Pregnancy and childbirth are physiological states characterized by sudden hormonal and immunologically described changes. The current study aimed to investigate the influence of maternal variables (age, previous abortion, placental position, and fetal position) on some physiological biomarkers, such as oxytocin (OT), prolactin (PRL), cortisol, and insulin growth factor 2 (IGF -2) and some immune biomarkers such as programmed cell death protein 1 (PD-1), programmed cell death ligand 1 (PD-L1) and interleukin 6 (IL-6) in Iraqi women undergoing caesarean section (CS). Blood samples were collected from 48 pregnant women in the age range (16-43 years) and serum was obtained to determine the levels of the above biomarkers. The effect of maternal age on physiological biomarkers showed that OT levels increased significantly with maternal age (P≤0.001), whereas PRL, cortisol, and IGF-2 levels were not (P˃0.05), showing differences between age categories. The effect of maternal age on immune biomarkers showed that PD-1 levels decreased significantly (P<0.05) and PD-L1 and PD-1/PD-L1 levels were highly significant (P≤ 0.001), however, IL-6 level shows a non-significant (P˃0.05) difference between age categories. Regarding the effect of previous abortion, statistical analysis showed that cortisol levels were significantly (P<0.05) lower in women with previous abortion compared to women without previous abortion, while OT, PRL, and IGF-2 levels were not significantly different (P ˃ 0.05) difference between the two groups. PD-1 and PD-L1 levels showed a significant (P<0.05) decrease in women with previous abortion compared with women without abortion, while IL-6 mirror images did not differ significantly (P˃0.05) between the two groups. The effect of placenta position showed that when the placenta was in the anterior position, the PRL level was significantly increased (P≤0.001), IGF-2 level was significantly decreased (P<0.05), while the OT and cortisol levels were significantly higher (P≤0.001) compared with the posterior position There was no significant difference between the two groups (P˃0.05). When the placenta was located in the anterior compared with the posterior, the level of PD-L1 was significantly (P<0.05) lower, while the levels of PD-1 and PD -1/PD- were not significantly different (P˃0.05). L1 and IL-6 between the two groups. According to fetal position, statistical analysis showed no significant difference in all physiological and immune biomarkers when the fetus was in cephalic or breech position (P˃0.05). It can be concluded that the more maternal variables which affect on the physiological and immunological biomarkers of the women undergoing caesarean section are maternal age and a previous abortion.
The aim of this study was to know ( the impact of education differentiated strategy to modify the alternative developments of geographical concepts when students first grade average) .
To achieve the goal of this study , researcher relied on the experimental design of a partial set , the design is ( the experimental group with a control group of post-test ).
&nbs
... Show MoreThis study discussed a biased estimator of the Negative Binomial Regression model known as (Liu Estimator), This estimate was used to reduce variance and overcome the problem Multicollinearity between explanatory variables, Some estimates were used such as Ridge Regression and Maximum Likelihood Estimators, This research aims at the theoretical comparisons between the new estimator (Liu Estimator) and the estimators
Background: This in vitro study compares a novel calcium-phosphate etchant paste to conventional 37% phosphoric acid gel for bonding metal and ceramic brackets by evaluating the shear bond strength, remnant adhesive and enamel damage following water storage, acid challenge and fatigue loading. Material and Methods: Metal and ceramic brackets were bonded to 240 extracted human premolars using two enamel conditioning protocols: conventional 37% phosphoric acid (PA) gel (control), and an acidic calcium-phosphate (CaP) paste. The CaP paste was prepared from β-tricalcium phosphate and monocalcium phosphate monohydrate powders mixed with 37% phosphoric acid solution, and the resulting phase was confirmed using FTIR. The bonded premolars were exp
... Show More<span lang="EN-US">The fundamental of a downlink massive multiple-input multiple-output (MIMO) energy- issue efficiency strategy is known as minimum mean squared error (MMSE) implementation degrades the performance of a downlink massive MIMO energy-efficiency scheme, so some improvements are adding for this precoding scheme to improve its workthat is called our proposal solution as a proposed improved MMSE precoder (PIMP). The energy efficiency (EE) study has also taken into mind drastically lowering radiated power while maintaining high throughput and minimizing interference issues. We further find the tradeoff between spectral efficiency (SE) and EE although they coincide at the beginning but later their interests become con
... Show MoreSolid‐waste management, particularly of aluminum (Al), is a challenge that is being confronted around the world. Therefore, it is valuable to explore methods that can minimize the exploitation of natural assets, such as recycling. In this study, using hazardous Al waste as the main electrodes in the electrocoagulation (EC) process for dye removal from wastewater was discussed. The EC process is considered to be one of the most efficient, promising, and cost‐effective ways of handling various toxic effluents. The effect of current density (10, 20, and 30 mA/cm2), electrolyte concentration (1 and 2 g/L), and initial concentration of Brilliant Blue dye (15 and 30 mg/L) on
We studied the effect of certain environmental conditions for removing heavy metal elements from contaminated aqueous solutions (Cd, Cu, Pb, Fe, Zn, Ni, Cr) using the bacterium Bacillus subtilis to appoint the optimal conditions for removal ,The best optimum temperature range for two isolate was 30-35○C while the hydrogen number for the maximum mineral removal range was 6-7. The best primary mineral removal was 100 mg/L, while the maximum removal for all minerals was obtained after 6 hrs of Cu element time and the maximum removal efficiency was obtained after 24 hrs of Cu element. The results have proved that the best aeration for maximum removal was obtained at rotation speed of 150 rpm/minute. Inoculums of 5ml/100ml which contained 1
... Show More