In the recent decade, injection of nanoparticles (NPs) into underground formation as liquid nanodispersions has been suggested as a smart alternative for conventional methods in tertiary oil recovery projects from mature oil reservoirs. Such reservoirs, however, are strong candidates for carbon geo-sequestration (CGS) projects, and the presence of nanoparticles (NPs) after nanofluid-flooding can add more complexity to carbon geo-storage projects. Despite studies investigating CO2 injection and nanofluid-flooding for EOR projects, no information was reported about the potential synergistic effects of CO2 and NPs on enhanced oil recovery (EOR) and CGS concerning the interfacial tension (γ) of CO2-oil system. This study thus extensively investigates the effect of silica NPs on the γ of CO2/decane system at elevated pressure and temperature to recognise the potential impact of NPs-injection on the future CGS projects. To achieve this, a wide-ranging series of tests have been conducted to reveal the role of hydrophilic and hydrophobic silica NPs on γ of the CO2/oil system. n-decane was utilized as model oil and different amounts of NPs were mixed with the oil phase. Oil-NPs dispersions were formulated using an ultrasonic homogenizer. The γ of the CO2/oil system was measured at different pressures (0.1 to 20 MPa) and temperatures (25 to 70 °C) using a high-pressure temperature optical cell. The γ data were measured using the pendant drop technique via axisymmetric drop shape analysis (ADSA). The results showed that, generally, CO2/oil γ subjected mainly to pressure, temperature, and with less extent to NPs load in the oil phase. γ decreases with increased pressure until reaching a plateau where no more significant decrease in γ was observed. The γ trend with increased temperature, on the other hand, was more completed. No significant impact of temperature on γ was recorded with low pressure (≤ 5 MPa). Similarly, at relatively high pressure (≥ 25 MPa), only a slight variation of IFT with temperature change was recorded. However, for the pressure range from 5 – 25 MPa, IFT was increased remarkably with temperature. Furthermore, NPs in the oil phase exhibit a remarkable influence on IFT. In this context, the presence of hydrophilic silica NPs in the oil phase can significantly reduce the γ of the CO2/decane system. However, hydrophobic silica NPs showed less influence on IFT reduction. The outcomes of this work afford good understandings into applications of NP for EOR and CGS applications and help to de-risk CO2-geological storage projects.
Empirical and statistical methodologies have been established to acquire accurate permeability identification and reservoir characterization, based on the rock type and reservoir performance. The identification of rock facies is usually done by either using core analysis to visually interpret lithofacies or indirectly based on well-log data. The use of well-log data for traditional facies prediction is characterized by uncertainties and can be time-consuming, particularly when working with large datasets. Thus, Machine Learning can be used to predict patterns more efficiently when applied to large data. Taking into account the electrofacies distribution, this work was conducted to predict permeability for the four wells, FH1, FH2, F
... Show MoreThe corrosion behavior of low carbon steel in washing water of crude oil solution has been studied potentiostatically at five temperatures in the range ( 303 –343 )K, at pH ( 4 ) and at pH (4,6,7,9,11 ) at (343K)..The corrosion potential shifted to more negative values with increasing temperature and the corrosion current density increased with increasing temperature, the corrosion current density (icorr) decreased with increasing pH in the rang ( 4 – 7 ) and it increased with increasing pH in the rang ( 9 – 11 ) at ( 343 K ), while the corrosion potential generally variation with increasing pH in the rang (4-11)at(343K. From the general results for this study can be seen that thermodynamic and kinetic function were
... Show MoreIn this study, a mathematical model is presented to study the chemisorption of two interacting atoms on solid surface in the presence of laser field. Our mathematical model is based on the occupation numbers formula that depends on the laser field which we derived according to Anderson model for single atom adsorbed on solid surface. Occupation numbers formula and chemisorption energy formula are derived for two interacting atoms (as a diatomic molecule) as they approach to the surface taking into account the correlation effects on each atom and between atoms. This model is characterized by obvious dependence of all relations on the system variables and the laser field characteristics which gives precise description for the molecule –
... Show MoreUmbilical cord blood (UCB) contains hematopoietic and mesenchymal stem cells(HSCs,MSCs) that have proven useful clinically to reconstitute the hematopoietic system in children and some adults . Fifteen cord blood samples were collected from placenta of newly delivered women in AlKadhemia hospital in Baghdad for normal vaginal delivery. Mono nucleated cells (MNCs) were isolated by using density gradient centrifugation and the MNCs count and viability were determinated by trypan blue.MNCs were cryopreserved using the cryoprotectant solution of 10% concentration of dimethyl sulfoxid (DMSO)using slow cooling and rapid thaw. The aim of the present study
... Show MoreExperimental tests were conducted to investigate the thermal performance (cooling effect) of water mist system consisting of 5μm volume median diameter droplets in reducing the heat gain entering a room through the roof and the west wall by reducing the outside surface temperature due to the evaporative cooling effect during the hot dry summer of Baghdad/Iraq. The test period
was Fifty one days during the months May, June, and July 2012. The single test day consists of 16 test hours starting from 8:00 am to 12:00 pm. The results showed a reduction range of 1.71 to 15.5℃ of the roof outside surface temperature and 21.3 to 76.6% reduction in the daily heat flux entering the room through the roof compared with the case of not using w
Biaxial hollow slab is a reinforced concrete slab system with a grid of internal spherical voids included to reduce the self-weight. This paper presents an experimental study of behavior of one-way prestressed concrete bubbled slabs. Twelve full-scale one-way concrete slabs of (3000mm) length with rectangular cross-sectional area of (460mm) width and (150mm) depth. Different parameters like type of specimen (solid or bubbled slabs), type of reinforcement (normal or prestress), range of PPR and diameter of plastic spheres (100 or 120mm) are considered. Due to the using of prestressing force in bubbled slabs (with ratio of plastic sphere diameter D to slab thickness H, D/H=0.67), the specimens showed an increase in ultimat
... Show MoreThis study aimed to determine histological and functional effects of Galangin (Gal) conjugated with Gold nanoparticles (AuNPs) on the Kidneys male albino mice treated with CCL4. Gold nanoparticles were prepared chemically by Turkevich Method. Characterizing of the prepared AuNPs and AuNPs+Gal was carried out using UV Spectrophotometry, X-Ray Diffraction (XRD) and particle size,. For the in vivo study, 42 adult male albino mice were used and randomly distributed into seven groups and experiment extended for 14 days, first group (G1) was control group without any treatment, (G2) group injected intra-peritoneal (i.p) with CCl4 once a week to the end of experiments, (G3) injected with AuNPs, (G4 and
... Show MoreIn this paper, we studied the spark corona discharge in tap and distillited waters. The results show the shape of cone that generated on the tip of capillary tube is different with conductivity of liquids. The blue glow appears at the end of capillary tube and the drop extends into a cone. In addition, the conducitivity is affected on the relationship between the appearance of the blue glow discharge with the applied voltage. The size of the cone decreases with an increase in applied voltage. The cone diameter at the base of capillary tube oscillates with period approximately 1 Sec. this oscillates in the cone diameters is due to the change distance between the liquid electrode and the surface of liquid. The intensity of spark corona dis
... Show More