Preferred Language
Articles
/
HRczhJABVTCNdQwCTIzT
Spectrophotometric determination of ciprofloxacin by Ion pair complex formation with bromothymol blue‏
...Show More Authors

Publication Date
Sat Jun 21 2025
Journal Name
Journal Of University Of Anbar For Pure Science
Semi – automated analysis for the Nanoscale determination of Chlorpheniramine maleate drug using sodium nitroprusside by continuous flow feed via homemade NAG-SSP Photometer
...Show More Authors

This study presents a rapid, sensitive, and straightforward approach to measure chlorpheniramine maleate (CPM) by using turbidity CFIA. The method involves CPM reacting with sodium nitroprusside (Nitropress) to produce a pale white precipitate. The NAG-SSP-5S1D analyzer was used to measure turbidity at 0°–180° angle to detect the attenuation of incident light as a result of collision on the surfaces of the precipitate particles. The linear range of CPM measurements was between 0.008 and 11 m.mol/L, with correlation coefficient of 0.9983 and R2% = 99.65. The limit of detection was determined to be 0.0328 µg/sample from the lowest concentration in the calibration curve, and the repeatability of the method (RSD%) was less than 0.4% (n = 6

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Wed Apr 01 2020
Journal Name
Isa Transactions
Design of a Complex fractional Order PID controller for a First Order Plus Time Delay system
...Show More Authors

View Publication
Scopus (51)
Crossref (43)
Scopus Clarivate Crossref
Publication Date
Wed Oct 26 2022
Journal Name
Aims Geosciences
Calculation and determination of radioactivity in the old district of Najaf by using the track detector CR-39 and geographical information systems (GIS) methods
...Show More Authors

This research aims to study the radiation concentration distribution of the old District of Najaf (Iraq), where 15 samples were taken from featured sites in the District, which represents archaeological, religious, and heritage sites. Track detector CR-39 was used to calculate the concentration of three different soil weights for each sample site after being exposed for a month. Geographical information systems (GIS) were used to distribute the radioactive concentration on the sites of the samples, where two interpolation methods, namely the inverse distance weight method (IDW) and the triangle irregular network method (NIT), to study the distribution of the radioactivity concentration. The study showed that the western part of the district

... Show More
View Publication Preview PDF
Crossref (2)
Clarivate Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Digital Signal Processing
Reverberant signal separation using optimized complex sparse nonnegative tensor deconvolution on spectral covariance matrix
...Show More Authors

View Publication
Scopus (9)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Mon May 11 2020
Journal Name
Baghdad Science Journal
On the Growth of Solutions of Second Order Linear Complex Differential Equations whose Coefficients Satisfy Certain Conditions
...Show More Authors

In this paper, we study the growth of solutions of the second order linear complex differential equations  insuring that any nontrivial solutions are of infinite order. It is assumed that the coefficients satisfy the extremal condition for Yang’s inequality and the extremal condition for Denjoy’s conjecture. The other condition is that one of the coefficients itself is a solution of the differential equation .

View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sun Nov 04 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Determination of Quality of Life for Adult Patients
...Show More Authors

Objective: The study aimed to determine quality of life domains for adult patients with limbs loss and to identify
the association between quality of life domains and demographic characteristics and medical information.
Methodology: A descriptive study was carried out at Baghdad artificial limb center, Al-Salam medical
rehabilitation center, Al-Ghadeer medical rehabilitation center and the rheumatoid and medical rehabilitation
center for the period from September 2007 to April 2008. A purposive ''non- probability'' sample of (200)
patients with limbs loss. Questionnaire form was constructed for the purpose of the study. Data were collected
through the application of the questionnaire and interview technique. Data were a

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 04 2011
Journal Name
Baghdad Science Journal
Determination of bacterial contamination of milk using fluorometry
...Show More Authors

The aim of this paper is to determine the feasibility of using fluorometric methods as an indicator for quality and contamination of milk with E.coli bacteria, and selection the suitable wavelength to be used with laser induced auto fluorescence. Three groups of milk samples were used in this study: Fresh pasteurized milk samples, milk samples containing different concentration of E.coli bacteria which were added artificially, and milk samples that were kept in refrigerator for 3-5 days. Thirteen excitation wavelengths were used to get the emission spectra for all milk samples using spectroflourometer .The results showed that the emission spectra at 275nm excitation wavelength gave a good differentiation between these three groups.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 25 2020
Journal Name
International Journal Of Drug Delivery Technology
Development of a Simple Colorimetric Determination of Dexamethasone
...Show More Authors

A simple, environmentally benign, cost-effective, and sensitive colorimetric determination for the pharmaceutical drug dexamethasone sodium phosphate (DXP) has been developed by the formation of a colored complex with fluoranil. The process was sensitive and linear over the range 1 to 40 μg/mL, excellent correlation coefficient 0.9989, recovery% 99.80 ± 1.3, limit of detection (LOD) and limit of quantification (LOQ) were 0.23 and 0.9 μg/mL, respectively, and good RSD ~1.63%. The experimental conditions were optimized after an intensive study. The approach was validated statistically for the quantification of the analyte in its pure and/or pharmaceutical form. Despite the proposed approach is selective, it still can be applied for

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Mon Feb 23 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of dental implant stability during healing period and determination of the factors that affect implant stability by means of resonance frequency analysis(Clinical study)
...Show More Authors

Background: Implant stability is considered one of the most important factors affecting healing and successful osseointegration of dental implants. The aims of the study were to measure the implant stability quotient (ISQ) values during the healing period and to determine the factors that affect implant stability. Materials and methods: Thirty patients enrolled in the study (17 female, 13 male). They received 44 Implantium® Dental Implants located as the following: 22 implants in maxillary jaw, 22 implants in mandibular jaw from them 17 implants in anterior segment and 27 in posterior segment. The bone density determined using interactive CT scan and classified according to the Misch bone density classification (29 implants in (D3), 15 i

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Computational And Theoretical Nanoscience
Controlling of Robot Hand by Using Microcontroller with Visual Basic
...Show More Authors

The robot arm is the most popular robotic form used in industry. Thus, it is crucial to make a system programming which could controlled the movement of each part in the industrial robot to make it works properly. One of the simplest models of the robot arm is EDARM ED-7100 which has a controller to control the movement of the robot arm manually. In this study, the robot controller has been redesigned in order to improve this robot's function. The new controller system used AT89S52 microcontroller which has wire connected to the robot hand. A function has been added with this controller to improve the system of controlling and becomes better than the previous system (only manually). The functions of the new system include three mo

... Show More
View Publication
Scopus Crossref