The angiotensin converting enzyme (ACE) I\D gene polymorphism influences the blood ACE enzyme activity. Renoprotective effect of ACE inhibitors (ACEIs) varies among patients due to genetic variation, particularly in Renin-Angiotensin-Aldosterone System genes. This study investigates the genetic variations of ACE I\D and AGT1RA1166C gene polymorphisms in the antiproteinuric effect of ACEI therapy in type 2 diabetes mellitus (T2DM) patients. This is a cross-sectional study that included 76 T2DM patients who are ACEI users, divided into two groups: T2DM without diabetic kidney disease (DKD) included 31 patients, and T2DM with DKD included 45 patients. Urine samples were taken for measurement of urine albumin and creatinine, then calculation of albumin-creatinine ratio (ACR). Blood samples were taken for the measurement of serum parameters and also for the extraction of DNA for genetic evaluation of ACEI/D and AGT1RA1166C gene polymorphisms. The results reveal that T2DM patients carrying the ID genotype have significantly lower ACE1 levels compared to DD and II carriers (p = 0.012). When grouping patients according to the ACR, serum ACE1 and angiotensin-converting enzyme 2 (ACE2) levels were higher in DKD compared to normalbuminuric patients, with the only significant difference for ACE2. After subdividing according to ACE I\D genotypes, the ACE2 differences were only significant in DD genotype carriers (p = 0.049) between DKD and normalbuminuric groups. While for AGT1RA1166C polymorphisms, the AC genotype shows non-significantly lower levels for ACE1 and ACE2. After subdividing according to AGT1RA1166C genotypes, ACE2 levels were significantly higher in DKD patients carrying the AA genotype (p = 0.015). Binary logistic regression analysis revealed that both ACE (I\D) and AGT1RA1166C genes are significant predictors of ACE1 levels after controlling age, gender, and DKD state. This study concluded that both genes are predictors of ACE1 levels; in addition, ID genotype carriers and AC genotype carriers had lower ACE1 and ACE2 levels with lower ACR and higher glomerular filtration rate, identifying better ACEIs responses in ID and AC carriers.
Background: Radiotherapy, is therapy using ionizing radiation in order to deliver an optimal dose of either particulate or electromagnetic radiation to a particular area of the body with minimal damage to normal tissues. The source of radiation may be outside the body of the patient (external beam irradiation) or it may be an isotope that has been implanted or instilled into abnormal tissue or a body cavity. Called also radiotherapy. The aim of work studies the relationship between the depth dose and the high photon xray energies (6MeV and 10MeV). Patients and methods: in our work, we studied the dose distribution in water phantom given at different depths (zero-18) cm deep at1cm intervals treated with different field size (5×5-,10×1
... Show MoreIn this study, the thermal buckling behavior of composite laminate plates cross-ply and angle-ply all edged simply supported subjected to a uniform temperature field is investigated, using a simple trigonometric shear deformation theory. Four unknown variables are involved in the theory, and satisfied the zero traction boundary condition on the surface without using shear correction factors, Hamilton's principle is used to derive equations of motion depending on a Simple Four Variable Plate Theory for cross-ply and angle-ply, and then solved through Navier's double trigonometric sequence, to obtain critical buckling temperature for laminated composite plates. Effect of changing some design parameters such as, ortho
... Show MoreA new simple, sensitive and inexpensive method has been developed for the spectrophotometric determination of cisapride in pharmaceutical formulation. The turbidimetric method is based on the formation of the ion-pair complex between the drug and bromophenol blue (BPB) in presence of potassium chloride at pH= 2.6, with a maximum absorbance at 520 nm. The calibration graph is linear in the concentration range 5-50µg.ml-1 , with good correlation coefficient (r = 0.9989).The limit of detection was found to be 1.14 µg.ml-1 and no interference was observed from common excipients in the pharmaceutical preparation that contain cisapride with good accuracy and precision.
In this manuscript has investigated the synthesis of plasma-polymerized pyrrole (C4H5N) nano-particles prepared by the proposed atmospheric pressure nonequilibrium plasma jet through the parametric studies, particularly gas flow rate (0.5, 1 and 1.5 L/min). The plasma jet which used operates with alternating voltage 7.5kv and frequency 28kHz. The plasma-flow characteristics were investigated based on optical emission spectroscopy (OES). UV-Vis spectroscopy was used to characterize the oxidization state for polypyrrole. The major absorption appears around 464.1, 449.7 and 435.3 nm at the three flow rate of argon gas. The chemical composition and structural properties of the
... Show MoreIn this work, nanostructure aluminum oxide thin films were deposited on glass substrates using a direct current (DC) magnetic reactive sputtering (MRS) technique. A gaseous mixture of argon and oxygen at different mixing ratios was used to synthesize Al2O3 nanoparticles. After extracting Al2O3 powder from the glass substrate, X-ray diffraction (XRD), field-emission scanning electron microscopy (FE-SEM), and energy-dispersive spectroscopy (EDS) were used to analyze the structural and morphological properties of the synthesized thin films. The effect of deposition time on the spectral properties, as well as on the size of the nanoparticles, was determined.