Background: Lumbar disc degeneration (LDD) is a common musculoskeletal disorder that frequently causes low back pain (LBP). In addition to the discomfort of lower back pain, it can accompany pain in one or both legs. The lumbar spine and sacrum, consisting of five vertebrae and one bone, determine the spine's balance. Microelements are essential in bone metabolism and are associated with the prevention of osteoporosis and the alleviation of musculoskeletal pain. Objectives: To examine the correlation between lumbar spinal surgery and the concentrations of microelements, namely zinc and copper. Methods: A case-control study was conducted in Ghazi Al-Hariri Hospital in Baghdad, Iraq, during the period from October 2023 to January 2024. The study included 120 participants ranging in age from 18 to 70 years. Sixty participants underwent lumbar spine surgery and were diagnosed using X-rays or MRI scans. The other 60 were healthy controls. The zinc (Zn) and copper (Cu) levels in the blood were determined using an atomic absorption spectrometer. The body mass index (BMI) was determined using the formula: BMIg/m2 = weight/height2. Results: The patients had a lower mean zinc level (57.3 ± 14.56 Mmol/L) and a higher mean copper level (106.6 ± 39.41 Mmol/L) in comparison to healthy controls (96.4 ± 17.38 Mmol/L) and (61.0 ± 9.53 Mmol/L), respectively There was a weak relationship and a significant correlation between copper and zinc (r = -0.2). A very strong relationship and a significant correlation between copper and Cu / Zn ratio (r = 0.85) while zinc had a significant very strong correlation relationship with Cu / Zn ratio (r = -0.7) in patients. Conclusion: The present study underscores the noteworthy association between microelements (Cu, Zn) and degenerative lumbar discs, underscoring the significance of pre-operative evaluation in achieving the best possible surgical results. The study has demonstrated the utility of measuring serum zinc level and copper level, especially their link with lumbar disc degeneration (LDD) markers of patients undergoing lumbar spinal surgery.
The current study aimed the syntheses and characterizations of Gold nanoparticles (Au NPs) using a laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the
... Show MoreTransition metal complexes of Y(III), La(III) and Rh(III) with azo dye 2,4-dimethyl-6- (4-nitro-phenylazo)-phenol derived from 4-nitroaniline and 2,4-dimethylphenol were synthesized. Characterization of these compounds has been done on the basis of elemental analysis, electronic data, FT-IR,UV-Vis and 1HNMR, as well as conductivity measurements. The nature of the complexes formed were studies following the mole ratio and continuous variation methods, Beer's law obeyed over a concentration range (1x10-4- 3x10-4). High molar absorbtivity of the complex solutions were observed. From the analytical data, the stoichiomerty of the complexes has been found to be 1:3 (Metal:ligand). On the basis of Physicochemical data octahedral geometries were as
... Show MoreThis paper presents a comparison study on thermal performance conic cut twist tape inserts in laminar flow of nanofluids through a constant heat fluxed tube. Three tape configurations, namely, quadrant cut twisted tape (QCT), parabolic half cut twisted tape (PCT), and triangular cut twisted (VCT) of twist ratio= 2.93 and cut depth= 0.5 cm were used with 1% and 2% volume concentration of SiO2/water and TiO
... Show Morefication of benzaldehyde (C6H5CHO) and O- amino aniline O-C6H4(NH2)2 in ethanol with 8- Hydroxyquinoline (8HQ) . Formed compounds were acquired of 1:1:2 molar proportion reactions for metal ions and ligands (L) and 2(8HQ) during reaction for MCl2 .nH2O salt products complexes conformable into the forms [M(L)(8HQ)2] ,where M = Mn(II),Co(II) and Ni(II). Whole the compounds were identified during the basis of their; FT-IR and U.V spectrum, melting point, molar conduct, identify of the percentage from the metal at the complexes via flame (AAS), C, H and N content of the Schiff base (L) and metal complexes were analysis and magnetic susceptibility menstruations. A hexagonal coordinated metal complexes were proposed to the separated complexes of
... Show MoreNew complexes of first series of transition metals with P-amino benzene dithiocarbamate of the general formula [M(PABdtc)2] and [ M(PABdtc)2(L)n] M=Fe( ІІ ),Co( ІІ ),Ni( ІІ ) ,Cu(ІІ) and Zn (ІІ). PABdtc = Paraamino benzene dithiocarbamate ,n=2 when L= Py,ɣ-Pic,iso qunoline ,3,5lutidine n=1when L=1,10-phenanthroline, en, 2,-2bipy.and the type(R)4N[Ni(PABdtc)3] R= methyl, ethyl are prepared. Physico chemical characterization of these complexes was applied using magnetic susceptibility measurements, molar conductance , Infrared and electronic spectra, Metal content measurements, molar conductance indicate complexes of the type [M(PABdtc)2] and [M(PABdtc)2(L)n] are non-electrolyte
... Show MoreAbstract: Microfluidic devices present unique advantages for the development of efficient drug assay and screening. The microfluidic platforms might offer a more rapid and cost-effective alternative. Fluids are confined in devices that have a significant dimension on the micrometer scale. Due to this extreme confinement, the volumes used for drug assays are tiny (milliliters to femtoliters).
In this research, a microfluidic chip consists of micro-channels carved on substrate materials built by using Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters have influence on the width, depth, roughness of the chip. In order to have regular
... Show More