Geotechnical characterization of the sites has been investigated with the collection of borehole data from different sources. Using the data, grain size distribution curves have been developed to understand the particle size distribution of the alluvium present. These curves were further used for preliminary assessment of liquefiable areas. From geotechnical characterization, it has been observed that the soil profile in the two sites is dominated by sand and silty sand.Seed and Idriss (1971) approachhas been usedevaluatethe liquefaction potentialbydeterminationof the relation between the maximum ground acceleration (a max/g) valuesdue to an earthquake and the relative density of a sand deposit in the field. The results reveal that the study area will be subjected to occurrence of liquefaction under an earthquake of maximum ground acceleration of 0.1 g when the soil is loose with a relative density between (25-40) % in Kerbala city.Design chartswere obtained for determination of liquefaction potentialin any layer with knowingthe field relative densityand the value of the maximum ground surface acceleration.
Background: The Andrews’ six keys of normal occlusion contribute individually and collectively to the total scheme of occlusion and, therefore, are viewed as essential to successful orthodontic treatment. The present research aims to evaluate the presence of the parameters of the Andrews’ Six Keys of normal occlusion in a sample of 100 Iraqi adults with complete permanent dentition and clinically acceptable normal occlusion (Angle’s Class I) in Baghdad city. Their age range 18-25 years (60 males and 40 females). Materials and methods: Each patient was subjected to clinical examination and then study cast models were made, with their occlusal records. The measuring tools that have been used involved: Three-dimensional goniometer to me
... Show MoreThe aim of this study was to evaluate the effects of noise exposure in certain residential districts in Fallujah city. Twenty-nine stations were selected and divided into two groups; the first group was located 50 to 100 metres from the main streets (quiet areas), whilst the second was located directly on the main streets. Noise levels were measured at a rate of three readings per station for different time periods for approximately sixty days in the year 2020. Mean values were taken in both the morning and evening using a portable sound level meter (Auto range, RS-232). The highest noise level was measured at Alforkan station for the morning reading (83.8 dB) within the second group, while the lowest noise level
... Show MoreRepeated blood transfusion in beta thalassemia major patients may lead to peroxidative tissue injury by secondary iron overload. In the present study, 100 patients(50 male+50 female) with beta thalassemia major patients with age (5-20) years and 60 healthy control were included during their attendance at Abin Al_Baladi hospital in Baghdad. Malondialdehyde ,Superoxide Dismutase and Vitamin E, were measured by using kits.The results showed A highly significant (p<0.01)increase in the levels of Malondialdehyde and Superoxide Dismutase, whereas, significant p(<0.01)decrease in the levels of vitamin-E, This suggest that oxidative stress and reduced antioxidant defense mechanism play an important role in pathogenesis of beta thalassemia
... Show MoreTwo different approaches, univariate and multivariate (simplex method), have been used to obtain the optimum conditions for the quantitative Spectrophotometric determination of Eu3+ using Solochrome violet RS (3-Hydroxy-4-(2-hydroxy phenyl azo) naphthalene -1sulfonic acid) (SVRS) as a chromogenic reagent. The investigation shows that Eu3+ ion forms a wine-red complex with SVRS in alkaline buffer solution having a maximum absorbance at 464 nm against reagent blank. Calibration graphs obtained under univariate and simplex were found to be linear in the range of (0.30-8.0) µg/ml with detection limit 0.061µg/ml and molar absorptivity of 9877.66 L/mol.cm and (0.40-10.0)µg/ml with
... Show MoreThe aim of this work is to determine the uranium concentration in soil samples
taken from the north, south, east, west and center of the city of Baghdad and
measure its impact on the rate of cell division for non-smokers peoples and living in
those areas and that between the ages 25-30 year.
The uranium concentration in the samples determined by using CR-39 track
detector . As calculated for the ten samples of each site when irradiated by thermal
neutrons from the (Am - Be) source with flux (5x 103 n S-1cm-2), the concentration
values were calculated by a comparison with standard geological samples. The
results indicate that the extent of the concentration of uranium in the soil north and
east of Baghdad was 12
Thyroid hormones, triiodothyronine (T3) and thyroxin (T4) play an important role in growth, development, and physiology of the kidney. The kidney has a central role in metabolism and clearance of these hormones as well as thyroid – stimulating hormone (TSH). Chronic renal failure (CRF) is a state of irreversible deceleration in renal function results in alterations in internal milieu, which affects the synthesis and secretory rate of hormones. To evaluate the thyroid hormone levels in non-dialyzed patients with chronic renal failure (CRF); 24 patients with CRF aged 30-70 years, mean±S.d. (48.458 ± 13.569) and 48 healthy volunteers who served as controls aged 30-70 years (43.104 ± 12.387) were studied for their thyroid function status u
... Show MoreIodine-131 has become an essential radionuclide used in nuclear medicine for clinical and research purposes. The increase use of this radionuclide in medicine for diagnostic and treatment of thyroid diseases creates a demand to obtain a feasible methodology for occupational or accidental monitoring of internal contamination. In this study, two techniques were employed to find an appropriate one of in vivo bioassay for evaluating Iodine-131 body content. A scanning Whole Body Counter (WBC) equipped with 6NaI (Tl) scintillation detector, an anthropomorphic phantom and point source were used. The results showed that the counter sensitivity, as a first approach (conventional method), had a logarithmic and significant correlation w
... Show MoreThe aim of this study was extraction of jojoba oil using different solvents. A mixture of waterhexane and water-ethanol are used as solvents to extract jojoba oil in a batch extraction process and compared with a pure solvent extraction process. The effects of particle size of crushed seeds, solvent-to-water ratio and time on jojoba oil extraction were investigated. The best recovery of oil was obtained at the boiling temperature of the solvent and four hour of extraction time. When seed particle size was 0.45 mm and a pure ethanol was used (45% yield of oil extraction), whereas, it was 40% yield of oil at 25% water-hexane mixture. It was revealed that the water-ethanol and water-hexane mixtures have an effect on the oil extraction yield. T
... Show MoreIn the present study, a pressure drop technique was used to identify the phase inversion point of oil-in-water to water-in-oil flows through a horizontal pipe and to study the effect of additives (nanoparticles, cationic surfactant and blend nanoparticles-surfactant) on the critical dispersed volume fraction (phase inversion point). The measurements were carried for mixture velocity ranges from 0.8 m/sec to 2.3 m/sec. The results showed that at low mixture velocity 0.8 and 1 m/sec there is no effect of additives and velocity on phase inversion point, while at high mixture velocities the phase inversion point for nanoparticles and blend (nanoparticles/surfactant) systems was delayed (postponed) to a higher value of the dispers
... Show MoreSediment accumulated in sewers is a major concern source as it induces numerous operational and environmental problems. For instance, during wet weather flow, the re-suspension of this sediment accompanied by the combined sewer overflow may cause huge pollutant load to the receiving water body. The characteristics of the sewer sediment are important as it shapes its behaviour and determines the extent of the pollution load. In this paper, an investigation of sewer sediment and its characterization is done for a case study in Baghdad city. Sediment depth covers more than 50% of the sewer cross-sectional area; several operational causes are comprised to cause this huge depths of sediment depositions. The testing and analysis of the s
... Show More