Abstract: This study aims to investigate the backscattering electron coefficient for SixGe1-x/Si heterostructure sample as a function of primary electron beam energy (0.25-20 keV) and Ge concentration in the alloy. The results obtained have several characteristics that are as follows: the first one is that the intensity of the backscattered signal above the alloy is mainly related to the average atomic number of the SixGe1-x alloy. The second feature is that the backscattering electron coefficient line scan shows a constant value above each layer at low primary electron energies below 5 keV. However, at 5 keV and above, a peak and a dip appeared on the line scan above Si-Ge alloy and Si, respectively, close to the interfacing line. Furthermore, the shape and height of peak and dip broadening depend on the primary electron energy and incidence position with respect to the interfacing line. The last feature is that the spatial resolution of the backscattered signal at the interfacing line is improving by decreasing the primary electron energy (below 5 keV) and the shared element (Si) concentration. On the other hand, a poor compositional contrast has been shown at low primary electron energy below 5 keV. For energies above 5 keV, the spatial resolution becomes weak. These results can be explained by the behavior of the incident electrons inside the solid (interaction volume), especially at a distance close to the interfacing line and their chance to backscatter out of the sample. In general, a good compositional contrast with a high spatial resolution can be achieved at primary electron energy equal to 1 keV. Keywords: Monte Carlo model, Backscattering electron coefficient, Si-Ge/Si, Elastic scattering, Spatial resolution, Compositional contrast.
In this work, an explicit formula for a class of Bi-Bazilevic univalent functions involving differential operator is given, as well as the determination of upper bounds for the general Taylor-Maclaurin coefficient of a functions belong to this class, are established Faber polynomials are used as a coordinated system to study the geometry of the manifold of coefficients for these functions. Also determining bounds for the first two coefficients of such functions.
In certain cases, our initial estimates improve some of the coefficient bounds and link them to earlier thoughtful results that are published earlier.
Objective: The aim of this study was to assess the knowledge and attitude of Iraqi dentists towards cone beam computed tomography (CBCT) applications in endodontics by using an online survey. Materials and Methods: A questionnaire, consisting of 31 questions, targeted general dental practitioners and specialists in different dental specialities. A total of 306 participants were included. Data were assessed according to the frequency of distribution and the chi-square test was applied to analyse the difference in responses between two independent groups. Results: Among the participants 63.4% were using digital radiography in their daily practice, and 84% had awareness about CBCT's uses, with higher statistically significant responses among e
... Show MoreThis study discussed a biased estimator of the Negative Binomial Regression model known as (Liu Estimator), This estimate was used to reduce variance and overcome the problem Multicollinearity between explanatory variables, Some estimates were used such as Ridge Regression and Maximum Likelihood Estimators, This research aims at the theoretical comparisons between the new estimator (Liu Estimator) and the estimators
Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician cou
... Show MoreObjectives To compare the clinical efficacy of microvascular decompression surgery (MVD) and gamma knife radiosurgery (GKR) as a treatment for patients with primary trigeminal neuralgia (TN) and evaluate the outcome regarding pain relief, recurrence, and complications with both modalities of treatment. Patients and Methods A randomized prospective study conducted in SaadAlwitry Neurosciences Hospital, Baghdad, Iraq. Eighty-four patients with TN from January 2016 to January 2018, 45 patients had GKR while 39 patients treated with MVD. The pain evaluated pre-and post-operatively using the Barrow Neurological Institute Pain Intensity scale (BNIPI), visual analog scale (VAS) and Brief Pain Inventory Facial (BPI-Facial) scoring systems. In GKR p
... Show MoreInternal conversion coefficients (ICC) and electron–positron pair conversion coefficients (PCC) for multipole transition of the core nucleus 88Sr have been calculated theoretically. The calculation is based on the relativistic Dirac–Fock (DF) solutions using the so called ‘‘Frozen Orbital’’ approximation, takes into account the effect of atomic vacancies created in the conversion process, covering a transition energies of 1–5000 keV. A large number of points were used to minimize any errors due to mesh-size effects. The internal conversion coefficients display a smooth monotonic dependence on transition energy, multipolarity and atomic shell. Comparing the values of PCC to ICC, it is interesting to note, that the energy dep
... Show MoreThe flow in a manifolds considered as an advanced problem in hydraulic engineering applications. The objectives of this study are to determine; the uniformity qn/q1 (ratio of the discharge at last outlet, qn to the discharge at first outlet, q1) and total head losses of the flow along straight and rectangular loop manifolds with different flow conditions. The straight pipes were with 18 m and 19 m long and with of 25.4 mm (1.0 in) in diameter each. While, the rectangular close loop configuration was with length of 19 m and with diameter of 25.4 mm (1.0 in) also. Constant head in the supply tank was used and the head is 2.10 m. It is found that outlets spacing and manifold configuration are the main factors aff
... Show MoreLacing reinforcement plays a critical role in the design and performance of reinforced concrete (RC) slabs by distributing the applied loads more evenly across the slab, ensuring that no specific area of the slab is overloaded. In this study, nine slabs, divided into three groups according to the investigated parameters, were meticulously designed and evaluated to study the interplay between the lacing reinforcement and other key parameters. Each slab was crafted for simple support and was subjected to both static and repeated two-point load tests. The lacing reinforcement had an angle of 45° with various tension and lacing steel. The repeated-tested specimens with lacing reinforcement experienced smaller ductility than those of s
... Show MoreGeomechanical modelling and simulation are introduced to accurately determine the combined effects of hydrocarbon production and changes in rock properties due to geomechanical effects. The reservoir geomechanical model is concerned with stress-related issues and rock failure in compression, shear, and tension induced by reservoir pore pressure changes due to reservoir depletion. In this paper, a rock mechanical model is constructed in geomechanical mode, and reservoir geomechanics simulations are run for a carbonate gas reservoir. The study begins with assessment of the data, construction of 1D rock mechanical models along the well trajectory, the generation of a 3D mechanical earth model, and runni
Lacing reinforcement plays a critical role in the design and performance of reinforced concrete (RC) slabs by distributing the applied loads more evenly across the slab, ensuring that no specific area of the slab is overloaded. In this study, nine slabs, divided into three groups according to the investigated parameters, were meticulously designed and evaluated to study the interplay between the lacing reinforcement and other key parameters. Each slab was crafted for simple support and was subjected to both static and repeated two-point load tests. The lacing reinforcement had an angle of 45° with various tension and lacing steel. The repeated-tested specimens with lacing reinforcement experienced smaller ductility than those of s
... Show More