Pesticide poisoning is a serious global public health issue and is responsible for a sizable number of annual fatalities. This study was designed to examine the potentially harmful effects of adult rats being exposed to imidacloprid (IMD) as a nanoparticle by determining the chronic effect of inhalation of (5,10 and 20) mg/kg/b.w. of nano-imidacloprid for a duration of 60 days. The most important biochemical parameters of the serum liver function parameters were aspartate aminotransferase (AST), alanine aminotransferase (ALT), and alkaline phosphatase ALP, kidney function [blood urea, creatinine, and urea], and oxidative stress parameters (MDA, GSH, and CAT) in all treated groups when compared to the control group. The exposure caused a highly significant decrease (P≤0.05) for (AST) and (ALT). No significant changes were observed, while a highly significant decrease was recorded for (ALP) in all treatments with nano-imidacloprid compared with the control. On the other hand, a highly significant decrease in blood urea, creatinine, and uric acid was recorded in all groups treated with nano-imidacloprid compared with the control. Oxidative stress parameters revealed a highly significant (P≤0.05) increase in malondialdehyde (MDA) after 60 days of exposure and a decline in reduced glutathione (GSH) and catalase activity CAT.
KE Sharquie, SA Al-Mashhadani, AA Noaimi, MY Abbas, Journal of the Saudi Society of Dermatology & Dermatologic Surgery, 2011 - Cited by 5
Back ground; Selective re-absorption and secretion are the functions of the collecting tubules and ducts, in addition to concentrate urine through ADH-regulated and ADH-independent water channels.Method; twenty four male rats were used, they were divided into two groups of animals: Group (A) included twelve rats of five weeks old age (before puberty) that were divided into three subgroups, four rats in each subgroup. Subgroup I was control one, subgroups II and III were treated orally with melatonin in a dose of 250 & 500 µg/kg body weights subsequently. Group (B) included twelve rats of seventeen weeks old age (after puberty) that were divided into the same subgroups and treated with the doses of melatonin as in the rats of group (
... Show MoreBackground: Polymethyl methacrylate (PMMA) is used in denture fabrication and considered as the most reliable material for the construction of removable prosthodontic appliances. The material is far from ideal in fulfilling the mechanical requirements and the effect of autoclave processing has not been fully determined. The purpose of this study was to evaluate the effect of addition of salinized (ZrO2) Nano fillers in percentages 3%, 5% and 7% by weight on some properties of heat cured acrylic processed the by autoclave and compare it with 0% (control) group . Materials and methods: The silanized(ZrO2) Nano-particles was added to PMMA powder by weight in three different percentages 3%, 5% and 7%, mixed by probe ultra-sonication machine.
... Show MoreBackground: Polymethyl methacrylate (PMMA) is the most commonly used material in denture fabrication. The material is far from ideal in fulfilling the mechanical requirement. The purpose of this study was to evaluate the effect of addition of 3% wt of treated (silanized) Titanium oxide Nano filler on some physical and mechanical properties of heat cured acrylic denture base material. Materials and methods: 100 specimens were constructed, 50 specimens were prepared from heat cure PMMA without additives (control) and 50 specimens were prepared from heat cure PMMA with the addition of TiO2 Nano fillers. Each group was divided into 5 sub groups according to the test performed which was mixed by probe ultra-sonication machine. Results: A highly
... Show MoreThe specifications of lubricating oil are fundamentally the final product of materials that have been added for producing the desired properties. In this research, spherical nanoparticles copper oxide (CuO) and titanium oxides (TiO2) are added to SAE 15W40 engine oil to study the thermal conductivity, stability, viscosity of nano-lubricants, which are prepared at different concentrations of 0.1%, 0.2%, 0.5%, and 1% by weight, and also their pour point, and flash point as five quality parameters. The obtained results show that CuO nanoparticles in all cases, give the best functionality and effect on engine oil with respect to TiO2. With 0.1 wt. % concentration, the thermal conductivity of CuO/oil and TiO2/
... Show MoreThe purpose of this study was to examine the histological structure of the kidney in snake Eryx gaculus gaculus. In present study, the snakes were collected from the city of Baghdad and transferred to the laboratory where their kidneys were dissected out. The samples were then processed to be prepared for histological examination microscopial observations showed that there is no border between the cortex and medulla regions of kidney. The kidney consists of nephrons which are composed of glomerulus surrounded by Bowman’s capsule; the other segments are proximal tubule, distal tubule and connecting tubule. The epithelial tissue lining of these segments simple cuboidal tissue.
Self-compacting concrete (SCC) has undergone a remarkable evolution recently based on the results from several studies that have indicated the chain of benefits SCC provides. Micro and nano materials used as mineral additives in SCC offer several high-performance properties, and this research studies the effects of micro silica (MS) (10%, used as a reference) and colloidal nano-silica (CNS) (2.5%, 5%, 7.5%, and 10%) on the fresh and hardened properties of SCC. All mixtures were estimated using flow, L-box, and V-funnel tests to examine workability and compressive strength, modulus of elasticity and tensile strength as hardened properties. The use of CNS increased the overall compressi
Background: Even the wide use of dental implants, still there is a proportion of implants are failed due to infection. Much considerable attention has been paid to modify the implant surface. Coating of dental implant with a biocomposite material of suitable properties can improve osseointegration. And this is the main concern of this study. The aim of present study was to evaluate the use of a biocomposite coating of dental implant with (ceramic nano Al2O3 and metalic AgNo3) on the bond strength at bone – implant interface and tissue reaction. Materials and methods: A total number of forty-eight screws, CpTi dental implant used in this study. Half of these screws were coated with a biocomposite material of nano (Al2O3and AgNo3), thi
... Show More