Introduction. Intraoperative rupture (IOR) of an aneurysm is a frightful complication that causes significant morbidity and mortality worldwide. IOR can be attributed to various parameters, including hypertension, increased intracranial pressure (ICP), fragility of the vessels, and inadequate anaesthesia. IOR due to insufficient anaesthesia is scarcely reported in the literature. Here, we describe a re-ruptured anterior communicating artery (ACoA) after incomplete clipping of the neck during craniotomy closure due to unintended early wake-up from anaesthesia with a discussion about the management. Case description. A 38-year-old male suddenly developed a severe headache, a brief loss of consciousness, and vomiting. Computed tomography (CT) scan showed a subarachnoid haemorrhage in the basal cistern. CT angiography showed a bilobed right ACoA aneurysm with a wide neck and Murphy's teat. The patient was considered for surgery. Clipping of the aneurysm neck was done through two curved clips. During craniotomy closure, the patient started coughing and gagging then a huge IOR was encountered. These events can be mainly attributed to unintended inadequate anaesthesia, particularly muscle relaxants. The bleeding ceased after two suction catheters were inserted, temporary clips were applied, and the readjustment of permanent clips. After surgery, the patient showed a left-sided weakness. His postoperative CT scan showed a right distal anterior cerebral artery (ACA) territory infarction. The weakness improved in the follow-up period. Conclusion. Delayed IOR due to early awaking from anaesthesia should be considered a potential source of complications and bad outcomes in aneurysm surgery.
Naturally occurring radioactive materials (NORM) contaminated sites at Al-Rumaila Iraqi oil fields have been characterized as a part of soil remediation project. Activity of radium isotopes in contaminated soil have been determined using gamma spectrometer High Purity Germanium detector (HPGe) and found to be very high for Al-Markezia, Al-Qurainat degassing stations and storage area at Khadhir Almay region. The activity concentration of samples ranges from 6474.11±563.8 Bq/kg to 1232.5±60.9 Bq/kg with mean value of 3853.3 Bq/kg for 226Ra, 843.59±8.39 Bq/kg to 302.2±9.2 Bq/kg with mean value of 572.9 Bq/kg for 232Th and 294.31±18.56 Bq/kg to 156.64±18.1 Bq/kg with mean value of 225.5 for 40K. S
... Show MoreIn this study, the acid-alkaline transesterification of refined coconut seed oil (RCOSO) to fatty acid methyl ester was followed by the production of a trimethylolpropane-based thermosensitive biolubricant using potassium hydroxide, and its physicochemical characteristics were evaluated. The American Standard Test for Materials (ASTM) was employed to ascertain the biolubricant's pour point and index of viscosity, which were found to be -4 oC and 283.75, respectively. The opposite connection between lubricant viscosity and temperature was shown by the measured viscosities at varied transesterification to be transformed into biodiesel. Following this, a biolubricant was created by further transesterifiedtemperature. The ester gr
... Show More<p>Analyzing X-rays and computed tomography-scan (CT scan) images using a convolutional neural network (CNN) method is a very interesting subject, especially after coronavirus disease 2019 (COVID-19) pandemic. In this paper, a study is made on 423 patients’ CT scan images from Al-Kadhimiya (Madenat Al Emammain Al Kadhmain) hospital in Baghdad, Iraq, to diagnose if they have COVID or not using CNN. The total data being tested has 15000 CT-scan images chosen in a specific way to give a correct diagnosis. The activation function used in this research is the wavelet function, which differs from CNN activation functions. The convolutional wavelet neural network (CWNN) model proposed in this paper is compared with regular convol
... Show MoreIn this research, the removal of cadmium (Cd) from simulated wastewater was investigated by using a fixed bed bio-electrochemical reactor. The effects of the main controlling factors on the performance of the removal process such as applied cell voltage, initial Cd concentration, pH of the catholyte, and the mesh number of the cathode were investigated. The results showed that the applied cell voltage had the main impact on the removal efficiency of cadmium where increasing the applied voltage led to higher removal efficiency. Meanwhile increasing the applied voltage was found to be given lower current efficiency and higher energy consumption. No significant effect of initial Cd concentration on the removal efficie
... Show MoreAspergillus fumigatus considered to be the most important species to cause respiratory infection cases in both humans and animals especially in cats in the last decades. In this study, we focused on the isolation and identification of Aspergillus fumigates by collecting 40 samples in deferent veterinary clinics and stray cats in Baghdad city, during the period (October 2021 to January 2022), all samples were cultured on Sabouraud dextrose agar and malt extract agar. The isolates identified by the laboratory methods, it’s depend on macroscopic and microscopic appearance. The results showed that (40) swaps taken from the pharynx of infected cats, included: Aspergillus fumigatus 16 (40%), Aspergillus spp. 7 (17.5%), Aspergillus niger
... Show MorePoly urea formaldehyde –Bentonite (PUF-Bentonite) composite was tested as new adsorbent
for removal of mefenamic acid (MA) from simulated wastewater in batch adsorption
procedure. Developed a method for preparing poly urea formaldehyde gel in basic media by
using condensation polymerization. Adsorption experiments were carried out as a function of
water pH, temperature, contact time, adsorbent dose and initial MA concentration .Effect of
sharing surface with other analgesic pharmaceuticals at different pH also studied. The
adsorption of MA was found to be strongly dependent to pH. The Freundlich isotherm model
showed a good fit to the equilibrium adsorption data. From Dubinin–Radushkevich model the
mean free
This study aims to show the effectiveness of immobilization of Chlorella green algae biomass in the form of bead for the removal of lead ions from synthetic polluted water at various operational parameters such as pH (2–6), biosorbent dosage (0.5–20 g/L) and initial concentration (10–100 mg/L). More than 90 % removal efficiency was achieved. FTIR and SEM-EDX analysis of the biosorbent before and after sorption show differences in the functional groups on the adsorbent surface. Langmuir and Freundlich equilibrium isotherm, pseudo-first-order and pseudo-second-order kinetic models were applied to the experimental and results and show good conformity with Langmuir isotherm model and pseudo-second-order kinetic model with c
... Show MoreThis work include synthesized and characterization the compound [I] by reaction 1,4-phenylenediamine with chloro acetic acid then this compound reaction with methanol in present sulfuric acid to synthesized ester compound [II] after that reaction with hydrazine hydrate to synthesized acide hydrazide [III] and the later compound reaction with substituted acetophenone[IV]n to synthesized substituted acetophenone hydrazones[V-XI]. In addition synthesized4-formylpyrazole derivatives [XIIXVIII] via cyclisation substituted acetophenone hydrazones [V-XI] with Vilsmeier-Haack reagent DMF/POCl3. The compounds characterized by melting points, FTIR, 1HNMR and mass spectroscopy. The mesomorphic behavior studied by using polarized optical microscopy and
... Show MoreBiosorption is an effective method to remove toxic metals from wastewaters. In this study biosorption of lead and chromium ions from solution was studied using Citrobacter freundii and Citrobacter kosari isolated from industrial wastewater. The experimental results showed that optimum grwoth temperature for both bacteria is 30oC and the optimum pH is 7 &6 for C. freundii and C. kosari respectively. While the optimum incubation period to remove Pb and Cr for C. freundii and C. kosari is 4 days and 3days respectively. Also the biosorption of Pb and Cr in mixed culture of bacteria and mixed culture of Pb and Cr was investigated. Result indicate that uptake of Cr and Pb for C.freundii, C. kosari and in mixes culture of both bacteria is 58%, 53%
... Show More