The PET scans provide images that pinpoint the anatomic location of abnormal metabolic activity within the body. A radionuclide suitable for labeling a wide range of radiopharmaceuticals for positron emission tomography imaging is used also for local therapy of tumors. Among the possible methods for cyclotron production of radionuclide used in PET. We investigate the proton irradiation to produce the standard radionuclide (15O, 11C,1 3N, 18F) and some non-standard Radionuclide (76Br,124I,60Cu,66Ga,86Y and 89Zr). The total integral yield based on the main published and approved experimental results of excitation functions were calculated.
The research aims at identifying the extent to which the top management in the organization is interested in managing the talents of its employees, through which it can face the competing organizations, as well as the great challenges faced by all organizations in recent years. The task of attracting and maintaining talented human resources is one of the biggest challenges facing Organizations
... Show More
CR-39 is a solid state nuclear track detector (SSNTD) that has been used in many research areas. In spite of the assumption that the CR-39 detectors are insensitive to beta and gamma rays, irradiation with these rays can have significant effects on the detector properties. In this study, beta and gamma rays mass attenuation coefficients μ/ρ (cm2 g-1) for the CR-39 detector have been measured using NaI(Tl) scintillation spectrometer along with a standard geometrical arrangement in the energy region of (0.546-2.274) MeV beta rays and standard gamma sources having energy 0.356, 0.5697, 0.6617 and 1.063 MeV. The total atomic cross-section (σtot), total electronic cross-section (σT E) and the effective atomic number (Zeff) of gamma rays a
... Show MoreIn this paper the specific activity of 238U, 232Th and 40K
radionuclides were determined by sodium iodide enhanced by
thallium NaI(Tl) detector and assessment the annual effective dose
in samples of powder milk from different companies such as
Almunaish, Seven Caw, Molty and Altunsa for adult available in
Baghdad markets. The specific activity of 40K has the greater value in
all the samples which is in the range of allowed levels globally that
suggested by UNSCEAR. The mean value of annual effective doses
were 0.121, 0.314775 and 0.305 mSv/y for 238U, 232Th and 40K
respectively.
Building numerical reservoir simulation model with a view to model actual case requires enormous amount of data and information. Such modeling and simulation processes normally require lengthy time and different sets of field data and experimental tests that are usually very expensive. In addition, the availability, quality and accessibility of all necessary data are very limited, especially for the green field. The degree of complexities of such modelling increases significantly especially in the case of heterogeneous nature typically inherited in unconventional reservoirs. In this perspective, this study focuses on exploring the possibility of simplifying the numerical simulation pr
Polarization manipulation elements operating at visible wavelengths represent a critical component of quantum communication sub-systems, equivalent to their telecom wavelength counterparts. The method proposed involves rotating the optic axis of the polarized input light by an angle of 45 degree, thereby converting the fundamental transverse electric (TE0) mode to the fundamental transverse magnetic (TM0) mode. This paper outlines an integrated gallium phosphide-waveguide polarization rotator, which relies on the rotation of a horizontal slot by 45 degree at a wavelength of 700 nm. This will ultimately lead to the conception of a mode hybridization phenomenon in the waveguide. The simulation results demonstrate a polarization co
... Show More