Abstract: This study aims to investigate the backscattering electron coefficient for SixGe1-x/Si heterostructure sample as a function of primary electron beam energy (0.25-20 keV) and Ge concentration in the alloy. The results obtained have several characteristics that are as follows: the first one is that the intensity of the backscattered signal above the alloy is mainly related to the average atomic number of the SixGe1-x alloy. The second feature is that the backscattering electron coefficient line scan shows a constant value above each layer at low primary electron energies below 5 keV. However, at 5 keV and above, a peak and a dip appeared on the line scan above Si-Ge alloy and Si, respectively, close to the interfacing line. Furthermore, the shape and height of peak and dip broadening depend on the primary electron energy and incidence position with respect to the interfacing line. The last feature is that the spatial resolution of the backscattered signal at the interfacing line is improving by decreasing the primary electron energy (below 5 keV) and the shared element (Si) concentration. On the other hand, a poor compositional contrast has been shown at low primary electron energy below 5 keV. For energies above 5 keV, the spatial resolution becomes weak. These results can be explained by the behavior of the incident electrons inside the solid (interaction volume), especially at a distance close to the interfacing line and their chance to backscatter out of the sample. In general, a good compositional contrast with a high spatial resolution can be achieved at primary electron energy equal to 1 keV. Keywords: Monte Carlo model, Backscattering electron coefficient, Si-Ge/Si, Elastic scattering, Spatial resolution, Compositional contrast.
Background: Osteoarthritis (OA) is a degenerative joint disease. It is one of the major causes of disability in developed and developing countries. Human leukocyte antigen (HLA) as part of immune system has a role in the disease process.Objectives: To investigate whether there is an association between HLA class II-DRB and OA.Methods: A case control study with 26 patients with osteoarthritis and 22 apparently healthy obese control persons matching in ethnicity were enrolled in this study during the period between October 2012 till March 2013. Direct interview was done with each patient and HLA typing was done by molecular method using Sequence Specific Primer (PCR-SSP) method using One Lambda Kit-USA. Results: The results showed that fem
... Show MorePhotodetector based on Rutile and Anatase TiO2 nanostructures/n-Si Heterojunction
The aim of this research is to diagnose the attention deficit hyperactivity disorder among primary school pupils in Baquba city of Diyala province. The sample of the study consisted of (25) male and female pupils. The American Guide of Attention Deficit Hyperactivity Scale (DSM-IV, 1994) was used in this study in addition to Conner’s (1996) scale to measure the attention deficit hyperactivity disorder for teachers and parents. The result revealed that (19) male and female pupils diagnosed with attention deficit hyperactivity to various degrees.
The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser
The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser
Levels of primary education are varying in Sulaimaniyah Province, which defines as a lower stage of education process and seems to be found in most settlements to save the individual and community from illiteracy in its traditional notion which means the individuals, potentiality for reading and writing if he/she graduated from this stage successfully. The research can put the priority for goodness of primary education service within Sulaimaniyah Province that includes Sulaimaniyah city as a dominance based on statistical indicator which called the standardized score (z). The indicator (z) calculated for the basic items of primary education to diagnosis the range of developing that service in Sulaimaniyah city especially and put
... Show MoreBackground: Insulin resistance is present in 50% or more of patients with primary hypothyroidism. Metformin can decrease TSH levels in these patients by a complex matter, this can be of great help in clinical practice.
Objective: This study was designed to evaluate the effect of metformin in reducing TSH levels in patients with primary hypothyroidism.
Methods: Hundred patients with primary hypothyroidism, 82 females, 18 males were included in this study, everyone was followed up for two months after adding metformin 850 mg twice daily in addition to thyroxin.
Results: 36 patients (36%) have a normal baseline TSH and no change after 2 months, 64 pa
... Show MoreAn effort is made to study the effect of composite nanocoating using aluminum-9%wt silicon alloys reinforced with different percentage (0.5,1,2,4)wt.% of carbon nanotubes (CNTs) using plasma spraying. The effect of this composite on corrosion behavior for AA6061-T6 by extrapolation Tafel test in sea water 3.5wt% NaCl was invested. Many specimens where prepared from AA6061-T6 by the dimension (15x15x3)mm as this first set up and other steps include coating process, X-ray diffraction and SEM examination .The results show the CNTs increase the corrosion rate of the nanocomposite coatings with increasing the weight percentage of CNTs within the Al-Si matrix. Al-9wt%Si coating layer itself has less corrosion rate if compared with both n
... Show MoreWe investigated at the optical properties, structural makeup, and morphology of thin films of cadmium telluride (CdTe) with a thickness of 150 nm produced by thermal evaporation over glass. The X-ray diffraction study showed that the films had a crystalline composition, a cubic structure, and a preference for grain formation along the (111) crystallographic direction. The outcomes of the inquiry were used to determine these traits. With the use of thin films of CdTe that were doped with Ag at a concentration of 0.5%, the crystallization orientations of pure CdTe (23.58, 39.02, and 46.22) and CdTe:Ag were both determined by X-ray diffraction. orientations (23.72, 39.21, 46.40) For samples that were pure and those that were doped with
... Show More