This research included the study of different factors that may effect on gatifloxacin stability (anew quinolone synthetic antibacterial agent) in its aqueous solution in order to develop and optimize the best delivary of the drug to the eye (as eye drop) with maximum local concentration and minimum systemic absorption and toxicity.Different formulas of gatifloxacin solution for ophthalmic use (0.3%)w/v were prepared in citrate, acetate,citrate/phosphate and phosphate buffers,their tonicity adjusted with suitable quantity of sodium chloride.The effect of different factors that might affectthe stability of gatifloxacin in its prepared ophthalmic solution was studied and determined spectrophotometrically at 287 nm. The results showed that The use of disodium edetate as asequestering agent gave more stable formula and gatifloxacin undergoes hydrolysis at low pH with optimum stability at pH 6.0, which is the most suitable pH for this ophthalmic solution. The type of buffer significantlyaffects on the rate of hydrolysis of gatifloxacinspecially at low pH and optimum stability was obtained by using phosphate buffer. The concentration of phosphate buffer had a significant effect on the hydrolysis of gatifloxacin and the rate of hydrolysis increased as the concentration buffer increased. Ionic strength affects the hydrolysis rate of gatifloxacin and the hydrolysis increased as the ionic strength increased. Light had a significant effect on the rate of hydrolysis of the drug and the drug losses 10% of its potency after 10 monthes of light exposure at room temperature. The prepared formula J ( gatifloxacin 0.3% in 0.1M phosphate buffer with sodium chloride 0.26% , xanthan gum 0.2% and disodium edetate 0.01%) is thebest stable one and had no irritation on the eye of experimental animals, and it passes successfully quality control tests including: drug content, pH, clarity and sterility test and comply with united state pharmacopoeia for ophthalmic solutions.
Experimental study has been conducted for laminar natural convection heat transfer of air flow through a rectangular enclosure fitted with vertical partition. The partition was oriented parallel to the two vertical isothermal walls with different temperatures, while all the other surfaces of the enclosure were insulated. In this study a test rig has been designed and constructed to allow studying the effect of Rayleigh number, aperture height ratio, partition thickness, the position of aperture according to the side walls and according to the height, the position of the partition according to the hot wall, and partition inclination. The experiments were carried out with air as the working fluid for Rayleigh number range (5*107 – 1.3*10
... Show MoreMilling process is a common machining operation that is used in the manufacturing of complex surfaces. Machining-induced residual stresses (RS) have a great impact on the performance of machined components and the surface quality in face milling operations with parameter cutting. The properties of engineering material as well as structural components, specifically fatigue life, deformation, impact resistance, corrosion resistance, and brittle fracture, can all be significantly influenced by residual stresses. Accordingly, controlling the distribution of residual stresses is indeed important to protect the piece and avoid failure. Most of the previous works inspected the material properties, tool parameters, or cutting parameters, bu
... Show MoreAn experimental study was carried out for an evaporative cooling system in order to investigate the effect of using an aluminum pad coated with fabric polyester. In the present work, it was considered to use a new different type of cooling medium and test its performance during the change in the wet-bulb temperature and dry-bulb temperature of the supply air outside of the pad, the relative humidity of the supply air, the amount of air supplied (300-600) CFM and also the change of the amount of circulated water (1.75, 2.5, 4.5) liter per minute. A decrease in the WBT of the air was obtained, whereas the WBT of the air entering the pad was 26.5 . In contrast, the WBT of the outside air had reached 23 even though eva
... Show MoreThirteen isolates were collected from various clinical sources during the periodfrom 22/10/2017 to 22/12/2017. All the isolates were diagnosed based on the microscopic and biochemical propertiesby Vitek-2 Compact system. All isolates formed biofilm 100%, with 30% of isolatesbiofilm produced strongly and 70% on medium. The results of the present study have shown the presence of Curli fimbriae genes in E. cloacae bacteria from cases of urinary tract infections, infected patient with blood bacteremia and inflammation of wounds. Curli fimbriae is considered to be an important factor in the virulence of E.cloacae bacteria, which plays an important role in adhering and combining cells on solid surfaces to form the biofilmand helps in the adhesion
... Show MoreStructure of unstable 21,23,25,26F nuclei have been investigated
using Hartree – Fock (HF) and shell model calculations. The ground
state proton, neutron and matter density distributions, root mean
square (rms) radii and neutron skin thickness of these isotopes are
studied. Shell model calculations are performed using SDBA
interaction. In HF method the selected effective nuclear interactions,
namely the Skyrme parameterizations SLy4, Skeσ, SkBsk9 and
Skxs25 are used. Also, the elastic electron scattering form factors of
these isotopes are studied. The calculated form factors in HF
calculations show many diffraction minima in contrary to shell
model, which predicts less diffraction minima. The long tail
In this work lactone (1) was prepared from the reaction of p-nitro phenyl hydrazine with ethylacetoacetate, which upon treatment with benzoyl chloride afforded the lactame (2). The reaction of (2) with 2-amino phenol produced a new Schiff base (L) in good yield. Complexes of V(IV), Zr(IV), Rh(III), Pd(II), Cd(II) and Hg(II) with the new Schiff base (L) have been prepared. The compounds (1, 2) were characterized by FT-IR and UV spectroscopy, as well as characterizing ligand (L) by the same techniques with elemental analysis (C.H.N) and (1H-NMR). The prepared complexes were identified and their structural geometries were suggested by using elemental analysis (C.H.N), flame atomic absorption technique, FT-IR and UV-Vis spectroscopy, in additio
... Show MorePoly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys.
To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC).
A single-centre, two-arm parallel groups