomaterials, asphalt binder, and aggregate phases under moisture exposure are still not fully understood. In addition, comparative evaluations under consistent experimental conditions remain limited. This study investigates the influence of five nanomaterials: nano-silica (NS), nano-alumina (NA), nano-titanium dioxide (NT), nano-zinc oxide (NZ), and carbon nanotubes (CNT) on the physical and mechanical properties of asphalt binders and mixtures, with particular emphasis on moisture damage resistance. The nanomaterials were incorporated at dosages of 1.5%, 3.0%, 4.5%, and 6.0% by binder weight. Binder performance was evaluated using conventional and performance grading (PG) tests, while mixture performance was assessed through Marshall properties and moisture susceptibility indicators, including the tensile strength ratio (TSR) and the index of retained strength (IRS). Fluorescence microscopy (FM), scanning electron microscopy (SEM), and Fourier transform infrared spectroscopy (FTIR) were employed to investigate nanomaterial dispersion characteristics, microstructural morphology, and physicochemical interactions within the asphalt composite system. The results indicate that nanomaterial modification reduced penetration and increased softening point and Marshall stability, reflecting enhanced stiffness and thermal resistance, although ductility decreased at higher dosages. Significant improvements in moisture resistance were observed, particularly under conditioned states. The TSR increased from 81.2% for the control mixture to 92.4% for NS and 91.7% for NA, while the IRS improved from 72.7% to 88.5% for NS. Statistical analysis indicated that both nanomaterial type and dosage significantly affected TSR and IRS performance, with dosage exhibiting comparatively greater influence on moisture resistance improvement. FM and SEM analyses revealed comparatively better dispersion and lower agglomeration tendency for NS and NA, which corresponded to their superior moisture resistance performance. FTIR analysis indicated that the modification process was predominantly physical, with no major formation of new chemical functional groups. Among the investigated nano materials, NS at 6% dosage exhibited the most pronounced improvement, followed by NA at similar dosage levels. Overall, the findings suggest that nanomaterial modification can considerably improve the moisture resistance and mechanical performance of asphalt mixtures under laboratory conditions. However, higher nanomaterial dosages may adversely affect binder workability due to increased viscosity, particularly in CNT-modified binders.
Background: Polymeric composites have been widely used as dental restorative materials. A fundamental knowledge and understanding of the behavior of these materials in the oral cavity is essential to improve their properties and performance. The goal of this study was to measure water sorption of four composite resins containing different filler and resin matrix contents. Materials and method: Resin composite specimens giomer (Beautifil II) Filtek™ P90, Filtek™ Z350 XT, and Tetric N Ceram were prepared in a cylindrical mould of 3mm thickness and 6mm diameter (n=10) and light cured . All specimens placed in silica-gel desiccators at 37˚C for seven days, a constant weight was obtained. All samples were immersed in deionized distill
... Show MoreConfocal microscope imaging has become popular in biotechnology labs. Confocal imaging technology utilizes fluorescence optics, where laser light is focused onto a specific spot at a defined depth in the sample. A considerable number of images are produced regularly during the process of research. These images require methods of unbiased quantification to have meaningful analyses. Increasing efforts to tie reimbursement to outcomes will likely increase the need for objective data in analyzing confocal microscope images in the coming years. Utilizing visual quantification methods to quantify confocal images with naked human eyes is an essential but often underreported outcome measure due to the time required for manual counting and e
... Show MoreBasrah crude oil Vacuum residue 773+ K with specific gravity 1.107 and 4.87wt. % sulfur, was treated with hexane commercial fraction provided from Al-Taji Gas Company for preparing deasphaltened oil(DAO)suitable for hydrotreating process. Deasphaltening was carried out with 1h mixing time, 10ml:1g solvent to oil ratio and at room temperature. Hexane deasphaltened oil was hydrotreated on presulfied commercial Co-Mo/γ-Al2O3 catalyst in a trickle bed reactor. The hydrotreating process was carried out at temperature 660 K,LHSV 1.3 h^ –1, H2/oil ratio 300 l/l and constant pressure of 4MPa. The hydrotreated product was distillated under vacuum distillation unit. It is found that the mixture of 75% of vacuum residue with 25% anthracene satisfie
... Show MoreThe problem of internal sulfate attack in concrete is widespread in Iraq and neighboring countries.This is because of the high sulfate content usually present in sand and gravel used in it. In the present study the total effective sulfate in concrete was used to calculate the optimum SO3 content. Regression models were developed based on linear regression analysis to predict the optimum SO3 content usually referred as (O.G.C) in concrete. The data is separated to 155 for the development of the models and 37 for checking the models. Eight models were built for 28-days age. Then a late age (greater than 28-days) model was developed based on the predicted optimum SO3 content of 28-days and late age. Eight developed models were built for all
... Show MoreThis study aims to assess the removal efficiency andestablish the BOD5 and COD statisticalcorrelation of the sewage flowing in Al-Diwaniyah wastewater treatment plant in Iraq during the study period (2005-2016). The strength of the influent wastewater entering the plant varied from medium to high in strength. High concentrations of BOD5 and COD in the effluent were obtained due to the poor performance of the plant. This was observed from the BOD5 /COD ratios that did not confirm with the typical ratios for the treated sewage. To improve the performance of this plant, regression equations for BOD5 and COD removal percentages were suggested which can be used to facilitate evaluation of liquid waste and optimal control process. The equations
... Show More