Preferred Language
Articles
/
HBhA5ZQBVTCNdQwC4yLn
Does preoperative magnetic resonant cholangiopancreatography (MRCP), improve the safety of laparoscopic cholecystectomy?
...Show More Authors
<bold>ABSTRACT</bold> <sec> <title>Background:

Magnetic resonance cholangiopancreatography (MRCP) is a non-invasive imaging test with excellent overall sensitivity and specificity for demonstrating the level and the presence of a biliary obstruction. MRCP has emerged as an accurate, diagnostic modality for investigating the biliary and pancreatic duct. In some cases, it has been recommended that preoperative MRCP is a good choice for the detection of CBD stones.

Aim:

The aim of the study is to assess the value of preoperative MRCP on the safety of laparoscopic cholecystectomy.

Methods:

The randomized study was carried out on 100 patients aged 16–65 years, admitted in Baghdad Teaching Hospital between 2013 and 2015. Laparoscopic cholecystectomy was performed for them. 45 patients had preoperative MRCP followed by conventional laparoscopic cholecystectomy, while 55 patients underwent only laparoscopic cholecystectomy. The findings of the two groups were compared.

Results:

In the first group: pre-operative MRCP screening exposed clinically silent CBD stones in 2 patients (4.44%), while one patient (2.22%) had accessory cystic duct and another one had an abnormal insertion of cystic duct (2.22%). In the second group, 4 patients had postoperative complications (P < 0.05): residual stones, postoperative bile leak, jaundice and pancreatitis.

Highlights:
Scopus Crossref
View Publication
Publication Date
Sun Jul 30 2023
Journal Name
Pakistan Heart Journal
Evaluation of nurses Practice toward Children Safety Post Cardiac Catheterization Procedure
...Show More Authors

Publication Date
Wed Sep 01 2004
Journal Name
Faculty Of Engineering/mustansiriyah University
Studying and Analyzing Actual Safety Situation of Construction Factories in Iraq
...Show More Authors

Safety programmes are considered one of the means to protect workers from different accidents and injuries and also to protect all assets including machines equipment and various materials. In spite of world state interests in occupational safety, this subject didn't get the required attention by senior staff of management at most of our country construction factories and the application of safety programmes still limited and in active. In order to a achieve the goal of the study, scientific method has been pursued to obtain the necessary information related to this study through tours to related companies and their construction factories and review literature that deal with occupational safety subject and their programmes and cost, in a

... Show More
Publication Date
Sat Jun 07 2025
Journal Name
Al-nahrain Journal For Engineering Sciences
The Effect of Magnetic Abrasive Finishing on the Flat Surface for Ferromagnetic and non-Ferromagnetic materials
...Show More Authors

Magnetic Abrasive Finishing (MAF) is an advanced finishing method, which improves the quality of surfaces and performance of the products. The finishing technology for flat surfaces by MAF method is very economical in manufacturing fields an electromagnetic inductor was designed and manufactured for flat surface finishing formed in vertical milling machine. Magnetic abrasive powder was also produced under controlled condition. There are various parameters, such as the coil current, working gap, the volume of powder portion and feed rate, that are known to have a large impact on surface quality. This paper describes how Taguchi design of experiments is applied to find out important parameters influencing the surface quality generated during

... Show More
View Publication
Publication Date
Sun Mar 03 2013
Journal Name
Baghdad Science Journal
Effect of Magnetic Water Treatment on Prevention of CaCO3 Scales
...Show More Authors

Permanent magnets of different intensities were used to investigate the effect of a magnetic field in the process of preventing deposits of calcium carbonate. The magnets were fixed on the water line from the tap outside. Then heating a sample of this water in flasks and measuring the amount of sediment in a manner weighted differences. These experiments comprise to the change of the velocity of water flow, which amounted to (0.5, 0.75, 1) m/sec through the magnetic fields that are of magnetic strength (2200, 6000, 9250, 11000) Gauss, and conduct measurements, tests and compare them with those obtained from the use of ordinary water.The results showed the effectiveness of magnetic treatment in reducing the rate of deposition of calcium carb

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Aip Conference Proceedings
A study of the safety and security conditions followed in the X-ray clinics in the Al-Amiriya-Baghdad
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue Dec 06 2011
Journal Name
Journal Of Planner And Development
Human Resources Investment as an Introduction to improve the efficiency & activity of workers in E – Government
...Show More Authors

The human resources are considered to be the main pillar of the organizations , economic development and the foundation of moving wheels of individual growth. This is considered as the basic tasks for any productive and economic activity . The investment of the human resources is the economic pillar of production , but the most important element of the production . This research tried to access the method of resource investment and to identify the problems and training as key element in establishment of E –government . A questionnaire document have been distributed to the workers at different levels in the colleges and institutes. The research concluded the necessity of job description , continuous training of the workers , usi

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 29 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Different Magnetic Fields on The Relative Efficiency and The Energy Resolution of Nai(TI) Detectors
...Show More Authors

The effect of different magnetic Jiel ds on the Nal(Tl) scintillation detector of (3"x3") and (1.5"x1.5")   sizes was studies, using the radioactive source Cs-137.

Two type:; of coils (A,B)  were used to produce the magnetic fields. The coil "A" is cylindrical of "9cm" diameter and "9cm" length , and of

2500 turns.

The measurements were taken in two positions ;the first when the crystal inside the coil ,and the second, the PMT inside the coil . The range of the magnetic field was (0.35,0.61,0.84,1.1 1,1.37,1.62,1.87 and

2.12) mT.

The coil "D" consists of two circular and parallel coils of "12 em" distance between them and of "18.5 em" diameter of each other and of "125" turns. rive &

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 01 2022
Journal Name
Process Safety And Environmental Protection
Safety and health management response to COVID-19 in the construction industry: A perspective of fieldworkers
...Show More Authors

View Publication
Scopus (50)
Crossref (48)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Advances In The Theory Of Nonlinear Analysis And Its Application
The Influence of the Magnetic Domain on The Peristaltic Motion of The Non-Newtonian Fluid in A Curved Tube
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
Step-up protocol gonadotrophin versus laparoscopic ovarian drilling in clomiphene citrate resistant PCOS infertile women in two Iraqi hospitals
...Show More Authors

Background: Polycystic ovarian syndrome is a common endocrine disorder affecting 6-10% of women of reproductive age and the most common cause of anovulatory infertility. Objective: The aim of the study was to compare the effectiveness, side effects and outcomes of step-up gonadotrophin protocol versus laparoscopic ovarian diathermy (LOD) in infertile patients with clomiphene citrate resistant polycystic ovary syndrome. Methods:  The sample included women who attended our infertility clinic at Al-Elwiya Maternity Teaching Hospital and Kamal Al-Samarraee for Infertility and IVF Hospital in Baghdad/ Iraq from November 2013 to November 2014.    Eighty cases of infertile women with polycystic ovarian syndrome who failed t

... Show More
Crossref (1)
Crossref