Preferred Language
Articles
/
JhYwSIcBVTCNdQwCIkEn
Decentralized adaptive partitioned approximation control of high degrees-of-freedom robotic manipulators considering three actuator control modes
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Engineering
Experimental Investigating of Unsupported Excavation Considering Its Effect on a Nearby Axially Loaded Pile
...Show More Authors

An experimental model is used to simulate the loss of soil lateral confinement due to excavation nearby an individual axially loaded pile. The effects of various parameters, such as the horizontal distance of excavation, depth of excavation and pile slenderness ratios are investigated. The experimental analysis results showed the effect of excavation is more remarkable as the horizontal distance of excavation becomes closer to the pile than half pile length. The effect of excavation diminishes gradually as the horizontal distance increases beyond that distance for all the investigated pile slenderness ratios and depths of excavation. The pile head deflection, settlement and bending moments along pile increase with decreasing horizontal d

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 14 2018
Journal Name
International Journal Of Engineering & Technology
Hybrid DWT-DCT compression algorithm & a new flipping block with an adaptive RLE method for high medical image compression ratio
...Show More Authors

Huge number of medical images are generated and needs for more storage capacity and bandwidth for transferring over the networks. Hybrid DWT-DCT compression algorithm is applied to compress the medical images by exploiting the features of both techniques. Discrete Wavelet Transform (DWT) coding is applied to image YCbCr color model which decompose image bands into four subbands (LL, HL, LH and HH). The LL subband is transformed into low and high frequency components using Discrete Cosine Transform (DCT) to be quantize by scalar quantization that was applied on all image bands, the quantization parameters where reduced by half for the luminance band while it is the same for the chrominance bands to preserve the image quality, the zig

... Show More
View Publication
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Bulletin Of Mathematics And Statistics Research
New Approximation Operators Using Mixed Degree Systems
...Show More Authors

This paper is concerned with introducing and studying the first new approximation operators using mixed degree system and second new approximation operators using mixed degree system which are the core concept in this paper. In addition, the approximations of graphs using the operators first lower and first upper are accurate then the approximations obtained by using the operators second lower and second upper sincefirst accuracy less then second accuracy. For this reason, we study in detail the properties of second lower and second upper in this paper. Furthermore, we summarize the results for the properties of approximation operators second lower and second upper when the graph G is arbitrary, serial 1, serial 2, reflexive, symmetric, tra

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2012
Journal Name
International Journal Of Contemporary Mathematical Sciences
Approximation by Convex Polynomials in Weighted Spaces
...Show More Authors

Here, we found an estimation of best approximation of unbounded functions which satisfied weighted Lipschitz condition with respect to convex polynomial by means of weighted Totik-Ditzian modulus of continuity

Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Deflection Analysis of an Elastic Single Link Robotic Manipulator
...Show More Authors

Abstract

Robotics manipulators with structural flexibility provide an attractive alternative to rigid robotics manipulators for many of the new and evolving applications in robotics. In certain applications their use is unavoidable. The increased complexity in modeling and control of such manipulators is offset by desirable performance enhancements in some respects. In this paperthe single- link flexible robotics manipulator was designed and implemented from Perspex and designed with 0.5 m length , 0.02 m width and with 0.004 m thickness with mass located at the tip. There are four subsystems; motion, control, accelerometer and gyro and a host computer subsystem. The work principle of single-link robotics manipul

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Pharmaceutical Negative Results
The diagnostic value of Paraoxonase (PON 1) enzyme activity in the diagnosis of knee joint osteoarthritis: case control study
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Mon May 23 2022
Journal Name
The International Journal Of Artificial Organs
Quantitative analysis and control of the torque profile of the upper limb using a kinetic model and motion measurements
...Show More Authors

This paper investigates a new approach to the rapid control of an upper limb exoskeleton actuator. We used a mathematical model and motion measurements of a human arm to estimate joint torque as a means to control the exoskeleton’s actuator. The proposed arm model is based on a two-pendulum configuration and is used to obtain instantaneous joint torques which are then passed into control law to regulate the actuator torque. Nine subjects volunteered to take part in the experimental protocol, in which inertial measurement units (IMUs) and a digital goniometer were used to measure and estimate the torque profiles. To validate the control law, a Simscape model was developed to simulate the arm model and control law in which measurem

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Jun 30 2012
Journal Name
Al-kindy College Medical Journal
The Necessity of Teaching Diabetic Patients the Correct way of Insulin Administration: A Clinical Trial to Improve Glycemic Control
...Show More Authors

Background: It is important to achieve good glycemic control to avoid long-term diabetic complications. It has been largely debated about the role of correct way of insulin administration to get the desired glycemic control.
Objective: To evaluate the effect of teaching diabetic patients who are on insulin therapy the correct way of injecting insulin and its effect on glycemic control.
Methods: A non randomized clinical trial with 820 diabetic patients on insulin therapy on whom A1 c estimation was performed before and after three months of teaching them the right injection technique.
Results : Sixty seven patients (8.17%) had A1 c 6.5% before they were enrolled in the study while the majority (753 patents, 91.82%) had A1 c 6.5%

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 14 2023
Journal Name
Journal Of Educational And Psychological Researches
Comparative Study in Attitudes towards the Covid-19 Vaccine According to Locus of Control (Internal - External) of University Students
...Show More Authors

Abstract

The current research aims to identify the attitudes towards the Covid-19 vaccine and the Locus of Control (internal, external) among university students, to identify the significance of the difference in attitudes towards the Covid-19 vaccine, the significance of the difference in the Locus of Control (internal, external) according to the gender variable (male, female), and to identify the significance of the difference in students’ attitudes towards Covid-19 vaccine according to the Locus of Control (internal, external). To achieve the objective of the research, the researcher developed two scales, a scale of (20) items to identify the attitudes toward a covid-19 vaccine, and a scale of the locus of c

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Design and Implementation of an Automatic Control for Two Axis Tracking System for Applications of Concentrated Solar Thermal Power
...Show More Authors

The present work presents design and implementation of an automated two-axis solar tracking system using local materials with minimum cost, light weight and reliable structure. The tracking system consists of two parts, mechanical units (fixed and moving parts) and control units (four LDR sensors and Arduino UNO microcontroller to control two DC servomotors). The tracking system was fitted and assembled together with a parabolic trough solar concentrator (PTSC) system to move it according to information come from the sensors so as to keep the PTSC always perpendicular to sun rays. The experimental tests have been done on the PTSC system to investigate its thermal performance in two cases, with tracking system (case 1) and without trackin

... Show More
View Publication Preview PDF
Crossref (4)
Crossref